Summary of Contents for LOGOMAT HSL CPU

  • Page 1: Table Of Contents

    Installation Guide CPU HSL Module Index Introduction Module Description Dimensions Safety Information Preventing electrostatic discharge Preventing risks of explosion Removing Power Supply Installation Installation Position Mounting Power Connection Connecting the inputs Diagram of simplified input circuit Input Wiring Diagram BUS Connection Using external storage RS232 Connections Technical Data...
  • Page 2: Introduction

    Read the instructions below carefully before performing any operation. This documentation is the property of LOGOMAT s.r.l.. Any total or partial reproduction of this document is prohibited without the explicit permission of LOGOMAT s.r.l.
  • Page 3: Module Description

    Module CPU HSL Description du Module BACK VIEW FRONT VIEW Ref. Description RS232 Port Connector for external storage XC1 Input connector Slot for marking module Additional BUS (34 pins flat cable) Module Power Plug Main Bus (34 pin flat cable) VIEW FROM BELOW DIN rail mounting guide DIN rail clamping side...
  • Page 4: Safety Information

    Module CPU HSL Safety Informations The module has been conceived for use in an industrial environment and must be installed according to the instructions included in this guide. In order to avoid dangerous situations and/or damage to objects and people, pay special attention and follow the instructions below.
  • Page 5: Installation

    Module CPU HSL Installation Installation Position During normal operation, the module may heat up. To allow for normal heat dissipation, the device must be assembled taking into account the minimum distances to walls, guards, cable trays and other devices. It is the responsibility of the installer to configure the electrical cabinet where the module is installed with forced ventilation systems or ventilation openings, so that the internal temperature does not exceed the maximum room temperature listed in the technical specifications.
  • Page 6: Power Connection

    Module CPU HSL Power Connnection The module is designed to be powered by a nominal voltage of 24Vdc or 18 Vac. Before wiring, make sure the power supply of the system on which the unit has to be installed is disconnected. WARNING! Any voltage supply higher or, in any case, with characteristics other than those listed in the technical specifications, may result in personal injury and property damage or malfunction of...
  • Page 7: Connecting The Inputs

    Module CPU HSL Inputs Connection 8 digital inputs are integrated into the CPU module All inputs are equipped with galvanic isolation by opto-couplers. WARNING! Pay attention during the wiring phases. Wire fragments or small metal parts could fall into the module and cause short circuits. IMPORTANT! ▪...
  • Page 8: Diagram Of Simplified Input Circuit

    Module CPU HSL 4. Once all cables are wired, assemble the connector. 5. Connect the connector to the CPU module Diagram of simplified input circuit Input Wiring Diagram Rev. Dec-2010...
  • Page 9: Bus Connection

    Module CPU HSL BUS Connection Connect the communication bus between the CPU and the I/O modules in the lower connector (BUS1). Connect the communication BUS between the CPU and the accessory modules in the upper connector (BUS2). BUS 2: Additional Bus BUS 1: Main Bus Using External Storage The PROM connector is used to insert an external EPROM storage containing the program of the PLC and...
  • Page 10: Technical Data

    Module CPU HSL Technical Data Specification Value Rev. Dec-2010...
  • Page 11: Notes

    Module CPU HSL Notes _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ Rev. Dec-2010...
  • Page 12 Module CPU HSL s.r.l. Via Bellini 6 (loc. Rastignano) Tel.: +39 051 6260070 40067 Pianoro (BO) Fax: +39 051 6260111 Italy info@logomat.it Rev. Dec-2010...