  • Page 1 Accessories for Air / Water Heat Pumps Outdoor installation Operating Manual Wall-mounted controller WR 2.1 83058800fUK...
  • Page 2: Table Of Contents

    .......8 Electrical connection ........8 Control panel ............9 Commissioning ..........10 10 Faults ..............10 11 Dismantling and disposal ......10 11.1 Dismantling ...........10 11.2 Disposal and recycling ........10 11.3 Removal of the buffer battery .....10 Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 3: About This Operating Manual

    Additional information, e.g. a tip on making work easier, information on standards Reference to further information  elsewhere in the operating manual or in another document ● Listing Secure connections against twisting Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 4: Contact

    Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 5: Residual Risks

    ● Electrical connection kit EVS or EVS 8 ● Domestic hot water tank ● Buffer tank ● Immersion heater Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 6: Components Of The Unit

    The nameplate contains the following information at the very top: ● Model, item number ● Serial number The nameplate also contains an overview of the most important technical data. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 7: Install The Hydraulic Connections

    ● Particle boards The board material must be dimensioned with sufficient thickness to ensure secure fixing. Appropriate fixing material must be provided on site for other types of wall constructions.  Hydraulic integration documents Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 8: Outdoor Sensor

    Route the wired plugs of the heat pump bus cable (②) and power cable (③) between the two rubber seals (④) and plug them into the corresponding socket in the wall-mounted controller. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 9: Control Panel

    4 RJ45 connection Modbus cable to Modbus distributor. Close the clamp and screw it tightly in place. Put on the front hood of the unit and screw it tight- ly in place. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 10: Commissioning

    Have the fault on the processor board of the control panel. message and unit number ( Nameplate) to  Dispose of the buffer battery in accordance with hand. local regulations. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 11: Technical Data / Scope Of Supply

    Free pressing Δpmax Δp Key: UK823281 Key: UK823281 “” “” Hot water flow rate Hot water flow rate ∆pmax ∆pmax Maximum free pressing Maximum free pressing “ ” [m Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 12: Dimensioned Drawings

    Technische Änderungen vorbehalten. Key: UK819494 Key: UK819494 All dimensions in mm. Spacing for drill pattern. All dimensions in mm. Spacing for drill pattern. Pos. Pos. Name Name Hole Ø6, for wall/floor plugs (accompanying package) Hole Ø6, for wall/floor plugs (accompanying package) Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 13: Installation Plan

    Name Legende: 819483- FS FS Free space for service purposes Free space for service purposes Alle Maße in mm. OKF Top edge of the finished floor Top edge of the finished floor OKF Oberkante Fertigfußboden Freiraum für Servicezwecke Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 14: Terminal Diagram 1/2

    Alternative OUT8 NTC2 2x0,75mm² GND2 NTC3 2x0,75mm² GND3 NTC4 2x0,75mm² GND4 TRLext NTC5 2x0,75mm² GND5 NTC6 GND6 NTC8 GND8 NTC9 GND9 2x0,75mm² Refer to protection notice ISO 16016. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 15 WR 2.1 Terminal diagram 2/2 UK 831246a Refer to protection notice ISO 16016. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 16: Terminal Diagram Mains Connection Heat Pump 3~400V

    Terminal diagram mains connection heat pump 3~400V WR 2.1 Refer to protection notice ISO 16016. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 17: Terminal Diagram Mains Connection Heat Pump 1~230V

    WR 2.1 Terminal diagram mains connection heat pump 1~230V Refer to protection notice ISO 16016. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 18: Circuit Diagrams

    Circuit diagram 1/4 WR 2.1 Direct connection /2.0 Control cabinet /3.7 /3.8 Refer to protection notice ISO 16016. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 19 WR 2.1 Circuit diagram 2/4 Direct connection Control cabinet /1.2 X10_PE2_3 / 3.4 X10_PE4_3 / 3.4 OUT1 AIN1 AGND1 AOUT1 Refer to protection notice ISO 16016. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 20 Circuit diagram 3/4 WR 2.1 NTC3 GND3 NTC6 GND6 NTC8 GND8 NTC9 GND9 X10_PE2_3 / 2.1 Control cabinet Control cabinet Refer to protection notice ISO 16016. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 21 WR 2.1 Circuit diagram 4/4 817478a Refer to protection notice ISO 16016. Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 22 Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 23 Subject to technical amendments without prior notice | 83058800fUK | ait-deutschland GmbH...
  • Page 24 GmbH Industriestraße 3 D-95359 Kasendorf www.ait-deutschland.eu...