  • Page 1 StorMonitor Installation and commissioning manual StorMonitor - Installation & commisionning - V2009.01 GB.doc – V2009.01...
  • Page 2: Table Of Contents

    II-1 Installing the StorMonitor main unit..…………………....……………………………….4 II-2 Installing the antenna ………………………………………..……………….……………4 II-3 Finding a position to site the antenna …………………………......……….……..5 III – LIMITATIONS TO USE ……………………………………………...…………………………………..5 IV – CONNECTION PRINCIPLES ………………………………………....……………………………..6 StorMonitor - Installation & commisionning - V2009.01 GB.doc – V2009.01...
  • Page 3: I - General Remarks

    A 230Vac/12Vdc power supply connected to the box via a jack plug. The StorMonitor system is designed to be installed on a desk, or equivalent, inside a building. 1 StorMonitor main unit : H:40 / L:214 / D: 133 (mm)
  • Page 4: Installation And Commissioning

    Connect the power supply unit to the mains, then connect its male Jack to the female socket 6 on the back of the StorMonitor main unit : check that the green "POWER" LED 2c on the processing unit is on.
  • Page 5: Ii-3 Finding A Position To Site The Antenna

    Note: 1- Lightning activity in the sky may not be detected by the StorMonitor; in fact, everything depends on the distance separating it from the antenna. As an indication, lightning can be seen with the naked eye up to a distance of 90 km, therefore well beyond the antenna's sensing range.
  • Page 6: Connection Principles

    Timeout of the "Storm in progress" alarm: 10 minutes, retriggerable by lightning occurring during this timeout. Alarm contact: NO, no voltage, rating 24Vdc/1A on resistive load. For further details concerning use, please refer to appendices 1, 2 and 3. END OF DOCUMENT StorMonitor - Installation & commisionning - V2009.01 GB.doc – V2009.01...
  • Page 7 Appendix 1 - StorMonitor main unit description Front panel of the processing unit : LED visualization 0 0 0 0 1 2 Dangerous thunderstorms counter Bargraph indicating Reset storm memory the level of storm activity LED number Function Lightning strike detection...
  • Page 8 Appendix 2 - Adapting the antenna's cable length 1 - Antenna with its cable ended by a 9-pin SubD male connector : Antenna SubD connector Cable gland Cable length = 25 meters 2 - Insertion of transition connector blocks to increase or decrease the cable's length : J2 SubD connector (customer's interface)
  • Page 9 Appendix 3 - Fastening the antenna 1 - Fixing on a steel tube : Galvanized steel tube, ext. diam.: 30mm U-shapped steel fixing Metal plate for strenghtening Cable gland for antenna's cable Fastening - top view Be sure that the antenna is always fixed in one of both shown positions. Fastening - cross-section Mast fixed to the building Antenna...