Oasis Aquatics V Series Installation And Operation Manual

Oasis Aquatics V Series Installation And Operation Manual

Variable 3 speed pool & spa pump

Advertisement

INSTALLATION AND OPERATION MANUAL
V SERIES Variable 3 Speed Pool & Spa Pump
Head Office
62 Parkhurst Drive
Knoxfield VIC 3180
T: 03 9887 2131
V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
New South Wales
Unit 1, 20-22 Foundry Road
Seven Hills NSW 2147
T: 02 9838 0000
V SERIES
V310 | V390 | V480
Queensland
Unit 4, 8 Reichert Drive
Molendinar QLD 4214
T: 07 5679 6821
info@oasisaquatics.com.au
oasisaquatics.com.au
info@oasisaquatics.com.au
oasisaquatics.com.au
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Oasis Aquatics V Series

  • Page 1 Seven Hills NSW 2147 Molendinar QLD 4214 oasisaquatics.com.au T: 03 9887 2131 T: 02 9838 0000 T: 07 5679 6821 V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL oasisaquatics.com.au...
  • Page 2 • Do not block water entry into filtration system with any part of your body as the suction can trap hair or body parts, causing severe injury or death. Do not block suction. Turn off pump immediately if someone becomes trapped. V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL...
  • Page 3 • Ensure that an electrical isolation switch is located with easy access so that the pump can be switched off in an emergency. V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL...
  • Page 4: Features And Benefits

    • Constructed of strong corrosion and U.V. resistant materials for long life. • A.B.S. quick connect couplings makes installation simple. V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL oasisaquatics.com.au...
  • Page 5: Installation Instructions

    If the supply cord of this product is damaged the dealer or manufacturer must replace it, with genuine OASIS pool and spa pump spares. • Water temperature is not to exceed 45 degrees V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL oasisaquatics.com.au...
  • Page 6: Pipe Connection

    V310. If not a suitable chlorinator may be required. • Oasis’s CX chlorinator completely disconnects power to the pump when the pump is in off mode. V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL oasisaquatics.com.au...
  • Page 7: Operation

    (ie. Check valve, air leaks, faulty seal/s, crack lid. V SERIES VARIABLE SPEED CONTROL V Series V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL oasisaquatics.com.au...
  • Page 8 Medium @ 2400 High @ 2850 V480 @ 8 Star Low @ 1320 Medium @ 2400 High @ 2850 ADJUSTABLE SPEED MODE V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL oasisaquatics.com.au...
  • Page 9 PLEASE NOTE • The V SERIES PUMP will always run at “high” speed for 5 minutes upon start up or a filter cycle. This assists with priming of the pump and pipe work. • After the initial 5 minutes the PUMP will revert back to the previous selected speed it was set at before it was turned off.
  • Page 10 PLEASE NOTE • The V SERIES V390 will always run at “high” speed for 5 minutes upon start up or a filter cycle. This assists with priming of the pump and pipe work. • After the initial 5 minutes the V390 PRO will revert back to the previous selected speed it was set at before it was turned off.
  • Page 11: Water Quality

    • Disconnect cleaner and remove from pool once it is cleaned. Change setting back (usually “eco”) to your daily filtration requirements. V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL...
  • Page 12: Troubleshooting

    4. Remove the discharge & suction barrel unions taking care not to lose the o-rings. 5. Move the pipe work with the barrel unions attached until the pump can be moved clear. V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL oasisaquatics.com.au...
  • Page 13: Fault Codes

    • The pump is not intended for use by young children or infirm persons without supervision. Ensure that young children are supervised at all times to ensure that they do not play with the pump. V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL...
  • Page 14 Operating Instructions and all applicable statutory requirements. Product specifications may change without notice. • Warranties vary in different States and/or Territories. COMMENTS / NOTES V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP info@oasisaquatics.com.au INSTALLATION AND OPERATION MANUAL oasisaquatics.com.au...
  • Page 15: Limited Warranty

    LIMITED WARRANTY Your Oasis V SERIES V310 / V390 PRO pool and spa pump is covered by a limited three-year warranty. Please refer below for details as follows: • 3 year limited warranty against defects in workmanship and materials excluding obvious neglect, misuse, improper installation or improper maintenance from date of purchase.