Usage and Installation Manual for Automatic Cover Water Removal System c o v e r s t a r . c o m c o v e r s t a r . c a l a t h a m p o o l . c o m...
Page 2
Usage and Installation Manual for AutoDrain Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . 2 General Operation .
Page 3
LATHAM POOL PRODUCTS, INC. USAGE AND INSTALLATION MANUAL FOR AUTODRAIN PUMP IMPORTANT! PLEASE READ CAREFULLY AND COMPLETELY BEFORE BEGINNING INSTALLATION. INTRODUCTION TOOLS REQUIRED • Hammer Drill Thank you for purchasing the AutoDrain • #2 and #3 Phillips and Standard Screw Drivers Automatic Cover Water Removal System.
SAFETY INFORMATION CAUTION ATTENTION Connect only to a circuit protected by a Class A Ground Ne branchez qu’à un circuit protégé par un disjoncteur Fault Circuit interrupter. différentiel de fuite à la terre de classe a This device must be installed in accordance with national AVERTISSEMENT and local electrical codes and should be installed by a Cette pompe n’est destinée qu’au drainage de couver-...
Page 5
Step 2: Assemble the Pump Head and Extension Tubing a) Uncoil the wire that is attached to the PUMP HEAD. Uncoil the 5/8" HOSE. Attach the 5/8" HOSE to the PUMP HEAD at the connection fitting . b) Feed the wire and the hose through the following parts in this order: •...
Page 6
Step 3: Install the Pivot Mount Assembly a) Remove the lid from the automatic cover housing. b) Be careful when mounting the Pivot Mount Assembly. The AutoDrain system only installs in one direction . See diagram below for correct orientation. Position the Pivot Mount Assemby so the Pump Head will be positioned near the side of the pool.
Page 7
c) Mount the Pivot Mount Assembly to the back wall of the automatic safety cover housing with a 1" clearance between the top of the front wall of the automatic safety cover housing and the underside of the Pivot Mount Assembly .
Page 8
Step 4: Install the Stop Bracket a) Position the Pump Head so that it is in the retracted position being careful not to let the Pump Head fall behind the pool cover . b) Mount Stop Bracket to the back wall of the automatic safety cover housing. c) Adjust the Stop Bracket to stop the Pump Head at the desired location under the automatic safety cover housing lid .
Page 9
Step 7: Power Supply a) Mount the power supply box according to your local electric code. b) Orient the power box so that the MOUNT THIS WAY UP Arrow is pointing upward for proper drainage of the power supply box and mount according to your local electric code. c) Ensure power is off to the circuit that is being connected.
Page 10
NOTES: 9 AutoDrain Pump Usage and Installation Manual...