Hussmann impact Excel C2X-LGE Technical Data Sheet page 10

Hussmann c2x-lge: data sheet
Hide thumbs Also See for impact Excel C2X-LGE:
Table of Contents

Advertisement

C2X-LGE
Impact Excel
Dairy/Delicatessen
Precut & Packaged Produce
The ballast for the canopy and shelf lamps is
located behind the canopy on the left-hand end
(when facing case) of the merchandiser.
To access the ballast:
1. Remove screws at bottom edge of canopy and
rear of light channel.
2. Lower light channel which will pivot on
hinge.
3. Service or replace ballasts as required.
4. Reassemble items as they were originally
installed.
NOTE: Rail lamp ballast is located in the
electrical raceway.
CANOPY ANTI-SWEAT HEATER
The canopy anti-sweat heater location is shown
below. Connections are in the electrical wireway.
10 of 10
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Foil-covered
Anti-sweat
Canopy
Heater
Light Channel
Remove Screws
Light Channel
Hinge
Ballast
Light
Channel
Electrical Wireway
Anti-Sweat Heater Wires
with Purple Markers