Back side

1. Product Data

Radio Frequency
2.4GHz
Input Voltage
EU: AC200-240V, 50/60Hz
Output Voltage
EU: AC200-240V
Max Load
3680W @ 230V (resistive load)
Max Current
16A
Power Consumption
<2W
Ambient Temperature
0°C to 40°C (during operation)
Set Temperature Range
0°C to 40°C
Hysteresis
0.5°C to 2°C (default 0.5°C)
1. NTC/10K B(25/50℃)=3950 (default)
2. NTC/15K B(25/50℃)=3950
Floor sensor type
3. NTC/50K B(25/50℃)=3950
4. NTC/100K B(25/50℃)=3950
5. NTC/12K B(25/50℃)=3950
OFF, HEAT, ENERGY HEAT, AWAY, DRY
Control Mode
Control type means which temperature sensor the device refers to
when it adjust temperature.
Room sensor: adjust temperature refers to room temperature
(factory default type).
Control Type
Floor sensor: adjust temperature refers to floor temperature.
Room+Floor sensor: adjust temperature refers to both room
temperature and floor temperature.
Current ≤ 13A - 1.5mm² wire
Wiring Requirement
Current > 13A to 16A - 2.5mm² wire
IP Rating
IP21
Control Pollution Degree (Method D)
pollution degree 2
Rated Impulse Voltage (Method D)
4kV
Relative Humidity
8% to 80%
Dimensions
80x80x52mm
CE,
LVD: EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1
EMC & RF: EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019,
EN 60730-1:2016+A1:2019, EN 60730-2-
Approvals
19:2019+A1:2019+A2:2020, EN 50663:2017;ETSI EN 301 489-
1V2.2.3, ETSI EN301 489-3V2.1.1
ETSI EN300 220-1 v3.1.1., ETSI EN300 220-2 V3.2.1
RED certificate: 2014/53/EU
• The Zigbee HVAC controller is a wireless thermostat for heating system, which complies to Zigbee 3.0
wireless protocol standards. The thermostat has 4 operation modes which can be controlled manually and
locally or through remote controlled through Zigbee gateway controller.
• All setup is performed via supported IEEE 802.15.4-based control platforms and other Zigbee3.0 compatible
control systems. Appropriate gateway control software allows for adjustment of control mode, control type,
schedule etc.
• Sensors: Air temperature
• THERMOSTAT MODE: OFF, HEAT, ENERGY HEAT, AWAY, DRY
• Measurement range: –10°C to +60°C
• Accuracy: ±0.1°C
• WARNING: Electrical power must be switched off during installation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ROB-200-040-0 and is the answer not in the manual?

Questions and answers

Summary of Contents for ZIGBEE ROB-200-040-0

  • Page 1 L N N RED certificate: 2014/53/EU • The Zigbee HVAC controller is a wireless thermostat for heating system, which complies to Zigbee 3.0 wireless protocol standards. The thermostat has 4 operation modes which can be controlled manually and locally or through remote controlled through Zigbee gateway controller.
  • Page 2 Automatic (Energy Save Mode): the device will control the heating system according to the configured time remind “Time setting error!!!”. The default time schedules are as follows: schedule, or the mode can be configured by Zigbee gateway but the temperature can not be modified and sent Monday ~ Friday...
  • Page 3 reported to the associated devices, meanwhile the buzzer or vibrator will beep 3 times every 10 seconds. The 7:30,24℃ ~ 12:00,20℃ over heat alarm function can be disabled, which can be set directly through the device. Or can be configured 18:00,16℃...
  • Page 4 If set as “default”, device will go to default mode after power on again. Factory resetting will remove the device from Zigbee network and all parameters will be restored to factory This status can also be configured through the proprietary attribute PowerUpStatus (0x1004) of Thermostat default setting, all bindings will be cleared.
  • Page 5 The thermostat provides 3 zigbee application endpoints: ManufacturerName string, 0x0004 read-only “Sunricher” Endpoint Application Profile string, ModelIdentifier 0(0x00) 0x0000(ZDP) ZigBee Device Object (ZDO) – standard management features 0x0005 read-only “Zg9092” 1(0x01) 0x0104(HA) Device ID is 0x0301(Thermostat ). DateCode string, 2(0x02) 0x0104(HA) Device ID is 0x0007(OTA). 0x0006...
  • Page 6 int16S , reportable OutdoorTemperature SceneValid bool, 0x0001 read-only This is floor temperature, the maximum resolution this format allows is 0.01 ºC. 0x0003 If true, the scene identified by CurrentGroup and CurrentScene is currently read-only active, i.e. all device attribute values match the values in the scene field set. Occupancy bitmap8 , When this flag is set as 1, it means occupied, OccupiedHeatingSetpoint will be...
  • Page 7 FloorSenserCalibration MeasurementType INT8S, bitmap32 , 0x1005 0x1224 The temp compensation for the external (floor) sensor, range Indicates the physical entities that this devices is able to measure. Supports 0x0000 reportable read-only is -30-30, unit is 0.1°C. default value 0 only bit0: Active measurement (AC) DryTime int16U , INT8U...
  • Page 8 • Power wires: connect Line & Neutral wires to L & N terminals labeled “IN” 1st January 2000. Refer to [Z2] for ZigBee specification of the time cluster. • Heater wires: connect Line & Neutral wires to L & N terminals labeled with “heating element” graphic The metering device will use this clusters as a client –...

Table of Contents