Download Print this page

Advertisement

INSTRUCTION MANUAL
H
L
A
OLTEN
AMIN
IR
SAFE 2000
MAXI SAFE 2000
ID: 807222
Erreur ! Argument de commutateur inconnu.

Advertisement

loading
Need help?

Need help?

Do you have a question about the LaminAir SAFE 2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Heto Holten LaminAir SAFE 2000

  • Page 1 INSTRUCTION MANUAL OLTEN AMIN SAFE 2000 MAXI SAFE 2000 ID: 807222 Erreur ! Argument de commutateur inconnu.
  • Page 2 Page Erreur ! Argument de commutateur inconnu./15INSTRUCTION MANUAL SAFE 2000/MAXI SAFE 2000 Fig. A Control Panel Fig. B LCD Display Erreur ! Argument de commutateur inconnu.
  • Page 3: Table Of Contents

    SAFE 2000/MAXI SAFE 2000 INSTRUCTION MANUALPage Erreur ! Argument de commutateur inconnu./15 Contents Page: 1 Introduction..................3 2 Safety Precautions................3 3 Installation................... 3 4 Working Rules..................3 5 Operation..................... 3 6 Technical Specifications..............3 7 Maintenance ..................3 Enclosures: List of recommended disinfectants Log-book Declaration of conformity...
  • Page 4: Introduction

    Page Erreur ! Argument de commutateur inconnu./15INSTRUCTION MANUAL SAFE 2000/MAXI SAFE 2000 Introduction You are now in possession of a high quality microprocessor controlled class II cabinet, H OLTEN 2000, designed to provide protection of the operator, the surroundings and the work process itself against particle/microbiological contamination.
  • Page 5: Installation

    SAFE 2000/MAXI SAFE 2000 INSTRUCTION MANUALPage Erreur ! Argument de commutateur inconnu./15 The H 2000 class II cabinet will not provide any protection for operator or OLTEN surroundings against harmful gases or vapours. Remove hands from the work chamber prior to activating sliding mode for the front window ! Installation 1.
  • Page 6 Page Erreur ! Argument de commutateur inconnu./15INSTRUCTION MANUAL SAFE 2000/MAXI SAFE 2000 Figure Erreur ! Argument de commutateur inconnu.. 2. The installation site for the unit should be draught-free and should be selected so that frequent passing of persons in front of the work opening is avoided. 3.
  • Page 7: Working Rules

    SAFE 2000/MAXI SAFE 2000 INSTRUCTION MANUALPage Erreur ! Argument de commutateur inconnu./15 Working Rules Rules to follow prior to use... - The cabinets should be used indoors in a normal clinical environment with a temperature between 18 °C and 28 °C, normal humidity and atmospheric pressure. - All the cabinets are designed and produced to be used in clean environments.
  • Page 8: Operation

    Page Erreur ! Argument de commutateur inconnu./15INSTRUCTION MANUAL SAFE 2000/MAXI SAFE 2000 Operation Fig. A: 1. Button ON / OFF for UV light (optional). - The UV light can only be switched on when the chamber light is off and front window brought in lowest position.
  • Page 9 SAFE 2000/MAXI SAFE 2000 INSTRUCTION MANUALPage Erreur ! Argument de commutateur inconnu./15 ØHow to set time and day of the week... Turn the lock-switch to position 1 and..1. Press the [ENTER] button while connecting the cabinet to power 2. Press the [MENU] button once, and the display will flash for setting minutes. 3.
  • Page 10 Page Erreur ! Argument de commutateur inconnu./15INSTRUCTION MANUAL SAFE 2000/MAXI SAFE 2000 3. Press the [ENTER] button to start count down. When the stopwatch has counted down to 00:00 the acoustic alarm sounds. ØAlarm... When the alarm is activated, the acoustics alarm sounds and the display light flashes indicating that the cabinet does not provide full protection for the operator and the product.
  • Page 11 SAFE 2000/MAXI SAFE 2000 INSTRUCTION MANUALPage Erreur ! Argument de commutateur inconnu./15 Erreur ! Argument de commutateur inconnu.
  • Page 12: Technical Specifications

    Page Erreur ! Argument de commutateur inconnu./15INSTRUCTION MANUAL SAFE 2000/MAXI SAFE 2000 Technical Specifications Model 0.9 Model 1.2 Model 1.5 Model 1.8 Safe Maxi Safe Maxi Safe Maxi Safe Maxi Safe Safe Safe Safe Cat. no. 57240000 47240000 57250000 47250000 5726000 47260000 5727000 47270000 External Dimensions...
  • Page 13: Maintenance

    SAFE 2000/MAXI SAFE 2000 INSTRUCTION MANUALPage Erreur ! Argument de commutateur inconnu./15 Maintenance Recommended maintenance: • DAILY: The work area is disinfected. Also lift the table tops and carefully wipe the backside and the trough. • WEEKLY: Wipe the exterior of the unit with a mild household detergent. HOW TO CLEAN THE INSIDE FRONT WINDOW: 1.
  • Page 14 Page Erreur ! Argument de commutateur inconnu./15INSTRUCTION MANUAL SAFE 2000/MAXI SAFE 2000 Erreur ! Argument de commutateur inconnu.
  • Page 15 SAFE 2000/MAXI SAFE 2000 INSTRUCTION MANUALPage Erreur ! Argument de commutateur inconnu./15 Manual 00346609 replacing 00346608 990104 Erreur ! Argument de commutateur inconnu.
  • Page 16 RECOMMENDED DISINFECTANTS FOR USE IN CLASS II CABINETS FROM H OLTEN AMIN Note: Most disinfectants are mixtures containing several components. Avoid the use of products containing iodine, chloramine, chlorine dioxide, hypochloride, phenol, and perchloric acid. Useable disinfectants contain alcohol or aldehydes. Recommended disinfectants are 70% (volume) pure ethanol 2% (volume) glutoric aldehyde...
  • Page 17 LOG-BOOK Type : Product name : Serial no. : Supplier : Service interval : Laboratory : Service / Fault Notified Repaired Remark / fault Caused by / action Service Carried out repair occurred on / date / date internal/external...
  • Page 18 Service / Fault Notified Repaired Remark / fault Caused by / action Service Carried out repair occurred on / date / date internal/external...
  • Page 19 Service / Fault Notified Repaired Remark / fault Caused by / action Service Carried out repair occurred on / date / date internal/external...
  • Page 21 Heto EC-Declaration of conformity Holten Form.nr.: 00243167 DS/EN 45014 Annexe A (Recommended form for declaration of conformity) Heto-Holten A/S Gydevang 17-19, DK-3450 Allerød declare under our sole responsibility that the product Model: S 2000 / M 2000 to which this declaration relates is in conformity with the following standard(s) or other normative document(s): EN 292-1:1993 Safety of machinery (Basic concepts - General principles) EN 292-2:1993 Safety of machinery...