The operator must be instructed in the correct handling of the this type of waste water. system. aquadetox international GmbH accepts no liability of any kind for The operator must provide verification of their capability to op- damage or operational malfunctions resulting from inadequate erate the system.
Page 3
Hazard levels DANGER Danger due to harmful substances DANGER ● Danger to health from contact with dust and microbiological con- Indication of an imminent threat of danger that will lead to se- taminants. vere injuries or even death. WARNING Wear a suitable dust protection mask and gloves when replacing ● ...
System description Control head (used from 12/2018) Control cabinet "-" button: The down arrow button is used for decreasing a value. "+" button: The up arrow button is used for increasing a value. "CLOCK" button: This button is used for setting the time. The value is increased / reduced using the arrow buttons.
Page 5
Version options Underground structure BCi-2 SF 2 Compressed air (on site) Biological stage 1 Fresh water (on site) Biological stage 2 Biological stage 2 Processed water Biological stage 1 Aerator Sludge trap 2 Control cabinet Sludge trap 1 Supply Sludge trap 1 Sludge trap 2 English...
Page 6
Above ground structure BSV-1 SF Compressed air (on site) Processed water Fresh water (on site) Aerator Biological stage 2 Control cabinet Biological stage 1 Pumping station Sludge trap Waste water supply Sludge trap Pumping station Biological stage 1 Biological stage 2 English...
OptimusBioSaver2in1 Operation Fresh water (on site) Compressed air (on site) Note Biological stage Materials such as e.g. soldering flux, sealing hemp etc. can enter Optimus the interior of the pipes when installing pipelines on-site. These Sludge trap materials can clog the fittings attached these pipelines during the first weeks of operation.
Page 8
Operational log book "Manufacturer" button: Change to the "Manufacturer Code" screen Note "Service" button: Change to the "Service Code" screen In the case of an official inspection and during all customer ser- "QR-Code" display of the service number (the service tele- vice activities, as the operator you are obliged to hand the oper- phone number can be entered by the service technician dur- ational log book over to the authorised persons.
Page 9
"System manufacturer" screen "System Diagram" screen Touching the "System Manufacturer" button in the main window Touching the "System Diagram" button displays the "System Di- displays the address and contact information of the system man- agram" screen allowing selection of individual system compo- ufacturer.
Page 10
Pre-treatment / sludge trap, "Variant 1 / 1 Pre-treatment stage" screen Touching the "Pre-treatment 1" button displays the "Variant 1 / 1 Pre-treatment stage" screen. "Pumping Station" button: Change to upstream system com- ponents "Pre-treatment 2" button: Change to downstream system components Pre-treatment / sludge trap, "Variant 2 / 2 Pre-treatment stages"...
Page 11
Biological stage "Variant 1 / 1 biological stage" screen "Waste Water Pumping Station" screen Touching the "Biology 1" button displays the "Variant 1 / Touching the "Pumping Station" button displays the "Waste Water 1 biological stage" screen. Pumping Station" screen. ...
Page 12
"Post-treatment" screen "Pressure Increase Pump" button: Change to the "Aerator / Pumps / Valve fittings" screen (see Chapter The "Aerator / Touching the "BioSaver" button displays the "Post-treatment" Pumps / Valve fittings" screen) screen The "Aerator / Pumps / Valve fittings" screen ATTENTION Deactivated safety devices The system is manually switched from Manual mode to Automat-...
Page 13
"Level display" screen "Fresh water mode" button: Touching the button activates fresh water operation in the processed water reservoir (button is high- The level displays on the screen are for information only. The values lighted in yellow). Touching the button again deactivates fresh can only be changed by the service technician (Service code).
Page 14
"Backwashing" screen "Message" screen Touching the "Backwashing" button displays the "Backwashing" Touching the "Information query" button displays the "Messages" screen. window containing the current error messages and information messages (see also the Chapter Help with Troubleshooting guide, Chapter Information messages and Chapter Error mes- sages).
Error message and information message history Cleaning, service and inspection schedules Touching the "List button displays the "Messages" window con- Note taining the history of error messages and information messages This overview is only intended as an aid and makes no claim to (see also the Chapter Help with , Chapter and Chapter Error completeness, especially in the case of customer-specific solu- ®...
Page 16
Sludge trap servicing Period Activity Person- Check the sludge trap and pumping station (option) together. The sludge level in the sludge traps must be regularly checked 5-year Removal of a sample from the pro- Custom- using a measuring disc (inspection set for separating systems). general cessed water tank and checking of the er service...
Page 17
Post-treatment servicing Reservoir tank servicing Note Note No processed water for the washing process is provided during The inlet is blocked during cleaning. Cleaning may only be per- the flushing period. Cleaning may only be performed when no formed when no washing operations are being performed. Deposits form in the processed water tank during operation.
2. Clean the inner walls of the tank with a water jet after fully 4. Lift the intake air filter and clean with compressed air from the draining the processed water tank. inside to the outside. Note 5. Fit the protective hood and fasten with the wing nuts. 6.
Page 19
Information messages Information message Cause Fresh water mode active The Fresh water mode is active. Information message Cause Battery weak The charge state of the battery is less Min. tank level The tank has reached its minimum fill- than 30 %. ing level.
2011/65/EU 2015/863 aquadetox international GmbH herewith confirms that according to current knowledge all products sold by aquadetox international GmbH (if not expressly marked) comply with the directive 2011/ 65/EU. These products meet the current requirements of the Ro- HS directive for all 7 named materials: Max. 0.1% of weight in ho-...
Need help?
Do you have a question about the BioSaver- System / WRB Bio Series and is the answer not in the manual?
Questions and answers