For technical support, contact: 011 202 5884 or 083 235 4916.
Features:
-
15 non-user renamable inputs (input names must be specified on order). Alternative methods can be
discussed with supplier
-
All inputs reports to 10 user and 1 technician user
-
Inputs can be single or dual state trip e.g. between 15 and 30 different SMS can be sent.
Quick Start Steps
1. Preparing SIM-card - Buy an MTN, Vodacom or Cell C starter pack (prepaid or contract) and RICA it
(you need your id and proof of address for this). Ensure that you can send an SMS out from the SIM-card,
before you put it in the SIM-card slot of the SMS Alert. Making a call to the SMS Alert only is not sufficient
to test the SIM-card. PIN-code request must be deactivated before you insert the SIM-card into the SMS
Alert.
2. Airtime - Ensure that the SIM-card has sufficient credit. Load airtime if necessary.
3. Insert the SIM-card into the SIM-card slot. Apply 12VDC.
4.
The green LED will flash once when an SMS is sent.
5. SMS 1234 b from your cellphone to the SMS Alert. Note the yellow LED will light up when B is active.
This step tells the SMS Alert where to send SMSe when inputs are tripped. There must be a space
between 1234 and b. If you SMS 1234 b again, you will cancel user B. If you SMS 1234 b again, you
will reload user B. (In other words you will toggle it on & off).
Page 1 of 6