Available languages

Connecting an electrical tool
The appliance has been equipped with an electronic outlet for connection of your electrical equipment. The
appliance is switched on automatically the moment you switch on the electrical tool.
Connect the hose (1) directly to the dust extraction outlet of the electrical tool.
Insert the mains plug of the electrical tool into the outlet (9).
WARNING: The maximum rating for an appliance operated from the auxiliary power supply is 2000 W.

6. OPERATION

Make sure the power cord has been fully unwound before you switch on the appliance. The air leaving the
grids must not be hindered.
When using the appliance in combination with an electrical tool, switch on the appliance first to the II
position and then the electrical tool. The vacuum cleaner is switched on together with turning on the
connected electrical tool. After switching off the tool the vacuum cleaner is working for a few seconds.
Use the universal nozzle for vacuuming up dust from large surfaces. To keep delicate materials free from
scratches, replace the flat adapter (5a) for the brush adapter (5b) into the universal floor nozzle.
Use the crevice nozzle for vacuuming up dust from narrow and confined spaces.
Use the brush nozzle for vacuuming up dust from furniture.
When vacuuming up liquids, make sure the nozzle is not fully submerged in the liquid to be vacuumed up.
Clean the appliance after use according to instructions and wind the power cord around the shell.
Switching on and off (Fig. I and J)
To switch on the appliance for use without an electrical tool, set the on/off switch (8) to "I".
To switch on the appliance for use with an electrical tool, set the on/off switch (8) to „II" (AUTO).
To switch the appliance off, set the on/off switch (8) to "O".
Vacuuming up waste material and dust
Check whether the dust filter (19) has been FITTED.
Mount the tube (4) to the handgrip (3).
Vacuuming up dust released from an electrical tool
Check whether the dust filter (19) has been FITTED.
Connect the hose (1) directly to the dust extraction outlet of the electrical tool.
Vacuuming up liquids
Check whether the dust filter (19) has been REMOVED and attach the sponge filter (21) instead.
Make sure the inside of the collector (15) is clean and free from dust.
Mount the tube (4) to the handgrip (3).
Emptying the collector
Switch off and unplug the cleaner.
Release the clamps (11), remove the motor unit (13) from the collector (15).
Empty the collector (15).
Blowing
• In order to blowing mount flexible hose (1) into the neck of the blower (10) and turning the lock.