Page 1
Instruction for battery charger CD4212-2 Suitable for: This charger is specially designed for maintenance charging of batteries used in lifeboats. Type and Definition: 4212 — — Battery quantity Design No. Battery charger used on boat ship Indication: Red Lamp: alarm The red lamp will light up if it is open circuit, polarity reversed, short circuit, and there will be no output.
Page 2
Specifications: Supply voltage: 42V/AC 50/60HZ Fully charged voltage: 14.4V/DC Complementary voltage: 13.3V/DC ≤5A ( 2 pieces of battery) Charging current: Dimensions L×W×H: 243×134×80 (mm) Weight: 5 kgs Protection grade: IP56 Temperature: -25℃~55℃ Using Method: Connect in proper order: first, connect the battery, and then connect the power source: 42C/AC Trouble analysis: Troubles...
Page 3
Red lamp flashing 1. the output cable 1. Connect the connected reversibly to cable the battery. correctly. 2. The output open 2. Connect the circuited cable with connections with battery battery terminals are not terminal secure. securely. Warning! This unit can only be used to make maintenance and complementary charge.