Chemical safety ......................3 Intended use ....................... 4 Reasonably foreseeable misuse ................. 4 Unpacking and transport ..................... 5 Installation of the BioSpot BT600 ................. 5 List of parts ........................5 Description of the BioSpot BT600 ................. 6 BioSpot BT600 workstation ..................6 Connectors at the control electronics located at the z-axisFehler! Textmarke nicht definiert.
Electrical Safety Warning! High voltage hazard Do not open the BioSpot BT600! The device contains circuits which carry power supply voltage. Opening is only allowed to skilled personnel while the power plug is disconnected. Inadmissible operations will nullify the warranty!
Prevent the entrance of any foreign object as liquids or screws into the BioSpot BT600 device. It is prohibited to store or place any object on the platen of the BioSpot BT600 which is not in the purpose of use. Keep your hands away from all moving elements during operation.
Machinery Directive. Furthermore, the customer is in this case responsible for certificating the final device in purpose of own use or distribution. Other use as listed is not allowed and will lead to damage of the BioSpot BT600. The whole product may not be changed or reconstructed.
CONSIDER: some parts might extend the borders of the system during operation! List of parts Please make sure that the following items are part of your BioSpot BT600 system. If any items are missing please contact BioFluidix immediately. CONSIDER: Print heads, dispensers or other components must be ordered separately and are not...
Manual - BioSpot BT600 workstation Description of the BioSpot BT600 The BioSpot BT600 is a laboratory robot enabling the positioning of print heads or dispensers authorized by BioFluidix GmbH. According to the intended configuration, the BioSpot BT600 can be applied as pipetting or dispensing unit for non-contact dosage applications of liquids.
Page 8
LED blue indication for axes movement (illuminates while any axis x/y/z is moving) power toggle switch (back side) enables the power supply of the BioSpot BT600. Using this switch supplies all components with power, including PC and dosing electronics. emergency switch Pressing the emergency switch disconnects all internal components from the power supply, except the internal PC and the power switch on the back side.
Print heads and dispensers (can be ordered separately) The BioSpot BT600 is able to operate different printheads or dosing units authorized by BioFluidix GmbH. Print heads and dosing units need to be ordered separately. Accessories (can be ordered separately) Accessories can feature essential methods to improve or support the development of the desired dosing process or be applied to implement process control.
Page 10
Manual - BioSpot BT600 workstation Optical droplet sensor • o online process control of dosing process by counting ejected droplets o semi quantitative process control by correlation of generated signals • Pressure controlled reservoir guarantees constant pressure at the dosing nozzle...
BioFluidiX Control Software BETA Manual V1.0” additional “ carefully! 1. Connect a mouse and keyboard to the BioSpot BT600 backside USB connectors. Connect a screen to the backside DVI connector. 2. Connect the BioSpot BT600 to a standard power supply socket (90 - 240V).
Serto aspiration connectors. Serto aspiration connector Switching off 1. Close the BioFluidix Software 2. Shut down the PC 3. Switch off the BioSpot BT600 by switching the backside toggle power switch to “0” (off) page 11 of 15...
Appendix Basic settings The basic settings for the BioSpot BT600 workstation are stored in the registry editor of the Windows 7 OS installation. In case of damage or dysfunction of the device you can request for the original set of registry entry by BioFluidix.
32 kg (depending on the individual configuration) Environmental operation conditions: Temperature: 10°C - 30°C Humidity: 10 - 80 % (non-condensing conditions) Dimensions Figure 3: technical drawing of the BioSpot BT600 showing the dimensions and stating the addressable area by one dispenser page 13 of 15...
Maintenance and repair To guarantee impeccable functionality of the BioSpot BT600 workstation we recommend to arrange a service of the device by BioFluidix once a year. Necessary maintenance needs to be accomplished by BioFluidix members or authorized personnel only. Bevor sending the BioSpot BT600 workstation to service, check for contaminations of hazardous or environmental- and health threatened substances that may have been formed during use and remove them if required.