Francis Fernandez
May 8, 2025
Hi, I have problems the alarm is over current and compressor is working about 10sec went i replace sspm board the compressor is not working event 10sec. Can you help me, thanks
1 comments:
Mr. Anderson
May 19, 2025
An overcurrent alarm and compressor failure in a FRIGOMAR CU50VFD after replacing the SSPM board could be caused by high resistance due to corroded, bent, or worn connectors. This leads to overheating, which increases power drop and can trigger overcurrent conditions. Additionally, if the flow switch is not functioning properly and the compressor runs without adequate water flow, it can also cause compressor failure.
This answer is automatically generated
Summary of Contents for FRIGOMAR CU50VFD
Page 1
Via Vittorio Veneto, 112 – Loc. Rivarola 16042 CARASCO (GE) Italia Phone: +39 (0) 185 384888 Fax: +39 (0) 185 384788 Web site: www.frigomar.com eMail: frigomar@frigomar.com USER INSTRUCTION Air Conditioning System Air Conditioning Modular Unit CU50VFD – CU70VFD INVERTER DC chiller-heat pump...
6.3 WARRANTY CONDITIONS : ............................21 7.0 DISPOSAL AND GAS RECOVERY ..........................23 7.1 DISPOSAL OF THE EQUIPEMENT AND PARTS : ......................23 7.2 REFRIGERANT FLUORINATED GAS RECOVERY : ......................23 FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 2 of 24...
Set unit upright and allow to stand 24h on rest. Attempt to start the unit after 24h. If the unit does not start or makes excessive noise, return it to the freight carrier. FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 3 of 24...
WARNING! All electrical work can be performed only by qualified personnel, in conformity with low and regulations of the country where the system is being mounted. The electrical connections must be done following the wiring diagrams, supplied with the unit. FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 4 of 24...
These holes are arranged according to the template shown below and they are accessible from the unit side if you use a wrench or from above (after removing the upper aesthetic cover) if you use a screwdriver (long type). FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 5 of 24...
Fixing holes side accessibility Fixing holes accessibility from above 3.2 WIRING DIAGRAMS To enable Terminal board Warning! Never remove PCB cover, adversely warranty coverage will decline FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 6 of 24...
Serial number Chiller 3.3 TERMINAL BLOCK CONNECTION Power supply 220V/1ph/50-60Hz Max. input power Circuit pump fuse Sea water pump fuse CU50VFD 2.2 kW CU70VFD 3.8 kW FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 7 of 24...
Recommended water pipe sizes (circulation and seawater): FLOW RATE m3/h PUMP INLET PIPE PUMP DISCHARGE PIPE 0.9 – 1.5 3/4” 5/8” 1.5 – 2.5 1” 3/4” 2.5 – 3.4 1” 1” FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 8 of 24...
Page 9
Pump unit Ø mm Ø mm CU50VFD CU70VFD Chiller / Heat Fresh water flow Pressure drop Sea water flow Pressure drop (m3/h) Fresh water (kPa) (m3/h) Sea water (kPa) CU50VFD CU70VFD FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 9 of 24...
1. Check at least once a year, after shutting off the main breaker, the state of all the electrical connections and circuit breakers of the air conditioning system, cleaning and repairing as necessary. These devices are exposed to salty air and suffer over time from corrosion and FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 10 of 24...
MAIN DSP, as shown in the following wiring diagrams. Seawater and circulation water pumps are also managed through the control card. Operation control and system configuration can be achieved from a display panel as shown in the following diagrams. FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 11 of 24...
Page 12
FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 12 of 24...
SEA (seawater pump) lightened if seawater pump ON; FANCOIL (fresh water pump) lightened if circulation pump ON; Alarm active if alarm symbol is lightened; Date and time. FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 13 of 24...
ON/OFF the units will be switched off and if we press again ON/OFF the unit restarts maintaining the previous selected mode (heating/cooling and ECO activate /disabled). 4.3 PAGE MENU SETTINGS 1/2 : FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 14 of 24...
EEV steps ( range 0-480 steps); Frequency set (range 0-100 Hz); Frequency real (range 0-100Hz ); Gas superheating (calculation as a difference between Suction Gas Temperature and Evaporation Gas Temperature). FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 15 of 24...
Tge Evaporation gas temperature (from pressure transducer R410A, or other future refrigerants) 0-20 bar . Tgc Condensing gas temperature (from pressure transducer, if available, for R410A or other future refrigerants) 0-50 bar FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 16 of 24...
Txx (description): probe unreliable; to be included also the pressure transducers failure (for the pressure transducer on the compressor discharge the alarm is disabled if INP25=0, since such transducer is not used, to save unnecessary cost) FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 17 of 24...
Once finish the input, and press OK, the number will be changed. This can be suitable for date, hour setting and password input. 4.4.1 Clock set Date: hour: 0-24, min: **; date: year****/month**/day** FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 18 of 24...
This can clog strainers, water pumps and heat exchangers in a little while, causing shut-down faults and sometimes equipment damage. In such particular conditions, please seek the advice of a local Frigomar service representative. Any possible modification to the overall system (chiller, pumps, strainers, etc) that could overtake the problem must be approved by Frigomar, otherwise warranty coverage will decline.
For proof of the date that the Frigomar product was put in service, Frigomar will require a copy of the bill of sale from the Frigomar product installer or a copy of the bill of sale showing the date of delivery from the new boat dealer to the original owner.
Frigomar Customer Service all this information related to the faulty parts. Normally the preferred way is to e-mail the data plate photos. Frigomar may also require a copy of the bill of sale from the Frigomar product installer or a copy of the bill of sale showing the date of delivery from the new boat dealer to the original owner, as a proof of the date that the Frigomar product was put in service.
Page 22
To keep clean the fan coil water circuit. To pay the charges incurred when any of the above has not been done. To pay for repair or replacement of any material or part other than those within the Frigomar unit.
Pay attention to safety when draining the oil from the system. NOTE: _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ FRIGOMAR ENG - CU50VFD-CU70VFD 20190108.doc81218 Page 23 of 24...
Page 24
Their main features. The technical data presented in this document are not binding. FRIGOMAR S.r.l. we reserve the right to make any changes at any time deemed necessary to the improvement of the product.
Need help?
Do you have a question about the CU50VFD and is the answer not in the manual?
Questions and answers
Hi, I have problems the alarm is over current and compressor is working about 10sec went i replace sspm board the compressor is not working event 10sec. Can you help me, thanks
An overcurrent alarm and compressor failure in a FRIGOMAR CU50VFD after replacing the SSPM board could be caused by high resistance due to corroded, bent, or worn connectors. This leads to overheating, which increases power drop and can trigger overcurrent conditions. Additionally, if the flow switch is not functioning properly and the compressor runs without adequate water flow, it can also cause compressor failure.
This answer is automatically generated