Renovia Leva Manual

Renovia Leva Manual

Pelvic digital health system
Hide thumbs Also See for Leva:

Advertisement

Quick Links

Pelvic Digital Health System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Leva and is the answer not in the manual?

Questions and answers

Anna marie chwastiak
January 22, 2025

Where do I purchase replacement batteries for the wand and case used device …stopped but now having issues -device in excellent condition -not connecting to phone

1 comments:
Mr. Anderson
February 10, 2025

To purchase replacement batteries for the Renovia Leva device, contact Renovia at (833) 450-2914.

This answer is automatically generated

Summary of Contents for Renovia Leva

  • Page 1 Pelvic Digital Health System...
  • Page 2: Table Of Contents

    Table of Contents Read This First ....................3 Welcome to leva® ..................... 3 Indications for Use ..................5 Contraindications .................... 5 Warnings ......................5 Precautions ...................... 6 Getting Started ....................7 Smartphone Compatibility ................9 App Download ....................9 Device Registration ..................9 Pairing Your Device ....................
  • Page 3: Read This First

    Pelvic Digital Health System (leva PDHS) to ensure that your use of the device is safe and effective. As you begin to familiarize yourself with the leva PDHS, it is normal to have questions. If at any time you have questions or need assistance, contact the Renovia’s Women’s Center at (866) 735-8423.
  • Page 4 The leva PDHS operates on batteries located in the base of both the case and the probe. The leva PDHS is provided with a sturdy storage case. This case serves two purposes: it protects the device during storage and also serves as a communications bridge between your leva and your mobile phone (i.e.
  • Page 5: Indications For Use

    Always remove the leva probe after each training session and do not exceed 60 minutes of insertion, including during menstruation. Do not use the leva probe in any other place in your body. The leva...
  • Page 6: Precautions

    Do not have sexual intercourse while the leva probe is inserted. Do not insert the probe if there is any damage to any of the leva PDHS components. Keep the leva PDHS out of reach of children. If left unattended, the leva PDHS could prove to be a choking hazard to a child and could result in death.
  • Page 7: Getting Started

    Do not use oil or petroleum-based lubricants with the leva PDHS. Use water-based lubricants only. • Do not leave the leva PDHS in the sun, near an open fire, or in a hot parked car. Excessive or direct heat can damage the leva PDHS. •...
  • Page 9: Smartphone Compatibility

    Then follow the pairing process as indicated on the app by first selecting the “leva-02” device, then selecting “Connect leva.” The app will search for the leva-02 Bluetooth signal and when found will show the device ID. Once found select “proceed.” See below screenshots of the pairing process.
  • Page 11 App Features Renovia App has several screens that can be reached from the Dashboard. Renovia App Dashboard Practice Mode More Training Mode About You Tests Device Information Support Education Frequently Asked Questions (FAQs) Reminders Figure 1. Renovia App Screenshots...
  • Page 12: Inserting The Leva Probe

    PDHS. Insert the leva Probe. Hold the leva probe lightly by placing your thumb on the grip and your index and middle finger on the opposite side. Remember to keep the probe aligned with the raised line and logo facing forward.
  • Page 13 Before beginning your exercises, pull up your underwear up only enough to gently hold the leva in place. Try to stand in the same position, standing up straight, and wearing no shoes (or similar shoes) each time you do your exercises.
  • Page 14: Starting Your Session

    2.5 minutes. To access the Training mode, click on the large “+” button at the bottom of the screen. The app will remind you to always wash your hands and leva prior to use and will indicate how to insert the device.
  • Page 15: Removing The Leva Probe

    Training Mode. Your leva PDHS session history is automatically stored on the Renovia database and is available to you right from the Dashboard. You can view a shorter or longer period of progress time by selecting different timepoints...
  • Page 16: Technical Specifications

    Wash your leva probe with mild, warm soapy water, gently dry the device, and return the device to its storage case. Technical Specifications The leva PDHS uses 6 sensors to provide positional feedback on the shape and movement of your vagina as you perform pelvic floor muscle exercises.
  • Page 17: Expected Service Life

    Use the following instructions to ensure proper care and maintenance of your leva PDHS. Cleaning the Probe: To ensure hygienic safety, you should clean and dry your leva probe before and after each treatment session. • Clean the leva probe with mild, warm, soapy water.
  • Page 18: Radio Frequency Wireless Technology

    • Do not submerge the device in water or liquid. Cleaning the Case: Do not wash or submerge the leva case. If the case needs cleaning, wipe the case with a damp cloth. Radio Frequency Wireless Technology: · The leva-02 probe includes a microcontroller with a 915 MHz band ISM radio.
  • Page 19: Replacing Batteries

    The batteries should be changed when indicated by the leva PDHS on the Renovia App. To purchase replacement batteries, please contact Renovia at (833) · 450-2914. Replacing the Probe Battery: The probe battery is located at the base of the probe.
  • Page 20 Step 3. Attach the replacement battery pack by pressing it toward the vaginal insert and rotating it clockwise. Step 1 Step 2 Step 3 Remove Remove Attach battery pack sticker replacement battery pack...
  • Page 21: Replacing The Storage Case Battery

    Replacing the Storage Case Battery: The storage case battery is located at the base of the tray component of the storage case. Step 1. Open the case by pressing the ejection button on the side the device. Step 2. Detach the battery from the storage case by rotating the base of the battery counterclockwise.
  • Page 22: Fcc Compliance

    Guidance and manufacturer’s declaration – electromagnetic emissions The leva PDHS is intended for use in the electromagnetic environment specified below. The customer or the user of the leva should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment –...
  • Page 23 RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the leva PDHS is used exceeds the applicable RF compliance level above, the leva PDHS should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the leva PDHS.
  • Page 24: Electromagnetic Interference

    Guidance and manufacturer’s declaration – electromagnetic immunity The leva PDHS is intended for use in the electromagnetic environment specified below. The customer or the user of the leva PDHS should assure that it is used in such an environment. IMMUNITY...
  • Page 25 PDHS should be observed to verify normal operation in the configuration in which it will be used. The leva PDHS should not be used closer than 12 inches to any portable RF communications equipment, including peripherals, such as antenna cables and external antenna’s otherwise degradation of the...
  • Page 26: Symbols

    Manufacturer Follow Operating Instructions Type BF Applied Part, Internally Powered Keep Dry The leva-02 device and storage case are protected from dust. They are also protected against splashing water IP54 from all directions, but they should not be submerged in water.
  • Page 27: Troubleshooting

    Troubleshooting What do I do if my leva will not connect to my mobile device? If your leva PDHS will not connect to your mobile device, make sure the battery pack on both the probe and the case are properly connected. If it still does not connect, make sure Bluetooth is enabled in your mobile device’s settings.
  • Page 28: Faqs

    Sensor Error "Probe Sensor Error: Please close your app and wait a few minutes, then reopen the app and try to proceed with your exercises with leva. Contact support at (833) 450-2914 if this issue persists." FAQs Please see the Frequently Asked Questions section of the Renovia App.
  • Page 29 ©2019 Renovia Inc. All Rights Reserved.