Our integrated AI software built into the Basic model can detect up to 30 independent temperatures in sequence. Including face alarm detection, data comparison, and real time face capture.
TEMPRACAM | BASIC Statement • The contents herein will be updated f rom time to time and dded to the newly revised manual without notice. • This manual may contain technical inaccuracies or printing errors. Safety Cautions: • When installing the device, please be certain it is done only by qualif ied personnel.
TEMPRACAM | BASIC Device Installation Mobile Station Host Installation Take out the host bracket in the accessory, Insert the host bracket into the bracket port on the mobile station through the entire mobile station case until reaching the bottom. Fix the bracket with screws as shown below.
TEMPRACAM | BASIC Device Installation Black Stand Installation Open the bottom supporting seat of tripod supporting the stand and place on the ground, as shown below. Take out the stand in the ancillary, and align the screw holes at the bottom (as shown below) with the ¼”...
Page 11
TEMPRACAM | BASIC Device Installation Black Stand Installation (Part 2) Adjust the height of the expansion links of the tripod, and fasten the locking module, as shown below. Connecting Screw Locking Module 1 Locking Module 2 The middle black body bracket is about 3-5 meters f rom the mobile station, and the black body position is adjusted to the upper right or left corner of the inf rared image.
TEMPRACAM | BASIC Fixing & Positioning Carry out wiring design and installation method as required by the user. The installation should be carried out indoors as shown. Page 12 | Fixing & Positioning...
RAM: 4GB and above Recommended Minimum Resolution: 1920x1080 Display: 22 inch and above - widescreen recommended Installing the Software: To download the software please visit tempracam.com/pages/support Step 1: Click Next. Step 2: Click Install. Step 3: Wait for install to f inish.
TEMPRACAM | BASIC Using the Software At the completion of the installing the software, double click the camera icon on your desktop to launch the application. Provide real-time image preview, with face large image rolling Real-time Preview and temperature measurement value displayed on the left side, and current-day statistics on the right side.
TEMPRACAM | BASIC Real-time Preview Conf iguration Wizard before Real-time Preview Add device correctly in “Device Manager”, “Start up Device” after selecting device to start preview. 2. Set the black body position in “Temperature Measurement Conf iguration” > “Black Body Conf iguration”.
TEMPRACAM | BASIC Interface Overview Real Time Monitoring Provide inf rared and visible light, real-time video monitoring, and display the face detection f rame including the highest temperature stats. Supports multiple people for simultaneous scanning. Warning Capture When the detection reads the preset temperature alert value, the system will capture the visible and inf rared images automatically and trigger the sound alarm.
Page 17
TEMPRACAM | BASIC Interface Overview Manual Video Recording Click the manual video recording button to begin. Inf rared and visible light can be recorded simultaneously. To stop recording, click the manual record button again. Statistical Chart Generate various bar charts automatically according to the daily / weekly real-time temperature measurement data.
TEMPRACAM | BASIC Device Management If there is no device for the f irst installation by default, which is conf igured by “Device Management” > Add Device > Device Information Conf iguration > Add Device How to Add a Device •...
Page 19
TEMPRACAM | BASIC Device Management How to Remove a Device Select the device in the device list column and select “Delete Device”. As shown below: Start Up Device When adding multiple devices, select the device in the device list column. To switch monitoring screen, select start up device and display the preview screen in “real-time preview”...
TEMPRACAM | BASIC Device Settings Temperature Measuring Conf iguration Infrared color mode selection, surveillance video OSD information, time synchronization and device calibration functions. Visibile light Image Settings video brightness, contrast, chroma, saturation and other video settings. For interference with temperature exceeding high temp preset, Blind Settings set blind zone to prevent false alarm.
TEMPRACAM | BASIC Image Settings Open up the image settings interface via “Temperature Measuring Conf iguration” > “Image Setting. Inf rared Image Settings Inf rared Image Settings Include: Inf rared video color multi-mode selection, OSD information display, and time synchronization settings.
Page 22
TEMPRACAM | BASIC Image Settings OSD Information Setting: Provide OSD information (such as time, device name, and custom contact overlays. Location settings can also be changed on inf rared video. Time Synchronization: Adjust the time of the f ront-end device to current time displayed on desktop.
TEMPRACAM | BASIC Image Settings Blind Settings (Shield Area) Click the “Shield Area” button on the left side panel to access. In case of any object with temperature exceeding the high value set detected in the image, this function may be adapted. There will be a temperature measurement and alarm in the effected zone after screening.
TEMPRACAM | BASIC Image Settings Temperature Compensation Click the “Compensation” button on the left side panel to access. Enter Ambient Temperature Enter Manual Value Provides 3 temperature correction modes: Automatic compensation, manual compensation, and shell temperature compensation according to ambient temperature.
TEMPRACAM | BASIC Image Settings Double Light Calibration Click the “Calibration” button on the left side panel to access. As the optical f ield angles of inf rared and visible light are different, if the double light correction is not carried out, the object image positions displayed in the inf rared and visible light real-time image previews will differ.
TEMPRACAM | BASIC Image Settings Black Body Conf iguration Click the “Black Body” button on the left side panel to access. Using the black body as the reference source of temperature measuring, the system will automatically carry out real-time temperature measurement correction, to ensure the accuracy of temperature measurement.
TEMPRACAM | BASIC Image Settings Alarm Conf iguration Click the “Alarm” button on the left side panel to access. The alarm conf iguration consists of two parts, “parameter conf iguration” and “face detection dimension”, which can be switched via the “alarm” tab.
Page 29
TEMPRACAM | BASIC Image Settings Alarm Parameter Conf iguration Standard Alarm Mode: Allows for zone temperature detection, which will sound alarm in case of being over temperature without distinguishable people or objects. Face Alarm Mode: Only measures the temperatures of the recognized faces and will sound alarm in case of over temperature.
TEMPRACAM | BASIC Image Settings Local System Settings Click the “System” button on the left side panel to access. Path Setting: Provide optional saving paths for video and image f ile saving. File Saving Period: 30 days by default. Language Options: Provides options to switch language formats to Chinese, Japanese, Korean, English, Russian, Turkish, and others.
TEMPRACAM | BASIC Record Query Provides searching and playback function of image and video records. Select the time period and f ile type (picture/video) to be searched as required and click “Query” to display the history of the time period in the upper list column. Switch page number by turning the page on the bottom right.
Page 32
TEMPRACAM | BASIC Record Query Selection Face Detection Corresponding Image Query Conditions Execute Search Turn Page The “name” column in the record information searched will be displayed as “specif ic name” when entered into the face database. It will then be recognized as “no name” when not entered into the face database or recognized.
Page 33
TEMPRACAM | BASIC Statistical Graph Automatically generate real-time statistical bar charts according to the temperature measurement data of the day, and the week for analysis. Current Day Stats Last Week Temp Stats Current Day Flow Rates Page 33 | Statistical Graph...
TEMPRACAM | BASIC Database Management Face database management includes two modules, face modeling and data maintenance. Face Database Modeling Click the “Face Database Modeling” tab in the “Face Database Management” tab. Face database modeling provides two input modes, manual input and batch input.
Page 35
TEMPRACAM | BASIC Database Management 4. The personnel information is displayed in the information column for view and conf iguration. 5. At the completion of personnel information entry, click “update” to import into the local face database. Requirements on face information acquisition: 1.
Page 36
TEMPRACAM | BASIC Database Management Local Face Database Batch Entry Steps 1. Enter into the personnel information in the format below in the local Excel f iles as shown in the f igure below, and save as .csv format. Manually create a photo folder, to save all personnel photos in the format of “name.jpg”.
Page 37
TEMPRACAM | BASIC Database Management Data Maintenance Click the “Database Management” button on the top side panel to access. At the completion of entry on all personnel information, click “inquire Personnel” to conf irm personnel information entered, and carry out “upload modeling data” operation. Upon completion, upload all the personnel information to the host device for saving.
TEMPRACAM | BASIC Cautions for Use 1. After the start-up of temperature measuring device, there is a self-inspection duration of about 30 seconds. During this period, the system software cannot be connected to the device end. 2. The system software is generally installed in the factory. Click the operation program for utilization on site.
Need help?
Do you have a question about the Basic and is the answer not in the manual?
Questions and answers