Copies of this instruction manual are available upon request. The Gharieni Group GmbH shall not be held responsible for any damages, direct or indirect, caused to people, animals or objects resulting from negligence or non-compliance with the instructions contained herein.
Page 5
result in minor or moderate injury. DANGER! To reduce the risk of electrocution: 1. All electrical work to connect the PS to the mains must be carried out by a qualified professional. Do not modify the energy supply. The connection must be carried out in accordance with the current local and legal regulations.
15. Always keep children away from the PS. Children must not play with the PS or its single components. 16. This device is not intended to be operated by persons with reduced physical, sensory and mental capabilities or lack of experience or knowledge, unless they are supervised or instructed concerning the use of the device and do understand the danger resulting thereof.
DANGER! THIS DEVICE MUST BE INSTALLED BY GHARIENI´S TECHNICAL SERVICE STAFF OR TECHNICAL SERVICE STAFF AUTHORIZED BY GHARIENI ONLY! NEVER TRY TO CARRY OUT THE INSTALLATION OR SINGLE STEPS OF THE INSTALLATION YOURSELF. DO NOT ALLOW UNAUTHORIZED SERVICE STAFF TO CARRY OUT THE INSTALLATION OR SINGLE STEPS OF THE INSTALLATION.
4.1 Checklist before installation Use this checklist to verify that you have all the information you need from your consultations. The following items are particularly important: The customer has to provide for access to the affusion pipe as well as to the water connections and electronic components.
5. GROUNDING INSTRUCTIONS DANGER! This product must be grounded properly. In the event of an electrical short-circuit, grounding reduces the risk of electric shock by providing a path of low resistance for the electric current. The grounding must be carried out in accordance with all current legal and local regulations.
DeLuxe Automatic filling (1 x via WaterFall with Pearl Stream) SPA-Programme Relax Affusion pipe SPA-Programme Vitalize 7. PLANNING INFORMATION 7.1 Plumbing 1. Connect the water supply (HW+CW) 2x DN 15 - G1/2" via angle valves with the filter (included in delivery).
7.3 Water hardness The recommended water hardness is 5-6 e. Use water softening system into the feed pipes depending on water hardness. 7.4 Water heating To choose the perfect hot-water storage tank - taking additional tapping points and simultaneous usage into consideration - it is essential to assess the specific demand (e.g.
1. earth-leakage circuit breaker (30 mA, 2-pin, type A) 2. safety cut-out (6 A, type B) 3. circuit-breaker switch (16 A, 1 make contact, 230 VAC). 7.9 Space requirement seat basin Sufficient free space around the device is required. See above drawing. Remember that you need additional free space around the above dimensions for treatment.
8. OPERATING INSTRUCTION 8.1 Description/details of the PS Manually-adjustable headrest by approx. 25 forwards. Electrically-adjustable (via MCP) backrest from approx. 26 to 75 The height of the seat is electrically-adjustable (MCP) from approx. 63 to approx. 93 cm. Electrically-movable (via MCP) forwards and backwards by approx. 17 cm. Electrically-inclinable (via MCP) backwards by 14 The height of the footrest is electrically-adjustable by 20 cm.
8.2 Manual control panel WARNING Always ensure that no parts of the body can be crushed while operating the MCP. RISK OF CRUSHING! 1 black Entire seat up/down. grey Default position for head treatment (left)/feet treatment (right). 2 black Inclination of the backrest. grey Lifting column and footrest are moved simultaneously.
(within 1 second) the shift button. Keep on holding both buttons for at least 2 more seconds until you hear an acoustic signal. 8.3. Mixing valve PediSpa Basic only. with backflow protection 2*connection AG 1/2" (cold/warm) 1*outflow AG 1/2"...
3. The water supply must be equipped with a remote pressure balancing valve to protect your customer from dangerous changes of temperature. For the specific equipment of your PediSpa, please refer to chapter 6.1. Automatic filling up to the ankles.
8.5.1 Rotary knobs Quantity of water Water temperature 8.5.2 Display on/off Via rotary knob Via display Use of the jets The eccentrics will close when the jets are activated manually; then the water is supplied automatically. As soon as a sufficient water level has been reached, the...
water supply stops and the jets start operation. When pressing the jets-key again, the jets stop operation. 8.5.3 Quantity of water/temperature setting Quantity of water setting Water temperature setting Suspension of the protection from scalding. Turn rotary knob to MAX. Turn and push rotary knob simultaneously.
8.5.4 How to start a programme You can vary the water temperature by +/- 2 C and the quantity of water by +/- 20% while a programme is running. You can cancel a running programme prematurely by pressing the rotary knob or display-keys.
9. TECHNICAL DATA 9.1 Plumbing Flow rate at 3 bar flow pressure (max.) Affusion pipe 13.6 l/min. Flow pressure Minimum flow pressure 2.5 bar Maximum flow pressure 4.0 bar Maximum difference in flow pressure 1.0 bar between hot and cold water Recommended flow pressure 3.0 bar FOOT BATH...
9.3 General Weight of the entire PS approx. 210 kg Ambient temperatures Basin max. 55 Basin min. 5 Control elements max. 35 Control elements min. 5 Storage max. 35 Storage min. 5 Store somewhere dust-free and dry! Provided by the customer Minimum space requirement for power supply unit in min.
WATER FALL with PEARLSTREAM connector-installation, preinstalled. Ground fastening material. Plastic Bath-Liner 285*390*20 mm, non-slip. Connection material Power supply cable, 15 m System-control unit. Connecting lines, mounted cable for control unit (1*2.9 m, 2*0.6 m). 2*pressure hose 1/2"*1/2"*300 mm. ...
9.7 Electronic drain and overflow In-wall parts Preinstalled with leaking-water connection of the system distributor. Drain 40/50 mm Water separator. IP X4. Draining capacity: 0.87 l/s. Overflow capacity: 0.63 l/s. 9.8 Control units Electronic control units (SMART TOOLS) external panelling parts ...
NOTICE! In case of doubt or when you do not exactly know what to do, please contact the Gharieni Service Department. 10.1 Base and basin 1. The base and basin are made of Corian®. The base and basin should be cleaned regularly to keep the PS in proper condition.
In case of any malfunction, please contact the Gharieni Service Department. 11. GUARANTEE PROVISIONS The Gharieni Group GmbH supplies all new equipment subject to a 3-years guarantee. Wearing parts (such as e.g. incandescent lamps, UV lamps, glass panels, consumables etc.) are not covered by this guarantee. Damage or loss due to unprofessional or improper use, non-compliance with the provisions of the instructions for use and/or gross negligence is not covered by guarantee either.
Claims must be filed within 8 days after the delivery of Gharieni PediSpa. Apart from the cases specified in the supply agreement, the guarantee is void when: The malfunctioning is attributable to the operator.
14. EC-DECLARATION OF CONFORMITY EC DECLARATION OF CONFORMITY Gharieni Group GmbH (Manufacturer) Gutenbergstraße 40; D-47443 Moers; Germany declare that the product PediSpa (Type or model; name) is produced in accordance with the requirements specified in Low Voltage Directive (LVD) 2006/95/EG,...
Page 29
RESERVED. ITS REPRODUCTION OR TRANSMISSION TO THIRD PARTIES IS FORBIDDEN WITHOUT THE AUTHORISATION OF THE OWNING COMPANY. THE POWER TO PROTECT ITS RIGHTS IS RESERVED AND OFFENDERS SHALL BE PROSECUTED Gharieni Group GmbH Am Schürmannshütt 24 D - 47441 Moers...