Do you have a question about the 112-905 and is the answer not in the manual?
Questions and answers
Summary of Contents for NEW KON 112-905
Page 1
NEW KON ELECTRIC PERFORATORS Models 112-905・112-905L・112-605・112-705 Final 04.18.2018 Die-Block Pin Type Lever Type MODEL:112-905 / 112-905L 905L Die-Block MODEL: 112-605 / 112-705 ◆Specifications may change without prior notice for ongoing functional improvements.◆...
Please be sure to read these precautions carefully before use. MODEL 112 Perforator. Thank you for purchasing the For safety reasons, prior to operating this machine, please read these precautions and operating manual carefully. To use this machine correctly and in a safe manner, we added notifications to the following sections to further explain important information.
1. NEVER put your hands inside the machine as it may lead to bodily injury. 2. DON’T perforate materials other than paper as this might damage internal parts. 3. DON’T disassemble or modify the unit, otherwise injury or electrical shock may occur. 4.
1 . 1 . 2 . 2 . ➀ Main Switch The key switch turns on/off the power supply. ➁ Electric cord with plug Plug unit into a suitable wall outlet. ➂ Power lamp When the key switch is on, the power lamp will illuminate. ➃...
3 . 3 . ⑫ When switch is engaged by the edge of the paper, the machine will activate. Micro switch ⑬ Bolt for fixing the stand. Used for setting the die block on the main body. ⑭ Micro switch connector cables Connectors for attaching micro switch.
4 . 4 . ※ There are 4 types of die blocks….905, 905L, 605 and 705. ※ The maximum capacity is based on 64gs/㎡paper. Based upon paper thickness, number and diameter of the needles, the specifications may vary. e.g: the capacity may be less than the specified maximum. ※...
5 . 5 . Model 112 Series Electric Perforator Perforator Model Die Block Model 905L Type of Selection Letter PIN TYPE LEVER TYPE FIXED LETTER TYPE Fixed letters or marks Types of Perforations Dating or numbering・1 line PAID・Custom (including designed letters, logos, mark) 8 digits・10 digits Perforating Range 20 x 52 mm.
6 . 6 . ■Please read the following precautions carefully before using. Be sure to check and confirm that the power supply and voltage is correct as outlined in specifications. 2. When carrying the product, disconnect from the wall and please be sure to hold the bottom of the machine securely with two or more people (more than one person) and move.
7 . 7 . ■Precautions before use ※ Please be sure to install the perforator on a solid surface. ※ Perforators are very heavy. Please take caution while moving and setting up the unit with 2 or more persons. ※ Please don’t insert the key into the power switch ➀...
Page 11
■Basic operation method of perforating (common to all series) ※ This product has no power switch. Turn the key switch for turning on the power. (Status of power lamp and key switch when operating the unit) Light is off Light is on Light is on Key is on the left side.
8 8 ■ There is a microswitch to auto-activate the perforation cycle located on the depth gauge. (Upon paper insertion, the machine will activate automatically) ※ The position of the micro switch is set at the point of maximum depth when shipped from the factory. ■If you need to change the depth, please adjust according to the following procedure.
9 . 9 . ■ Following is the procedure to remove and install a die block. ※ Note: Be sure to turn off the power and unplug the power plug from the outlet before attempting repairs. TOOLS NEEDED:Phillips screwdriver. 6 mm L shape hexagonal wrench (Allen wrench) located in the accessory bag.
Page 14
【1】 【2】Lift up the top cover and put it aside Remove the 4 screws of top cover (left and right side). Note: please don’t remove the bottom screws. as picture. (Don’t remove the top cover from connectors). 【3】Remove the fixing screw of die block. 【4】Pull the die block 【5】Remove the connector out partially.
… 1 0 . … 1 0 . a: Is the power plug inserted into the AC outlet? Please insert the power plug into the AC outlet. a. No power. a: Is the fuse blown? (the power lamp is not lit) Please inspect and replace with the spare fuse.
1 1 . 1 1 . 1. Please check & empty the paper waste storage container prior to/during operation or on a regular schedule. Not emptying the waste regularly may cause needles to malfunction and the waste drawer not to be opened. Continuing to use the perforator may cause damage to the die block.
Need help?
Do you have a question about the 112-905 and is the answer not in the manual?
Questions and answers