DIGITAL ELECTRONIC FEVER THERMOMETER
INSTRUCTIONS FOR USE - Please read carefully

Features

Easy to read digital liquid crystal display (LCD)
Temperatures can be taken under arm (axillary use) or under the tongue (oral use)
Auto shut-off after approximately 10 minutes of inactivity
Water proof for easy cleaning
ABS resin body presents fewer hazards than mercury glass thermometers
Low battery Indicator
Fast and accurate- 10 second read time after thermometer reaches a stable temperature reading
Thermometer's Measurement Range: 32.0~42.9°C or 90.0~109.9°F
Resolution: 0.1 °C /°F
Accuracy: ±0.1°C, 35.5~42.0°C (± 0.2°F, 95.9~107.6°F), ±0.2°C below 35.5°C or over 42.0°C
(±0.4°F below 95.9°F or over 107.6°F)
Battery: LR 41- Alkaline button cell battery (0.0% Hg)
Beeper: Approximately 10 seconds once temperature is stabled.
Memory: Built-in memory enabling display of previously measured value.
°F/°C Change: While unit is off, press & hold On/Off button for approximately 4 seconds to toggle
between °F/°C. Release the button once desired setting is established
Working Conditions: Relative Humidity: 15% ~ 95%, Temperature: 5~40°C
Storage Conditions: Relative Humidity: 15% ~ 95%, Temperature:-20~55°C

Battery Replacement

1.
Replace battery when appears in lower right corner of LCD display.
2.
Pull battery cover off (located at opposite end of probe).
3.
Gently pull out plastic circuit board with battery chamber approximately 1 cm.
4.
Use a small instrument like a toothpick to remove battery. Avoid using a sharp metal object.
5.
Place a battery in the chamber with positive side (+) facing up.
6.
Slide battery chamber back into place and put the cover on.
Warning: Discard old battery carefully. Do not dispose of the battery in a fire. It may explode.
Caution:
Read instructions completely before using digital thermometer
Keep out of reach of children and pets
Thermometer cap and battery may be fatal if swallowed. In this occurs, seek medical attention
immediately
Do not use thermometer in ear. Designed for oral and axillary readings only
Do not place thermometer battery near extreme heat
Note: Use of probe cover may result in 0.1⁰C (0.2⁰F) discrepancy from actual temperature
Normal body temperature varies with age, time of day, physical activity, hormonal and
environmental factors
Temperature in the late afternoon or evening will usually be 0.6⁰C (1.0⁰F) higher than the
morning temperature
It is recommended to check the performance of the thermometer every 2 years. Do not
disassemble.
Performance of thermometer may be affected if the following occurs:
Instructions for use
1.
Disinfect the probe with isopropyl (rubbing) alcohol – DO NOT boil probe.
2.
Press the on/off button next to LCD display. A tone will sound as the screen displays
followed by last recorded temperature. Note: If the measured or room temperature is less than
90⁰F or 32⁰C, the LCD will display Lo, if the measured or room temperature is higher than
109.9⁰F or 42.9⁰C, the LCD will display Hi.
3.
Position thermometer in desired location (mouth or armpit).
Oral use: Place thermometer under the tongue as indicated with a check
mark. Close mouth and breathe through the nose. Normal temperature should
be 36.3⁰C to 37.2⁰C (97.3⁰F to 99.1⁰F).
Armpit use: Wipe armpit dry. Place probe in armpit and keep arm pressed firmly at side. Normal
temperature should be 35.8⁰C to 36.8⁰C (96.4⁰F to 98.2⁰F).
4.
The degree sign flashes on the LCD while the thermometer is reading your temp.10 seconds
after thermometer reaches a stable temperature reading, the flashing will stop and an alarm will
beep. The measured reading will appear on the LCD. The displayed reading will not change
when the thermometer is removed from its testing position. Note: normal alarm: Bi---Bi---Bi and
high temperature alarm: Bi-Bi-Bi ---- Bi-Bi-Bi ---- Bi-Bi-Bi.
5.
To prolong battery life, turn unit off after testing. If no action is taken, unit will automatically shut
off after approximately 10 minutes.
For optimal product performance, it is recommended to replace thermometers after 5 years of usage.
Questions? 1.888.475.2500 www.PharmaSystems.com
Manufactured by / Produit par : PharmaSystems Inc. 151 Telson Road, Markham, Ontario, Canada L3R 1E7
Made in China / Fabriqué en Chine
Storage or operation outside stated temperature and humidity range
Mechanical shock
Electromagnetic interferences (ie. microwave, cell phones)
R0516

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS720 and is the answer not in the manual?

Questions and answers

Summary of Contents for PharmaSystems PS720

  • Page 1 For optimal product performance, it is recommended to replace thermometers after 5 years of usage. R0516 Questions? 1.888.475.2500 www.PharmaSystems.com Manufactured by / Produit par : PharmaSystems Inc. 151 Telson Road, Markham, Ontario, Canada L3R 1E7 Made in China / Fabriqué en Chine...
  • Page 2 Pour une performance optimale, il est recommandé de remplacer les thermomètres après 5 ans d’utilisation. R0516 Questions? 1.888.475.2500 www.PharmaSystems.com Manufactured by / Produit par : PharmaSystems Inc. 151 Telson Road, Markham, Ontario, Canada L3R 1E7 Made in China / Fabriqué en Chine...

This manual is also suitable for:

Ps730Ps770

Table of Contents