Page 1
Translation of the Original Operating Instructions Micro-Application Head HB 11 FCH0479.2XM (Issue 11/2019) FCH0479-2XM_EN_191107.indd 1 07.11.19 14:03...
Safety instructions Safety instructions Possible dangers Danger! Never point the operational device at other persons. Danger due to high pressure! Danger of burns! The nozzle and melted hot melt adhesive can reach temperatures over 200°C. Wear heat protection gloves whenever contact is unavoidable. Danger due to vapours! PU hot melt adhesives give off harmful vapours (isocyanates) even when applied in accordance with instructions.
• heatable hose, especially the safety notes contained within. Operative range The micro application head HB 11 is used for the dosed discharge (dot or bead applica- tion) of hot melt adhesives with exchangeable nozzles (intended use). Technical data Model...
Assembly Electrical connection For the electrical connection, carry out the following steps: 1. At the tank system, switch off the heater of the output to which the application head will be connected. 2. At the controller/PLC, switch off the activation of the solenoid valve. 3.
2. Switch off the pump. 3. Allow the heatable hose to heat to operating temperature. 4. Screw on the heatable hose with connection (5) (see “Figure 2: Connections HB 11” on page 6) . While doing so, secure the application head with the open-end wrench size 14.
What happens if… What happens if… This chapter provides an overview of possible status and error messages and offers help on error correction In case of occurring functional disruptions, please first check • the power supply and the • compressed air supply for proper function as well as •...
Maintenance/servicing Maintenance/servicing Danger! Danger due to electrical voltage. All work which requires the device to be opened must only be carried out by qualified, electrically skilled personnel. Danger of burns! The nozzle and melted hot melt adhesive can reach temperatures over 200°C. Wear heat protection gloves for maintenance and repair work.
Maintenance/servicing Replace module HB 1 Required tools • 1 Allen key 3 mm • 1 open-end wrench 11 mm Figure 3: Replacement of module HB 1 Danger of burns! The module and melted hot melt adhesive can reach temperatures over 200°C. Wear heat protection gloves for the following work steps.
Disposal Figure 4: Insert O-rings 5. Check the supplied O-rings for completeness and correct fit (see Figure 4). 6. Position the module to the application head and screw on. 7. Screw on the nozzle at the nozzle foot of the module (Item (8) in Figure 2). It may be necessary to wait until the new module has reached the operating tempera- ture.
Bühnen GmbH & Co. KG We, the D-28277 Bremen declare on our sole responsibility that the product Applicator Head HB 11 to which this declaration refers, complies with the following Standards or normative documents in its supplied condition: EN 55014-1: 2012-05...