THE LEVEL OF HYSTERESIS
The level of hysteresis indicates the amount of increase
in the flow above the alarm level required to stop the
alarm automatically. The default setting is 0,3 l/min. In
the default setting mode, the flow alarm will be activated
when the flow decreases below 0,5 l/min for more
than five seconds. It will be deactivated when the flow
increases by more than 0,8 l/min.

4.3 Changing the default settings

To change the default settings, open the plastic case of
the controller.
Turn the power off using the on/off switch prior to
opening the case!
Proceed with great caution!
Behind the controller's circuit card there are two
programming buttons that can be used to change the
default settings. See the picture.
14
-
+
Pulse rate
The default settings can be changed by obeying the
following instruction:
1. Press both programming buttons and hold them down.
Switch on the controller by using the on/off switch.
2. Set new values using the buttons of the panel on the
front.
Flow: the pulse rate decreases
Trip: the pulse rate increases
Total: the alarm level decreases
Reset: the alarm level increases
Shift: the hysteresis decreases
Pump: the hysteresis increases
3. Release the programming buttons.
-
+
-
+
Alarm level
Hysteresis
15