Advertisement

Quick Links

"Lift-Complex DS", OOO
Intercom unit 7.2
OPERATIONS MANUAL
LNGS.465213.270.500 OM
(Edition 7)
Novosibirsk 2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Intercom unit 7.2 and is the answer not in the manual?

Questions and answers

Summary of Contents for LKDS Intercom unit 7.2

  • Page 1 “Lift-Complex DS”, OOO Intercom unit 7.2 OPERATIONS MANUAL LNGS.465213.270.500 OM (Edition 7) Novosibirsk 2018...
  • Page 2: Table Of Contents

    Table of contents 1. Description and operation ..................4 1.1. Purpose ......................4 1.2. Terms of Use ....................4 1.3. Specifications ....................4 1.4. Content of delivery ..................4 1.5. Main functions ....................4 1.6. IU 7.2 design....................4 1.7. IU 7.2 operation .................... 7 1.7.1.
  • Page 3 IU 7.2 Operations manual LNGS.465213.270.500 OM This manual is intended for getting familiar with Intercom unit 7.2 of the Lift Monitoring and Diagnostics System; understanding its performance and operating rules (usage, transportation, storage and maintenance). The manual covers Intercom units 7.2 of the following options: LNGS.465213.270.500;...
  • Page 4: Description And Operation

    1.3.9. Max distance to Landing Intercom and indicator should not exceed 5m. 1.4. Content of delivery 1.4.1. The content of delivery of option LNGS.465213.270.500-02 includes: - Intercom unit 7.2 LNGS.465213.270.500 — 1 pc.; - Wiring harness LNGS.465213.270.060 — 1pc.; - Holder LNGS.465213.270.002-01 – 1pc.;...
  • Page 5 IU 7.2 Operations manual LNGS.465213.270.500 OM - Backhighlited “CALL” button; - microphone; - loudspeaker. "MODE" "Wi-Fi" "CALL" button "CAN" "PIT" "CABIN" Mode setting "TRM" jumper Fig. 1. Appearance of IU 7.2, sockets, controls and indicators Table 1. Meaning of indicators Name Status Colour...
  • Page 6 IU 7.2 Operations manual LNGS.465213.270.500 OM CAN bus data transmission "CAN" Green CAN bus connection established not lit No CAN bus connection established white Voice connection to dispatch is available blinking white Voice connection to LU is available blinking "CALL" (series of 2 white Dispatch “CALL”...
  • Page 7: Iu 7.2 Operation

    IU 7.2 Operations manual LNGS.465213.270.500 OM YLED are alternately appear for a period of 2 seconds. 1.6.4. To balance the load of CAN bus terminators are to be connected on both ends of the bus. This performed by using “TRM” jumper on the ending device, in other cases the jumper should be left open.
  • Page 8: Making Internal Network

    IU 7.2 Operations manual LNGS.465213.270.500 OM The address is assigned with the help of jumpers. Green light of the “Mode” LED means the “CABIN” mode is used where as Red light is assigned to “PIT” mode. 2.1.2.Setting contact type of “CALL” button and “FIRE” input Upon delivery, a normally open contact type is set.
  • Page 9: Connecting Internal Battery

    IU 7.2 Operations manual LNGS.465213.270.500 OM Fig 3.Internal network architecture 2.3. Connecting internal battery IU 7.2 has built in accumulator battery (Type 14500, 750mA/H). To connect the battery to IU circuit, close pins 4 and 5 of XP1as shown on Fig.4. LNGS.465213.270.500;...
  • Page 10: Wiring Iu 7.2

    IU 7.2 Operations manual LNGS.465213.270.500 OM Install jumper to connect battery Fig.4. Connecting acc.battery to IU’s internal circuit 2.4. Wiring IU 7.2 2.4.1. Make wiring as prescribed in LNGS.468223.270.500 E5 (see APPENDIX 3). 2.4.2. Overall and connecting dimensions are shown in APPENDIX 2. 3.
  • Page 11: Permanent Repair

    IU 7.2 Operations manual LNGS.465213.270.500 OM 4. PERMANENT REPAIR 4.1. The product is repaired by manufacturer during the warranty period. Service after warranty period is provided by a separate contract. 5. INSTALLATION IU 7.2 is a complex technical product, its use requires sufficient qualification of personnel for proper installation and start-up.
  • Page 12: Storage

    7. STORAGE 7.1. Intercom Unit 7.2 of the Lift Monitoring & Diagnostics System can be stored up to 6 months from the date of manufacturing. 7.2. Intercom Unit 7.2 in original packing must be stored in enclosed spaces with natural ventilation, without artificial climate regulators, where the humidity and temperature fluctuation is less than in open air, located in moderate/cold climatic region.
  • Page 13 IU 7.2 Operations manual LNGS.465213.270.500 OM Appendix 1 Intercom Unit 7.2 Overall and mounting size. LNGS.465213.270.500; LNGS.465213.270.500-01; Edition 07 LNGS.465213.270.500-02 Lift Monitoring and Diagnostics System 27.08.19 p. 13...
  • Page 14 IU 7.2 Operations manual LNGS.465213.270.500 OM Appendix 2 Intercom Unit 7.2. Wiring diagram. LNGS.465213.270.500 E5 LNGS.465213.270.500; LNGS.465213.270.500-01; Edition 07 LNGS.465213.270.500-02 Lift Monitoring and Diagnostics System 27.08.19 p. 14...
  • Page 15 “Default” button «YLED» Input «CALL» Input «FIRE» Input «GLED” Input «YLED” Intercom Unit 7.2 Correspondence of signals in the LMDS software to the input / output sensors LNGS.465213.270.500; LNGS.465213.270.500-01; Edition 07 LNGS.465213.270.500-02 Lift Monitoring and Diagnostics System 27.08.19 p. 15...
  • Page 16 IU 7.2 Operations manual LNGS.465213.270.500 OM Appendix 4 Description of structure files, contents of folders and settings available on the SD card included in the package: Negotiating device 7.2 LNGS.465213.270.500. Rev00 25.06.2016 1. Sound files SD_RIN Format of supported wav sound files and MP3. 2.
  • Page 17 IU 7.2 Operations manual LNGS.465213.270.500 OM ConfigLBPro program does not change the SD _ RIN configuration file located on the SD card. 4. SD_RIN configuration file The parameters used by the SD _ RIN are stored by default in the file “ Configrin . ini ”, which is located on the microSD card in the“...
  • Page 18 IU 7.2 Operations manual LNGS.465213.270.500 OM Daily schedule. The validity of the daily schedule is 1 day. Schedule controls the overall volume of the SD RIN and applies to all events. The overall volume complements the personal volume of each event. During the day and stands 8 periods to personally set the overall volume level SD _ RIN.
  • Page 19 IU 7.2 Operations manual LNGS.465213.270.500 OM 075.wav 002.wav Ground floor 003.wav Second floor 004.wav Third floor 005.wav Third floor 006.wav Fifth floor 007.wav Sixth floor 008.wav Seventh Floor 009.wav Eighth Floor 010.wav Ninth floor 011.wav Tenth Floor 012.wav Eleventh floor 013.wav Twelfth floor 014.wav...
  • Page 20 IU 7.2 Operations manual LNGS.465213.270.500 OM 044.wav The forty third floor 045.wav Forty-fourth floor 046.wav 45th floor 047.wav 46th floor 048.wav 47th floor 049.wav Forty-eighth floor 050.wav The forty ninth floor 051.wav 50th floor 052.wav Fifty first floor 053.wav Fifty second floor 054.wav Fifty third floor 055.wav...
  • Page 21 IU 7.2 Operations manual LNGS.465213.270.500 OM 096.wav Parking, fifth level 097.wav Parking, level six 101.wav A restaurant 102.wav 103.wav Cafe 107.wav 104.wav Supermarket 105.wav Terrace 106.wav Pool 108.wav Main entrance 109.wav Exit zone 110.wav Hall 111.wav Reception desk 112.wav Arrival 113.wav Departure 114.wav...
  • Page 22 IU 7.2 Operations manual LNGS.465213.270.500 OM 155.wav Lawyer 158.wav Technical floor 174.wav The outside 175.wav Porch 176.wav Platform 5.3. Event «Background music», folder 98_MUSIC. This folder contains the albumX subfolders , where X = 0..31. The maximum number of folders can be 31, album 0 ..
  • Page 23 IU 7.2 Operations manual LNGS.465213.270.500 OM SWE - Swedish - Turkish - Ukranian LNGS.465213.270.500; LNGS.465213.270.500-01; Edition 07 LNGS.465213.270.500-02 Lift Monitoring and Diagnostics System 27.08.19 p. 23...