Download Print this page

JP 4F400212C01 Technical Description, Installation, Operation And Maintenance Instructions

Fuel stove and air integrated parkingheater

Advertisement

Quick Links

Fuel stove and air integrated parking heater
Technical Description, Installation, Operation and Maintenance Instructions
Production Type
Double stoves Diesel DC12V
Single stove Diesel DC12V
Idle cooking is forbidden
Order No.
4F400212C01
4F400212C21
Jan. 25th,2022

Advertisement

loading
Need help?

Need help?

Do you have a question about the 4F400212C01 and is the answer not in the manual?

Questions and answers

Summary of Contents for JP 4F400212C01

  • Page 1 Fuel stove and air integrated parking heater Technical Description, Installation, Operation and Maintenance Instructions Idle cooking is forbidden Production Type Order No. Double stoves Diesel DC12V 4F400212C01 Single stove Diesel DC12V 4F400212C21 Jan. 25th,2022...
  • Page 2 Thank you for using the parking heater This manual describes the technical description, installation, operation and maintenance instructions for the parking heater. To ensure the correct use of the heater please read this manual carefully before installation and use. Please keep it properly after reading it. For review.
  • Page 3: Main Technical Data

    parked in a closed room, in an enclosed space 1.Application (such as a garage, repair shop), the exhaust gas Air and stove heater (hereinafter referred to as from the fuel stove can be toxic.Therefore, in the fuel stove) is an integrated stove, heating the enclosed space to turn off the fuel supply of air as one of the special RV fuel stove.The the fuel stove, through the control switch to...
  • Page 4 dry boiler burning. Fig.1 1-Heater 2-Buffer 3-Fuel pump 4-Fuel pipe (blue:fuel tank to fuel pump) 5-Fuel filter 6-Fuel suction pipe 7-Fuel pipe(white: heater to fuel pump) 8-Check valve 9-Air inlet pipe 10-Air filter (optional) 11-Fuse holder 12-Exhaust pipe 13-Fireproof cap 14-Control switch 15-Fuel pump lead wire 16-Power cord17-Insulated sleeve Schematic diagram of fuel stove installation.As shown in figure 2.
  • Page 5 with accessories of this machine. Opening size of diesel cooking stove The connection between the intake pipe and exhaust pipe and the main engine shall be fastened on the combustion inlet and exhaust pipe with matching clips.The outlet of the exhaust pipe should be positioned so that the discharged gas is not taken in by the intake pipe or the car heating fan (i.e.
  • Page 6 The fuel is extracted from the vehicle fuel tank, lines must be protected against mechanical and the fuel is transported and adjusted through damage.The laying of fuel pipeline will not a special fuel pump (provided by the adversely affect the stability of vehicle rotation manufacturer).Fuel is not allowed to be and engine operation.Protect fuel carrying parts extracted from the vehicle engine's return...
  • Page 7 The height difference between the fuel level Installation of fuel suction pipe(Fig9) and the pump, and the height difference between the pump and the main engine inlet, will generate pressure (or suction) in the fuel path, so these dimensions should be in accordance with the requirements in Figure 7 (in a closed tank, negative pressure will be generated, in which case, the minimum fluid...
  • Page 8 Wiring diagram Fig11 metal surfaces, exhaust pipes or hot air pipes. Insert the control switch cable plug into the DC12V power supply corresponding position as shown in Figure 4. The electrical wiring, switches and control The red and green light at the same time on and equipment for the fuel stoves must be located off after power on .
  • Page 9 6. Operation instructions and be in the state of failure lock.At this point, you can turn off the fuel stove more than 5S to Start fuel stove restart by pressing function button. Operate with a special knob switch. Fuel stoves may cause circuit faults due to the If cooking function is needed, long press the following reasons: joint corrosion, poor contact, function button over 2S and the cooking...
  • Page 10 Troubleshooting methods of fault lock Fault Flash fault handling Method of troubleshooting code frequency A Check the fuel supply system B. Check whether the combustibles inlet and Start failure outlet are blocked C Check the electric plug and flame sensor A Check the fuel supply system B.
  • Page 11 Troubleshooting methods of fault lock Flash Fault fault handling Method of troubleshooting code frequency Combustion fan broken circuit A Check the combustion fan A. Check the motor lead Combustion fan failed to start connection B Check the combustion fan Fan speed is too low A Check the combustion fan A Check the supply voltage B check the glow plug temperature...
  • Page 12 8. Notes Check the fuel line for leaks. ● Long-term shutdown ● First installation -- When the fuel stove is not in use for a long - The first installation of the fuel stove, in order time, it should be operated once every 4 weeks to completely remove the air in the fuel supply for about 10 minutes each time to prevent system, so that the fuel pipeline filled with fuel,...