Ⅰ、product description The quantitative leak to infrared sensor at the core, high-precision sampling AD, speed ARMCPU, making the sample data is more real, more reliable. The instrument uses a color LCD touch-screen display, user-friendly appearance, easy to operate. At present, some service providers are still using electricity electrochemical sensor principle of sulfur hexafluoride, SF6 sensors but this can not meet the test of the power industry SF6 low range, such 0-50PPM, there 0-3000PPM, but the infrared SF6 sensor principle can customize these...
1. 4.3" TFT touch screen design 2. 32-bit ARM MCU 3. Separately designed air way and circuit 4. Digital display of battery electric quantity 5. Good repeatability, high response speed 6. Automatic calibration of gradient 7. Color LCD display 8. Advanced probe protection function 9.
over-charging and over-discharging 11. Volume and weight: 372×266.5×134.5 (mm), 3.5kg Ⅳ、Appearance introduction The meter uses 4.3" TFT touch screen, which is easy and convenient to use with more beautiful appearance. The meter adopts 32-bit ARM MCU, which provides higher response speed and better measuring precision. Ⅴ、Features 1.
After the meter is powered on, a welcome interface will show on the meter. You can touch any place on the touch screen to enter the “sensor calibration interface”, or wait for 10 seconds and the system will automatically enter the “sensor calibration interface”.
After entering the “measurement interface”, you’ll see such touch buttons as [curve], [history], [save], [system] and [print]. Press the corresponding buttons to enter “measurement curve”, “history data”, “save data”, “system setting” and “print data”. Meanwhile, The curve interface is shown as follows: After entering the “measurement interface”, press [measure] to enter the curve interface.
Page 8
After entering the “history data interface”, you’ll see such touch buttons as [BACK], [NEXT], [Delete], [Format], [Measure] and [print]. In this interface, you’ll see the information about the previous and next history data. 2) Click [Delete], and the deleting prompt interface will be as shown in the following picture: Click [confirm], and if the deletion is successful, you’ll enter the following interface:...
Page 9
Click [confirm] to return to the history data interface. 3) Click [format], and the formatting prompt interface will be as shown in the following picture: Click [confirm], and if the formatting is successful, you’ll enter the following interface; or click [Return] to return to the history data interface. - 8 -...
Click [confirm] to return to the history data interface. 5. Save interface The save interface is as shown in the following picture: After entering the “save interface”, you’ll see such touch buttons as [confirm], [measure] and [print]. Press [confirm], and the system will automatically save data for you. If the data is successfully saved, you’ll enter the following interface.
At the time, touch [confirm] button, and the system will return to the “measurement data interface”. 6. System settings 1) The system setting interface is as shown in the following picture: After entering the “system setting interface“, you’ll see such touch buttons as [help], [demarcate], [settings], [set time] and [measure].
Page 12
According to the number of input password. This interface is intended for meter calibration and users are not recommended to use it. 3) Click “Settings”, and the meter will enter the “setting interface”. Click the symbols of up, down, plus and minus on this interface to set the backlight intensity and standby time.
button to save. 4) Click “set time”, and the meter will enter the “time setting interface”. Click the symbols of up, down, plus and minus on this interface to set the system time. After the setting is completed, click OK button to save. Ⅵ、Precautions This instrument is SF6 leak detector,The following points should be noted: 1.
the communication cable. the instrument and computer are assumed to be closed. Or the communication interface is easy damaged. 6. The instrument should be charged with enough electricity. It is required to check whether the electricity is enough or not frequently. Ⅶ、Packing List Name Host...
Page 15
quenched after finishing the battery charging. 2. When there is need for calibration and maintenance for the instrument? Generally speaking, it is recommended to calibrate every two years, or twice a year under special circumstances (when the gas route pollution is severe) 3.