Rotomotive Powerdrives ROBUS 12 Operation And Maintenance Manual

Helical in-line gearboxes

Advertisement

Quick Links

ROBUS
helical in-line gearboxes
Operation and maintenance manual ROBUS units
Page 1 OF 13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ROBUS 12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rotomotive Powerdrives ROBUS 12

  • Page 1 ROBUS helical in-line gearboxes Operation and maintenance manual ROBUS units Page 1 OF 13...
  • Page 2: Components List

    COMPONENTS LIST Operation and maintenance manual ROBUS units Page 2 OF 13...
  • Page 3 Operation and maintenance manual ROBUS units Page 3 OF 13...
  • Page 4: Installation

    STORAGE Do not store outdoors, in areas exposed to weather or with excessive humidity. • For storage periods longer than 60 days, all machined and unpainted surfaces such as • flanges, bases, and shafts must be protected with a suitable anti-oxidation product Oil seals must be touched by the oil.
  • Page 5: Routine Checks

    ROUTINE CHECKS Periodically check that the outer surfaces of the ENDURO unit and the cooling air passages • are clean. Verify that the breather plug hole is clean. • Regularly make sure that there are no lubricant leaks. • Using the level plug window, verify periodically the correct quantity of lubricant •...
  • Page 6 LUBRICATION Unless otherwise specified, each ENDURO is supplied long-life synthetic oil (quantity as per position B3). You must replace the oil each 20.000 working hours and anyway every 5 years at least After an eventual oil addition, each ROBUS can be mounted in any mounting position, thus giving big advantages in the stock management and lead time All units are supplied with plugs for loading, discharging and checking the level of the oil.
  • Page 7 V5 / V1 Operation and maintenance manual ROBUS units Page 7 OF 13...
  • Page 8 Mounting positions breather plug level plug filler plug Operation and maintenance manual ROBUS units Page 8 OF 13...
  • Page 9 OIL SEALS REPLACEMENT When a shaft seal doesn’t work properly, it must be replaced rapidly, in order to avoid that the oil leakage goes further on, and that the damage extends to some other components. When fitting a new seal, the following precautions are required: take particular care in handling, and make sure that the seal is in •...
  • Page 10 Max FR1 (at 0Kg FA1) - ROBUS-MF Operation and maintenance manual ROBUS units Page 10 OF 13...
  • Page 11 Max FR2 (at 0Kg FA2) Operation and maintenance manual ROBUS units Page 11 OF 13...
  • Page 12 CAUSE PROBLEM POSSIBLE CAUSES REMEDY (1) REMEDY (2) the motor doesn't start a)problems in the power check the connections and replace the motor. supply. b)faulty electrical wiring. power supply c) faulty motor. d)wrong size of the motor the current absorption of the a) wrong motor size.
  • Page 13 BEEN CHECKED WITH MAXIMUM CARE. WE HOWEVER DO NOT ASSUME RESPONSIBILITY FOR ANY UNINTENDED ERRORS AND OMMISSIONS. ROTOMOTIVE RESERVES THE RIGHT TO CHANGE THE SPECIFICATIONS OF ITS PRODUCTS AT ANY TIME. Rotomotive Powerdrives India ltd. 223, Napa Talpad, Gana-Borsad Road, Tal : Borsad, Anand Gujarat – 388 560, INDIA.

This manual is also suitable for: