FAILURE TO FOLLOW THE MANUAL MAY RESULT IN SERIOUS INJURY/DAMAGE.
DISCLAIMER OF LIABILITY
This manual describes the installation, operation and maintenance of the solar photovoltaic module.
The installation, handling and use of Sova Solar crystalline modules are beyond company control. Sova Solar
does not assume any responsibility for loss, damage, injury or expense resulting from the improper
installation, handling, use or maintenance.
Sova Solar assumes no responsibility for any infringement of patents or other rights of third parties that
may result from use of the module. No license is granted by implication or under any patent or patent rights.
Specifications included in this manual are subject to change without prior notice
SAFETY
 Follow the general and national safety and accident prevention regulations.
 Instructions relating to the functional safety of the system are in bold type.
 Do not connect any defective or damaged equipment (including measurement equipment) to PV
modules.
 Follow the charging instructions of the battery manufacturer.
 Check the charging process regularly as described by the charger manufacturer.
 Never alter or remove the factory plates and identification labels.
 Keep children away from PV systems.
 Do not use water to extinguish fires of an electrical origin.
 Do not walk on the modules
The warnings, precautions and instruction discussed in this manual cannot cover all possible
conditions and situations that may occur. The module should be used with common sense and
caution by the end user.
INSTALLATION WARNING
DANGER OF EXPLOSION FROM SPARKING! DANGER OF ELECTRIC SHOCK!
Solar modules generate electricity under incident light. The open circuit high voltage is present, even when
the incident light levels are low. So it is recommended that the connection to the charge controller, load and
battery may only be connected by trained personnel and i accordance with the applicable regulations.
www.sovasolar.com
READ THIS MANUAL BEFORE USING SOVA SOLAR PRODUCTS.
.
"Preserve the manual for long use"
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SS35572MC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SOVA SOLAR SS35572MC

  • Page 1 Sova Solar assumes no responsibility for any infringement of patents or other rights of third parties that may result from use of the module. No license is granted by implication or under any patent or patent rights.
  • Page 2 INSTALLATION & SERVICE INSTRUCTIONS MANUAL FOR SOLAR PV MODULE FOLLOW THE INSTALLATION AND OPERATING INSTRUCTIONS FOR PV MODULE AND ALSO FOR ALL COMPONENTS OF THE PV SYSTEM.  Protect the solar modules from incident light during installation, e.g. cover them. ...
  • Page 3: Climate Condition

     Do not place modules directly on top of each other. CLIMATE CONDITION  Install the SOVA SOLAR Photovoltaic modules in the following conditions: Operating temperature: - 40°C to +85°C.  Storage temperature: -40°C to +50°C.  Humidity: below 85RH%.
  • Page 4 (Oblong- Vertical(mm) Horizontal(mm) Range(Polycrystalline) (MONO PERC) Dimension(mm) 1961 x 991 x 40 8 x 10 SS29572MC - SS35572MC SS33072MP - SS40072MP 1802 x 991 x 40 8 x 10 SS28066MC - SS34066MC SS30566MP - SS36566MP 1646 x 991 x 40...
  • Page 5: Series / Parallel Connections

    INSTALLATION & SERVICE INSTRUCTIONS MANUAL FOR SOLAR PV MODULE SERIES / PARALLEL CONNECTIONS Modules can be wired in series to increase voltage. Connect wires from positive terminal of one module to the negative terminal of the next module. All modules connected in series should be of the same model number and/or type.
  • Page 6: Roof Mounting

     For roof application, the modules should be mounted over a fire resistant covering rated for the application  Sova Solar PV Modules have a Class C fire resistance rating in accordance with IEC 61730 certification. The fire rating of this module is valid only when mounted in the manner specified in the Mechanical mounting instructions.
  • Page 7 INSTALLATION & SERVICE INSTRUCTIONS MANUAL FOR SOLAR PV MODULE FUSING  When fuses are fitted they should be rated for the maximum DC voltage and connected in each, non- grounded pole of the array (i.e. if the system is not grounded then fuses should be connected in both the positive and negative poles).
  • Page 8: Technical Data Sheet

    Electrical Ratings (Polycrystalline Module) Fuse Module Model Name Voltage rating (A) weight (Kg) Voc (V) Vm (V) Isc (A) Im (A) Pm (W) Eff (%) 72 Cells SS35572MC 1500 46.77 37.69 9.73 9.42 18.27 21.3 SS35072MC 1500 46.68 37.53 9.62 9.33 18.01...
  • Page 9 INSTALLATION & SERVICE INSTRUCTIONS MANUAL FOR SOLAR PV MODULE 54 cells SS28054MC 1500 35.80 28.67 9.98 9.78 19.03 16.2 SS27554MC 1500 35.53 28.50 9.92 9.66 18.69 16.2 SS27054MC 1500 35.36 28.21 9.85 9.58 18.35 16.2 SS26554MC 1500 35.17 28.09 9.64 9.44 18.01 16.2...