Industrial Dynamics Filtec FT-50 Installation And Setup Manual

Ultraviolet label detector

Advertisement

Quick Links

Ultraviolet Label Detector
Installation and Setup Guide for
Models FT-50 and FT-70
2326-1292

Advertisement

Table of Contents
loading

Summary of Contents for Industrial Dynamics Filtec FT-50

  • Page 1 Ultraviolet Label Detector Installation and Setup Guide for Models FT-50 and FT-70 2326-1292...
  • Page 2 Ultraviolet Label Detector Installation and Setup Guide for Models FT-50 and FT-70 Document 2326-1292...
  • Page 3: Contact Information

    No part of this publication may be reproduced or used in any form or by any means (graphic, electronic, or mechanical including photocopying, recording, taping, or information storage and retrieval system) without written permission of Industrial Dynamics Company, Ltd. ...
  • Page 4 The Ultraviolet Label Detector inspects full-wrap body or neck labels on unoriented containers, or front/back, front or back labels oriented containers. The UV Label Detector photoelectric sensor which is designed to detect the presence of luminescent/fluorescent chemicals and materials, which are invisible except under (see ultraviolet light Figure 1).
  • Page 5 The functions are accessed through the Control Panel. NOTE: feature of the system allows selected displayed messages to be customized for particular application when the system is configured at Industrial Dynamics. For example, ‘LABEL - ’ functions and associated messages TYPE (STATUS, etc.) may be changed to display as MISSING...
  • Page 6: Installation Requirements And Instructions

    The Detector and its Mounting Pole are shipped with minimal assembly required. The only electrical wiring required is connection to the FT-50/70. Refer Drawing Number 25058 and the system Installation Drawing for your system for instructions installing the Ultraviolet Label Detector. 2326-1292 Industrial Dynamics Company, Ltd.
  • Page 7 After the power is on, perform the following calibration steps. Remove the washdown cover and set aside. Before attempting to calibrate the sensor, make sure the lens on the front of the sensor clean and unobstructed. 2326-1292 Industrial Dynamics Company, Ltd.
  • Page 8 Place a production bottle on the conveyor at the station centerline and in the approximate position of a bottle delivered by the bottle positioning guide rail. Ensure that the bottle is approximately 1.6 inches from the lens of the sensor and that the bottle has the proper label to be inspected.
  • Page 9: Software Setup

    Type A has not been assigned another label sensor) or the text assigned your application; LE. MISSING FRONT UP/DOWN or BACK LABEL. Press the arrow keys until the type. shows bottom line ON. This activates this label 2326-1292 Industrial Dynamics Company, Ltd.
  • Page 10 Display shows ADJUST DIST 'STATION n the Text assigned to the sensor. The bottom line will show EXECUTE. Press either the or DOWN arrow key. The information messages and prompt message then displayed: 2326-1292 Industrial Dynamics Company, Ltd.
  • Page 11 UP arrow on the display must be used. When the distance value is incremented or decremented using UP/DOWN arrow keys, the bottom line of the display will change to show STATION n DIST nnn MM where current incremented/decremented value. Example displays: 2326-1292 Industrial Dynamics Company, Ltd.
  • Page 12: Maintenance

    MAINTENANCE using lens a soft tissue or Clean the sensor lens daily cloth. DO NOT USE PAPER TOWELS. Follow the general maintenance procedures outlined in the FT-50/70 manual. 2326-1292 Industrial Dynamics Company, Ltd.
  • Page 13: Troubleshooting

    TROUBLESHOOTING The following Diagnostic Error Numbers are used with Label Inspection. 2326-1292 Industrial Dynamics Company, Ltd.
  • Page 14: Repair And Replacement

    REPAIR AND REPLACEMENT Sensor unit is mounted The sensor on the Ultraviolet Label detector bracket and held in position by metric bolts accessible from Drawing number 25058. Turn off the side of the sensor. Refer the power on the FT-50/70. Remove the washdown cover, unscrew the cable from the back of the sensor, unscrew the two bolts and remove the sensor.
  • Page 15 Replace the threaded plug and tighten securely. Replace the washdown cover and reapply power the FT-50/70. Be careful not to change the alignment of the sensor and the bracket. Lamp Figure 3. Ultraviolet Replacement 2326-1292 Industrial Dynamics Company, Ltd.