PRODUCT MANUAL
Diver-MOD – AS339
Nijverheidsstraat 30,
6987 EM Giesbeek, The Netherlands
T +31 313 880 200
E info@eijkelkamp.com
I
www.eijkelkamp.com
M-11118002E

Advertisement

Table of Contents
loading

Summary of Contents for Van Essen Diver-MOD-AS339

  • Page 1 PRODUCT MANUAL Diver-MOD – AS339 Nijverheidsstraat 30, 6987 EM Giesbeek, The Netherlands T +31 313 880 200 E info@eijkelkamp.com M-11118002E www.eijkelkamp.com...
  • Page 2 Van Essen Instruments B.V. makes no warranty of any kind with regard to this material, including, but not limited to, its fitness for a particular application. Van Essen Instruments B.V. will not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
  • Page 3 I hereby declare that the equipment named above has been designed to comply with the relevant sections of the above referenced specifications. The items comply with all applicable Essential Requirements of the Directives. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 4: Table Of Contents

    Read Only Registers ........................17 Reading Diver Memory ........................ 18 Appendix C – Pressure Conversion Table ................... 22 Appendix D – Diver Equipment ......................23 Communication Cable ........................ 23 TD-Diver ............................23 © July 2017 Van Essen Instruments. All rights reserved.
  • Page 5 Baro-Diver ............................ 24 Cera-Diver............................. 24 Micro-Diver ........................... 25 CTD-Diver ............................. 25 Mini-Diver ............................. 26 Baro-Diver ............................ 26 © July 2017 Van Essen Instruments. All rights reserved.
  • Page 6: Introduction

    Compensated pressure is not available as this can be done by the back-end software. This manual outlines all the features and operating principles of the Diver-MOD. The next chapter gives an overview of the supported equipment, installation procedures and configuration. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 7: System Overview

    TD and Baro-Diver (model DI8xx),  Mini and Baro-Diver (model DI5xx),  Micro-Diver (model DI6xx),  Cera-Diver (model DI7xx), and  CTD-Diver (model DI27x). Detailed information about supported equipment can be found in Appendix D. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 8: Installation

    The default serial settings are 9,600 bps, no parity and 1 stop bit. If the serial settings are changed by Modbus function codes, the changes take place after repowering. The default Diver-MOD address is 1. If the slave address is changed by Modbus function codes, the change takes place immediately. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 9 Indicates the function code; e.g., read coils/inputs Data N × 8 Data + length will be filled depending on the message type Checksum At least 3½ character times of silence between frames © July 2017 Van Essen Instruments. All rights reserved.
  • Page 10: Transmission Mode

    1 less than what the register number is in this document. 3.1 Reg. 30002, 30012: Firmware Version and Serial Number Diver-MOD The firmware version and serial number of the Diver-MOD are stored in register 30001 and 30011 © July 2017 Van Essen Instruments. All rights reserved.
  • Page 11: Reg. 30220: Real-Time Barometric Data From Diver-Mod

    1 = 1,200 bps  6 = 38,400 bps  2 = 2,400 bps  7 = 57,600 bps   3 = 4,800 bps 8 = 115,200 bps  4 = 9,600 bps © July 2017 Van Essen Instruments. All rights reserved.
  • Page 12: Reg. 40003: Change Parity Of The Rs485 Port

    3 Read real-time values Register 3021x, convert to 0x04 30211 from all channels (float) single floats (two registers per single float) 4 Go to step 1 When used in a loop © July 2017 Van Essen Instruments. All rights reserved.
  • Page 13: Reg. 00002: Get Diver Data

    Register field Remark (registers) Force the Diver-MOD to 0x05 00004 0xFF00 Not required if the Diver was update the settings and connected during power up. data from the connected Diver © July 2017 Van Essen Instruments. All rights reserved.
  • Page 14: Reg. 00011: Start/Stop Logging Of Diver

    This register returns the remaining battery capacity of the connected Diver as a percentage of its full capacity. This value is only an indication! If the remaining battery capacity comes close to zero, the Diver needs to be replaced to prevent lost data! © July 2017 Van Essen Instruments. All rights reserved.
  • Page 15: Reading Diver Data

    For all supported Divers this is 400 cmH2O. The pressure reference can be read from register 30101. The returned value is a signed 16 bit integer, for example “400”. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 16: Time Series Data

    Each Diver data record consists of a timestamp, a pressure value, a temperature value and a conductivity value (CTD-Diver only). Each Diver data record is stored in the Diver-MOD in 4 registers as depicted in Figure 5. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 17 40041 from 0 to 35 in. Subsequently, the 2,000 records from the specified block can be read from register 32001 to 40000. A functional block diagram of this workflow is shown in Figure 6. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 18 Read 27 registers, starting at information register 30455, to get the timing header information. Set block number to read 0x03 40041 Set register 40041 to select <0-35> the block number to read. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 19 32001 8,000 records increments of 100 registers. Stop reading if one or more registers contain 0xFFFF. Continue reading data Increment j by 1. next 2,000 Diver records. Go to step 6. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 20: Appendix A - Specifications

    Real-time Diver conductivity (CTD-Diver only) pressure and temperature reading. Read Diver memory Read/write Diver sample interval Read/write monitoring point name of Diver Start/stop Diver (no future start) Read memory status: total memory and memory used © July 2017 Van Essen Instruments. All rights reserved.
  • Page 21: Pressure

    -20 to 80 °C Calibrated 0 to 50 °C Accuracy ±1 °C Resolution 0.2 °C maximum 5.7 Environmental Storage/Transport temperature -20 to 80 °C Storage humidity range 0 to 100 % © July 2017 Van Essen Instruments. All rights reserved.
  • Page 22: Appendix B - Diver-Mod Register Map

    Read 30102 Diver temperature reference SINT16 Read 30103 Diver reference conductivity SINT16 Read 30104 Diver pressure range SINT16 Read 30105 Diver temperature range SINT16 Read 30106 Diver conductivity range SINT16 Read © July 2017 Van Essen Instruments. All rights reserved.
  • Page 23: Reading Diver Memory

    The type of conductivity is either normal conductivity or specific conductivity at 25 °C depending on the setting in the CTD-Diver. 6.3 Reading Diver Memory For the Read input registers – 16 bit registers: (Registers for reading the Diver records) © July 2017 Van Essen Instruments. All rights reserved.
  • Page 24 Diver header Reserved channel 3 STRING Read 30446 (16 bytes) 30447 - Diver header Reserved channel 3 STRING Read 30454 (16 bytes) 30455 - Diver header Sample rate STRING Read 30461 (14 bytes) © July 2017 Van Essen Instruments. All rights reserved.
  • Page 25 40101: 1=Seconds, 2=Minutes, 3=Hours valid values register 40102: 1 – 59 40103 - Set real-time clock Diver UINT16 Read/write 40108 (Format register 40103 to 40108: YY, MM, DD, HH, MM, SS) © July 2017 Van Essen Instruments. All rights reserved.
  • Page 26 Number of Modbus Registers Registers Description Format Properties 40109 - Set Location Code Diver STRING Read/write 40118 (20 ASCII characters) 40119 - Set Instrument number Diver STRING Read/write 40128 (20 ASCII characters) © July 2017 Van Essen Instruments. All rights reserved.
  • Page 27: Appendix C - Pressure Conversion Table

    7 Appendix C – Pressure Conversion Table To convert from cmH2O to … Multiply by hecto Pascal (hPa) 0.980665 kilo Pascal (kPa) 0.0980665 millibar (mbar) 0.980665 inch of mercury (inHg) 0.028959020848 pounds-per-square-inch (psi) 0.014223343334 © July 2017 Van Essen Instruments. All rights reserved.
  • Page 28: Appendix D - Diver Equipment

    The TD-Diver is available in the following pressure ranges: 10 m, 20 m, 50 m and 100 m. Part no: DI8xx © July 2017 Van Essen Instruments. All rights reserved.
  • Page 29: Baro-Diver

    The Cera-Diver is available in the following Part no: DI7xx pressure ranges: 10 m, 20 m, 50 m and 100 m. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 30: Micro-Diver

    The CTD-Diver hade the following sample methods: fixed length intervals, event dependent, averaging and pumping test. Part no: DI27x The CTD-Diver is available in the following pressure ranges: 10 m, 50 m and 100 m. © July 2017 Van Essen Instruments. All rights reserved.
  • Page 31: Mini-Diver

    (316 L) casing has a diameter of 22 mm. The Baro-Diver can store a maximum of 24,000 measurements. Part no: DI500 Nijverheidsstraat 30, 6987 EM Giesbeek, The Netherlands T +31 313 880 200 E info@eijkelkamp.com www.eijkelkamp.com © July 2017 Van Essen Instruments. All rights reserved.

Table of Contents