Removing The Turbocharger - ABB HT574226 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-M axial
2
Removal and installation
2.2

Removing the turbocharger

Risk of tipping
If the turbocharger is not sufficiently supported or not supported at all during
removal and installation, it may tip over and cause severe injury to personnel
WARNING
or accidents resulting in fatalities.
Support the turbocharger at a suitable location.
Secure with lifting gear wherever possible.
Wear safety helmet.
If present: Loosen cable to speed sensor.
Disconnect all gas, air and lubricating oil pipes.
Figure 6: Turbocharger suspension points
If present: Remove insulation segments on bearing casing and feet.
Attach lifting gear to the suspension lug of the bearing casing and through the boles on the
turbine-end foot.
© Copyright 2016 ABB. All rights reserved.
HZTL4033_EN
Page 10 / 113
Revision A
July 2016