While the outside of the DPV may be above freezing, the battery may not. Ensure ample time is spent in a warm environment for thermal equilibrium across the pack before charging, following exposure to freezing temperatures. Genesis Manual Rev2.0 Copyright 2020, Nellis Engineering, Inc.
Page 4
DPV. Always remember to remove the recharge plug cover when not in use or the batteries may be permanently damaged by over discharge. Over discharge is not covered by the warranty! Genesis Manual Rev2.0 Copyright 2020, Nellis Engineering, Inc.
The Genesis batteries should only be charged when you intend to use the DPV. Charge them 12 to 24 hours before you plan to dive. When storing the DPV for more than a few days, the batteries Genesis Manual Rev2.0 Copyright 2020, Nellis Engineering, Inc.
Rotate the locking tab out of the way of the trigger when transitioning into a restrictive area or area congested Genesis Manual Rev2.0 Copyright 2020, Nellis Engineering, Inc.
Page 10
OFF position. If the motor continues to run and the DPV cannot be controlled, an option to stop the propeller rotation is to insert a non-life- Genesis Manual Rev2.0 Copyright 2020, Nellis Engineering, Inc.
Drain any water from the propeller coupling cavity and carefully reinsert the propeller. If you think you may have discharged the battery below 20% capacity, recharge the battery before storing the DPV as suggested in the Recharging section of the manual. Genesis Manual Rev2.0 Copyright 2020, Nellis Engineering, Inc.
Should they develop a white powdery film, clean them with a toothbrush or soft wire brush following a dive, as the powdery material will be softer when wet. The white powdery Genesis Manual Rev2.0 Copyright 2020, Nellis Engineering, Inc.
It will be significantly buoyant with the battery removed. 12. When finished, vent the body with the relief valve on the gauge assembly and remove it. Reinstall the test port plug and the screw next to battery connectors. Genesis Manual Rev2.0 Copyright 2020, Nellis Engineering, Inc.
Distance: 1.76 hrs x 60 min/hr x 175 fpm = 18480 feet or 3.5 miles If diving out and back, divide by 2 for distance each direction. *Actually maintaining the intended speed requires experience and should be practiced before a critical dive. Genesis Manual Rev2.0 Copyright 2020, Nellis Engineering, Inc.
Page 15
Speed to Power Estimate (single tank) 1200 1100 1000 Input Power vs. Static Thrust 1200 1100 1000 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 Thrust (lbs) Genesis Manual Rev2.0 Copyright 2020, Nellis Engineering, Inc.
5. Damage from modification, or attempted modification. 6. Damage from servicing by unauthorized individuals. 7. Nellis Engineering, Inc. will not be liable for any loss, damages or expenses, to include incidental, special, consequential or collateral damages, arising directly or indirectly from the sale or use of the equipment.
Need help?
Do you have a question about the Logic Genesis 2.0 and is the answer not in the manual?
Questions and answers