Liquip Sales GPI EZ-8 Owner's Manual

Liquip Sales GPI EZ-8 Owner's Manual

Fuel transfer pump

Advertisement

Quick Links

DO NOT RETURN THIS
PRODUCT TO THE STORE!
Please contact Great Plains Industries, Inc.
before returning any product. If you are
missing parts, or experience problems with
your installation, contact our
Customer Support Department.
We will be happy to assist you.
800-835-0113,
316-686-7361
email:
gpisales@gplains.com

TABLE OF CONTENTS

General Information ............................................. 2
Safety Instructions .............................................. 2
Parts & Service .................................................... 3
Tools Needed ....................................................... 3
Contents Checklist .............................................. 3
Installation ........................................................... 4
Operation ............................................................. 6
Maintenance ........................................................ 6
Troubleshooting ................................................... 6
Speci cations ...................................................... 8
Warranty ............................................................. 12
921803-01 Rev F
EZ-8 & EZ-8 METHANOL FUEL PUMP
, Inc.
are
with
or
OWNER'S MANUAL
Check out the
Check out the
Great Plains Industries, Inc YouTube
Great Plains Industries, Inc. YouTube
channel to see Installation and Troubleshooting
videos for the EZ-8 Fuel Transfer Pump.
To the owner...
Congratulations on receiving your GPI
Pump. We are pleased to provide you with a system
designed to give you maximum reliability and ef ciency.
Your fuel pump is engineered, tested, and approved
for use with gasoline blends, diesel fuel blends and
kerosene (and methanol for the EZ-8 Methanol model).
Please take all due precautions when handling these
ammable liquids. Your safety is important to us.
Also, to assure the longest possible service life,
it is important that you follow the operation and
maintenance procedures outlined in this manual. We
are proud to provide you with a quality product and
dedicated support. Our commitment, together with
your conscientious use, will ensure years of safe,
dependable service from your fuel pump.
Victor Lukic, President
Great Plains Industries, Inc.
®
Fuel Transfer
05/16

Advertisement

Table of Contents
loading

Summary of Contents for Liquip Sales GPI EZ-8

  • Page 1: Table Of Contents

    EZ-8 & EZ-8 METHANOL FUEL PUMP OWNER’S MANUAL DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact Great Plains Industries, Inc. , Inc. before returning any product. If you are missing parts, or experience problems with with your installation, contact our Customer Support Department.
  • Page 2: General Information

    SAFETY INSTRUCTIONS The purpose of this manual is to assist you in in- Observe all safety precautions concerning safe stalling, operating and maintaining your GPI EZ-8 handling of petroleum fuels. or EZ-8 Methanol 12-volt DC pump, with manual To ensure safe operation, all fuel transfer systems nozzle.
  • Page 3: Parts & Service

    PARTS & SERVICE To obtain prompt, ef cient service, always be pre- pared with the model number of your pump, the In order to preserve the UL Listing for the motor, serial number or manufacturing date code of your do not attempt to service the motor. For products pump, and part descriptions and numbers.
  • Page 4: Installation

    INSTALLATION Step 4 Thread the suction pipe into the pump’s inlet t- INSTALL PUMP ON TANK ting and tighten until snug. Step 1 Step 5 NOTE: For EZ-8 with Spin Collar, wrap both Before installing the pump on the tank, clean the threaded ends of the tank adapter (B) 3 or 4 tank interior of all dirt and foreign material times with thread tape, and then insert tank...
  • Page 5 Step 4 Step 5 Place the nozzle into the nozzle holder on the end If the power cord provided is too long, using a util- of the pump motor housing. Note that the nozzle ity knife, cut to desired length. Using utility knife, cannot be placed in the holder unless the pump carefully strip 3 to 4 inches (7.5 to 10 cm) of outer switch is OFF (Figure 5).
  • Page 6: Operation

    OPERATION TROUBLESHOOTING Always follow safety precautions when oper- Always disconnect power before repairing or ser- ating this equipment. Review the Safety In- vicing the pump. Never apply power to the system structions. Before each use, repair leaks around when any coverplate is removed. seals or connections.
  • Page 7 Strainer Figure 12 • Bypass poppet binding or damaged. Re- move the bypass poppet, spring, and O-ring Figure 10 (Figure 13). Clean cavity. Inspect and replace • Suction pipe clogged, damaged, or missing. as necessary. Remove pump from tank. Inspect suction pipe.
  • Page 8: Speci Cations

    LOW FLOWRATE • Running too long in bypass mode. Limit by- pass operation to 5 minutes. • Fuel tank empty. Fill tank. • Strainer clogged. Inspect and clean as re- • Strainer partially clogged. Inspect and clean quired. as required. •...
  • Page 9: Illustrated Parts List - Ez-8 / Ez-8 Methanol

    ILLUSTRATED PARTS LIST - EZ-8 & EZ-8 METHANOL For Spin collar models Individual Parts Kits and Accessories Item Item Part No. Description Req’d. Part No. Description 137078-501 Motor, 12-Volt ............1 110037-1 Bushing, Tank Bung Adapter (Spin Collar Model) 904004-2 Screw, Hex Head Cap..........
  • Page 10 921803-01 Rev F...
  • Page 11 921803-01 Rev F...
  • Page 12: Warranty

    WARRANTY Great Plains Industries, Inc. 5252 E. 36 Street North, Wichita, KS USA To make a claim against this warranty, contact the GPI Customer Service 67220-3205, hereby provides a limited warranty against defects in material Department at and workmanship on all products manufactured by Great Plains Industries, 316-686-7361 or 800-835-0113.

This manual is also suitable for:

Gpi ez-8 methanol

Table of Contents