Speaker abnormal detection and +B PROTECTION display
In case speaker abnormal detection or +B PROTECTION had
occurred, it can be check by pressing 'POWER' and 'X-BASS' button
twice.
Display will show "S** B**". S is referring to speaker abnormal detec-
tion and B is referring to +B PROTECTION. ** is in hex valve.
+B PROTECTION is condition when irregular process occur on power
supply line.
BEFORE TRANSPORYING THE UNIT
The following process need to be taken after set tapering/parts
replacement.
1. Press the ON/STAND-BY button to enter stand-by mode.
2. While pressing down the
press the ON/STAND-BY button until "CLEAR AL" appears.
3. While pressing down the
button, press the ON/STAND-BY button until "WAIT" → "FIN-
ISHED" appears.
4. Unplug the AC cord and the unit is ready for transporting.
button and the X-BASS/DEMO button,
button and the X-BASS/DEMO
/
2 – 4