  • Page 1 GSM SECURITY ALARM SYSTEM User Manual...
  • Page 2 System Overview Introduction Wireless GSM Burglar Alarm with voice prompt for commercial and home use is built on leading microprocessor technology with advanced GSM digital signal processing power. It is a highly integrated system of digital speech, mobile messages, multiple modes of wireless coding, long- distance home appliances controlling, SMS Messages identification and other technologies.
  • Page 3 To activate using remote control: press [ ARM ] key once. STAY ARM This is for partial arming of the alarm system when there are people at home, only some of the selected sensors are activated and could be triggered by events. In a STAY ARM status, the panel [ARM ] light is flashing.
  • Page 4 Flash one time for 3s GSM signals and SIM card are normal Installation of Panel Alarm Panel Initial Setup Load the SIM Card, connect telephone line, fix the GSM Antenna, connect the power and other cables if any, then power up alarm panel. The alarm panel voice prompt "Welcome to use alarm system", and start self-test the GSM network, “GSM Signal indicator ”...
  • Page 5 Add Remote Control: Press 【 SET 】 key 1s ,all defence zone indicator light would be on and voice prompt" add remote control " to enter the configuration mode: Then press any key of the remote control to send a signal to the alarm panel, voice prompt " learning successful", beep only once means the remote control has been configured before.
  • Page 6 Delete the sensor of sixth defence zone : press SET seven times ,and then press SET 3s when the sixth defence zone indicator light on ,the alarm panel beep twice , means delete the detector of sixth zone successfully . 4 Command Reference This system supports two methods of configuration including telephone set and SMS messaging.
  • Page 7 Syntax: 【3】 + 【1- Example: If you want to delete the first set of telephone alarm number, 6】+【#】 Method one: After entering the telephone remote setting status, press 31#. Method two: Send SMS message 123431# On the alarm panel, alarm panel reply "...
  • Page 8 Syntax: Example: the user needs to set the alarm delay time to 60 Seconds. 【 52 】 + 【 00-99 Method one: After calling and connected to the panel from remote, press Second】 + 【#】 5260#. Method two: Send SMS message 12345260# Set length of Siren Set alarm length of sounding when panel alarm, could be set to 0-20 sound...
  • Page 9 first To set the time for scheduled arm and disarm, Scheduled arm and Example: set up the first group scheduled time to arm at 22 : 00 pm and disarm time setting disarm at 07 : 00 am, this is valid for Monday, Tuesday, Wednesday, Thursday and Friday of each week.
  • Page 10: Enable Or Disable

    Syntax: mode. 1-5 represents one of the 5 zone type: 【61】+【07-10,zone number 】 + 【 1- 1.NORMAL 5 】+【0/1】+【0/1】+ 2.STAY ARM 3.INTELLIGENT 【#】 4.EMERGENCY 5.CLOSED The first 0/1 represents 0 siren of panel produce no sound upon alarming while 1 is sounded. The second 0/1 ,0 means NO and 1 means NC NO means short-circuit to alarm NC means open-circuit to alarm...
  • Page 11 Syntax: Method one: After calling and connected to the panel from remote, press120# 【12】+【0/1】+【#】 Method two:Send SMS message 1234120# Restore factory System restore factory setting setting Method one:After calling and connected to the panel from remote, press130000# Syntax: Method two: Send SMS message1234130000# 【13】...
  • Page 12 20+【#】 operation, password, delay alarming setting, delay arm setting, length of time of siren sounding, volume of siren, keyboard locking status, audible confirmation Example: Send SMS message 123420# to the alarm panel, the alarm panel replies with a list of related setting: Arming →...
  • Page 13 23+【#】 1:Normal On means the first zone is normal zone,siren on. 2:Stay Off means the second zone for STAY alarm, siren off 3: Smart On means the third zone for INTELLIGENT,siren on 4: Urgent On means the fourth zone for EMERGENCY,siren on 5: Off On means the fifth zone for CLOSE, in close state 6: Normal On means the sisth zone for NORMAL,siren on 7: Normal On NO means the seventh zone is NORMAL,siren on,and...
  • Page 14 Remote Control of Panel 5.1 After receiving the Panel Alert: After Panel alerts, it will automatically dial the preset telephone number for three times until connected ,and send SMS message to the preset telephone number . When the user picks up the phone, a piece of pre-recorded voice message will be played back immediately and let the receiver noted about the event.
  • Page 15 Type Zone Type Interpretation NORMAL Defense the Panel only works on the arming status. When disarming, Zone there is no response. STAY Defense zone can be shut off solely through the remote control (keyboard) (AT-HOME Defense to avoid the Infrared Detectors and other in-room detectors zone) from misinformation when master is resting at home.