MIDORI -36 User Manual

Advertisement

Quick Links

User's Manual
-Models-
MIDORI-36, MIDORI-42, MIDORI-48, MIDORI-60, MIDORI-72
108 Pico St, Pomona, CA 91766 USA
Tel. (909) 865-7111
Fax. (909) 865-9222
www.YOSHIMASA.usa.com, info@yoshimasausa.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MIDORI-36 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MIDORI MIDORI-36

  • Page 1 User’s Manual -Models- MIDORI-36, MIDORI-42, MIDORI-48, MIDORI-60, MIDORI-72 108 Pico St, Pomona, CA 91766 USA Tel. (909) 865-7111 Fax. (909) 865-9222 www.YOSHIMASA.usa.com, info@yoshimasausa.com...
  • Page 2 5. Ensure that the fan is switched off from the supply mains before removing the guard. 1. Product Overview Our company produces the MIDORI air curtain, which can be used to ventilate domains with many years of accumulations of the core technologies. We have absorbed domestic and foreign advanced experiences fully in the foundation, and developed a new generation sequence product.
  • Page 3 Fixed supply voltage deviation, % 5. Installment The external dimensions and installation size (Inches): Minimum Height Model Above Doorway 8 ½ 9 ¼ 1 ⅜ MIDORI-36 35 ½ 4 ¹⁄₁₆ 13 ¾ 8 ½ 9 ¼ 1 ⅜ MIDORI-42 39 ⅜...
  • Page 4 6. Installing On Concrete Walls (1) According to the different specifications, choose the position (Picture 2) (2) Splits out explodes bolt's hole which matches M8 to pull on the position, will pull explodes the bolt to fix on the concretes wall, simultaneously should protect bolt's swinging radius is 19/32 in. (Picture 3) (3) With the gasket, the nut fastens the bottom;...
  • Page 5 5. If the width of the door is wider than the length of the air curtain, please use two or more assemblies. In this situation, please make sure the distance is about 25/32 in~1 ft. 37/64 in. 6. When installing the air curtain, please make sure the air curtain is hung on the wall plate and the wall cannot leave space.
  • Page 6 Input Wind Noise # of Volume Voltage Frequency Model Power Flow Speed (dBA) (lbs) Motors (CFM) Amps (Hz) (m³/h) (m/s) MIDORI-36 1450 ≤48 1450 ⅓ MIDORI-42 1450 ≤48 1450 ⅓ ⅜ MIDORI-48 1930 ≤49 1930 MIDORI-60 2420 ≤52 2420 ⅓...
  • Page 7 11. Service and Maintenance 1. The power should be cut off before inspection and maintenance. 2. Motors, electrical components should be moisture-proof to prevent a short circuit. 3. Every six months, carry out normal periodic repairs and maintenance to remove the dirt from air curtain. Please use cleaning detergents to clean, and then wipe with a clean, soft cloth.