Liquid Ring Vacuum Pump Instruction Guide ( Model : Mega Power I ) Caution: Use this Liquid ring vacuum pump Only for its intended use as described in this manual. Improper use or failure to do so could result in personal injury or property damage.
B. This manual has been complied not only for the care and maintenance of the Dmega suction system now in your possession, but as a helpful Reference and guide to prevent many problems which can be occurred...
Mega Power - Liquid Ring Vacuum Pump Included Accessories Suction unit 2. 19 Ø Water Inlet tuning (1 m) & 19 Ø Drain outlet tubing (1.5 m) Product manual 2) Important Safeguards Note: Read all instructions carefully before use. The following basic precautions are needed when using the product. Caution: Failure to read and observe all precautions could result in personal injury or equipment damage.
Page 5
2. Do not immerse the unit in water. It may damage the unit. 3. Disconnect the unit from the electrical outlet before cleaning 3) Device Specifications: Mega Power I / 230V Mega Power I / 115V Item Model name MP1-115...
Page 6
Mega Power - Liquid Ring Vacuum Pump 4) Installation Instruction A. Plumbing drawing...
Installation step Check the shipping carton for damage. This could detect damage to the unit which might otherwise be overlooked. Take out the vacuum pump from its shipping carton. Inspect the unit for damage. Place the vacuum pump at installation place. Connect Inlet & Outlet hose. to the vacuum pump.
Page 8
Mega Power - Liquid Ring Vacuum Pump Every 1 year Maintenance Clean Water Inlet strainer (Y- type) If main tap water condition is not clean, check the water inlet strainer if necessary or every 1 year. The water inlet strainer has small wire mesh inside to remove rust. Use large crescent wrench to remove nut.
5. Trouble Shooting Trouble Shooting Chart Problem Possible Cause(s) Solution Check all wires for loose If voltage is not present, replace the Motor will or broken connections. transformer or fuse. not Start Check fuse. Check low when voltage o f m ain po w er Turned Test solenoid valve by If water flow does not stop with power...
Page 12
Mega Power - Liquid Ring Vacuum Pump Symptom Possible Cause(s) Solution Clean screen of filter Low or Filter is clogged vacuum Turn pump OFF immediately to Water inlet strainer is prevent internal damage. clogged not allowing Then unclog water inlet s trainer water to go through pump.