Advertisement

Quick Links

HUMMING PROBE pH Measurement system
Contents
Introduction .....................................................................................................................2
1.
1.1.
Product Introduction ...................................................................................................................... 2
1.2.
Safety Instructions .......................................................................................................................... 2
2.
Product Description ........................................................................................................2
2.1.
HUMMING PROBE pH Measurement System ................................................................................ 2
Product, Accessories and Function keys .......................................................................3
3.
3.1.
UX100 pH Measurement Meter ..................................................................................................... 3
3.2.
UH1: pH Test Strip Electrode .......................................................................................................... 3
3.3.
Strip Extended Connection Cable................................................................................................... 4
3.4.
Charging ......................................................................................................................................... 4
3.5.
Touch screen icon definition .......................................................................................................... 4
Main screen & Description .............................................................................................5
4.
UX-100 Setup .................................................................................................................6
5.
5.1.
Setup Menu and Function List ....................................................................................................... 6
5.2.
Measuring Mode Selection: ........................................................................................................... 8
Measuring pH ..................................................................................................................9
6.
6.1.
Strip Port Mode measuring procedure. ......................................................................................... 9
6.2.
Cable Socket Mode Measurement Procedure ............................................................................. 10
Stored data Reading and Editing ................................................................................. 12
7.
7.1.
Read or Edit Data .......................................................................................................................... 12
7.2.
USB Storage Mode to connect to PC ............................................................................................ 13
8.
Technical Data sheet .................................................................................................... 13
Warranty ........................................................................................................................ 14
9.
User Manual (V1.0)
1

Advertisement

Table of Contents
loading

Summary of Contents for UltraE HUMMING PROBE

  • Page 1: Table Of Contents

    Product Introduction ........................2 1.2. Safety Instructions .......................... 2 Product Description ......................2 2.1. HUMMING PROBE pH Measurement System ................2 Product, Accessories and Function keys ...............3 3.1. UX100 pH Measurement Meter ..................... 3 3.2. UH1: pH Test Strip Electrode ......................3 3.3.
  • Page 2: Introduction

    It is easy to use, free from calibration, convenient to store and carry. Measurement is just easy and quick.. The HUMMING PROBE pH measurement system is manufactured by UltraE Co., Ltd., ■ and sold by authorized dealers. If you have any questions or comments about our products, please call our company or contact your local distributor.
  • Page 3: Product, Accessories And Function Keys

    3. Product, Accessories and Function keys 3.1. UX100 pH Measurement Meter Dual Mode Inspection Adapter Socket Power Button Strip Port USB/ Charging Port Front Side Back View Built-in Adjustable Stand Camera Light Adjustable Stand 3.2. UH1: pH Test Strip Electrode Vial (10 pcs/vial) pH Test Strip Electrode UH1 Note: The vial should...
  • Page 4: Strip Extended Connection Cable

    3.3. Strip Extended Connection Cable Strip Extended Plug connecting Adapter for pH test Strip electrode insert Connection to Meter socket strip electrode to method and Cable insert direction. 3.4. Charging UX100 rechargeable battery can be used for a few hours after fully charged. Plug the Charger into 100/240V AC power supply and connect to the Meter with micro USB Cable.
  • Page 5: Main Screen & Description

    4. Main screen & Description Switch on and enter main screen (press and hold the power switch for 2 seconds) Icon Touch icon description Mode Switch: Icon : Date.Time Mode Switch Switch to Strip Port mode Battery Charging pH Reading Switch to Cable Indication Socket mode...
  • Page 6: Ux-100 Setup

    5. UX-100 Setup 5.1. Setup Menu and Function List Click to initiate setup menu Tab and slide the screen to move the menu up and down. Tick to automatically store pH reading when reaching stable state Custom storage pH data title Delete all data Power Saving mode Connect to computer...
  • Page 7 Operation Instructions Tick here and Data will be saved automatically reaching stable pH measuring. Click to enter the input page, you can input a title as the preset title of the pH storage record, press to confirm , or press to return to the previous screen.
  • Page 8: Measuring Mode Selection

    After downloading the new firmware FWUD.PACK and store it in UX100 , click here to update. Check firmware update at www.ultrae.com.tw. When the Update Firmware Options appears. For new firmware Press Yes to confirm update. It will be updated found, download it to...
  • Page 9: Measuring Ph

    6. Measuring pH 6.1. Strip Port Mode measuring procedure. (1) Turn on the meter (press the power switch for 2 seconds) , choose the Strip Port Mode. (2) Click the QR code Icon below the main screen. (3) The current Lot no. will display ( the number before Measurement # is the Lot no., the number after # shows the un- screen...
  • Page 10: Cable Socket Mode Measurement Procedure

    (9) Press the Inspect icon bubble icons will appear to indicate the status of measurement , 1 bubble (begin) to 5 bubbles (pH stable state) (10) When the pH stable state display, the pH measuring is done and the stable pH reading will display on screen.
  • Page 11 (5) Rescan: Align the “photo frame” with the QR code on the vial, and then press the scan icon scan. (6) Check the Lot no. (number before #) and press OK if correct. If not, press Rescan to rescan. (7) Take the test strip electrode out of the vial and close the vial instantly.
  • Page 12: Stored Data Reading And Editing

    7. Stored data Reading and Editing to enter data editing Mode 7.1. Read or Edit Data Tab and slide the screen to move the menu to enter data up and down. Editing Menu Tab a record to enter to enter text input page to input data editing page, text notes.
  • Page 13: Usb Storage Mode To Connect To Pc

    7.2. USB Storage Mode to connect to PC (1) Connect the Meter to computer with USB cable, then choose and enter the USB Storage Mode, run the file manager of the computer to find “UX100 DISK”. (2) Enter “UX100 DISK” root directory, UX100_UserManual.pdf can be found for download. (3) The directory “Data”...
  • Page 14: Warranty

    UltraE that are contradictory to the abovementioned guarantee conditions are void unless these are made in writing and signed by an authorized person. UltraE is not liable to users for any damages, either direct or indirect, relating to the ■ misuse of the products and accessories...

Table of Contents