RECOMMENDATION FOR THE INSTALLATION

FEATURE

is designed for outdoor use. It powered by 12VDC, and has a built-in backup battery, The siren communicates
ZDSH-108
with the alarm panel to realize its multifunction, contains a high power horn and a flashing light with a colored lens
Model
Siren Tone
3
ZDSH-108
Model
SPL
ZDSH-108
118db

CONNECTION

To optimize the sirens yield, the length of the wiring should be not over 15 meters
OF
ZDSH-108
Flash
Multifunction Led
yes
yes
Static
Working
Current
Current
3mA
1,4A
Battery
Piezoelectric
12vdc/
-
1,3ah
Dimension
280x170x97mm
Picture 1:
Under the condition that without
battery, the terminal block of 12v
connect with the host 12v "+
-"power supply which with the
trigger , the ending resistor 820 ohm
connect with the 12v "+" and
"TRIG" of the alarm ,it is going to
trigger the siren to work , the power
supply of the host connect with the
host . Only under this condition, the
siren can be triggered.
1
Dynamic
Water
Level
yes
yes
Weight
Resonant
Frequency
1,2 Kg
0,5-3KHz
Power
supply
12vdc
Tamper
Switch
N.C.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZDSH-108 and is the answer not in the manual?

Questions and answers

Summary of Contents for ZUDSEC ZDSH-108

  • Page 1 RECOMMENDATION FOR THE INSTALLATION ZDSH-108 RECOMMENDATION FOR THE INSTALLATION FEATURE is designed for outdoor use. It powered by 12VDC, and has a built-in backup battery, The siren communicates ZDSH-108 with the alarm panel to realize its multifunction, contains a high power horn and a flashing light with a colored lens...
  • Page 2 RECOMMENDATION FOR THE INSTALLATION Picture 2: Siren connect with the battery, the “+” connect with “BAT”, “ - ” connect with the terminal block 12v “ -” , TRIG connect with the positive output power supply of the host ,the terminal block 12v “ - ” also should connect with the “...
  • Page 3 RECOMMENDATION FOR THE INSTALLATION Picture 5: The connect ways is the same like the picture 2 . The siren will be triggered when the output power is cut off. TERMINAL OF CONNECTION TERMINALS 12VDC+&-: they are the power terminals. TREMINAL TRIG: it’s the positive triggering terminal TERMINAL PGM: It’s a optional terminal, if the alarm panel has PGM function, the PGM terminal in the alarm panel should connect to this terminal.
  • Page 4 RECOMMENDATION FOR THE INSTALLATION FUNCTION OF DIP SWITCH 1.Time-lapse alarm switch Time-lapse alarm Directly 2.PGM control switch suggestive sound No sound 3 Battery connect switch Battery connect Battery disconnect 4 LED Led on Led off FUNCTION AND TEST 1. LED AND LAMP TEST Pick the DIP switch 1 in ON mood (the others also in ON mood), 12VDC power connected, the siren the siren sound"...

Table of Contents