Receptacle removal tool

Advertisement

Operating Instruction
RECEPTACLE REMOVAL TOOL (FZWZ)
Step-by-step-Instruction
1.
Make sure that the handle is locked!
Screw the tool clockwise into the mounted receptacle
until a few turns are cut. This is the case when the
screwing in becomes stiffer or the guiding sleeve (03)
touches the module.
2.
Release the lock: Turn the entire tool back slightly
counterclockwise so that the lock can be released
more easily. Then hold the flattened surfaces (mar-
ked red) and turn the handle counterclockwise.
3.
Continue turning the tool clockwise. The receptacle
pulls upwards from the mounting plate, into the
guiding sleeve and can be removed.
4. Remove the receptacle from the tool with the nipper
by screwing it counterclockwise from the tool. The
sleeve can be bent by 30°- 90°.
5.
For reuse, the thread insert must be screwed all the
way down so that the lock can be set.
Edition 08/2018. All rights reserved.
www.feinmetall.com
Lock it first!