  • Page 1 Heat Strip Installation Kit Model: Instruction Manual C-FACR15SA-A02 * Picture shown here is for reference only.
  • Page 2: Table Of Contents

    Thank you and congratulations for purchasing this Furrion product. Before operating your new product, please read these instructions carefully. This instruction manual contains information for safe use, installation and maintenance of the product. Please keep this instruction manual in a safe place for future reference. This will ensure safe use and reduce the risk of injury.
  • Page 3: Before Use

    What’s in the Box Make sure the unit and the accessories are in the box. If anything damaged or missing, contact your dealer. Component Description Quantity Model C-FACR15SA-A02 Heat Strip Screw ST4x9 mm Washer Ø4*Ø9*0.8mm “HEAT” Icon Sticker Connecting Harness...
  • Page 4: Installation

    Installation DANGER Electric Shock Hazard ● Disconnect power or shut off the air conditioner circuit breaker before installation. ● Failure to do so can result in electric shock. WARNING Installation of the heat strip must be carried out by a professional/certificated technician only.
  • Page 5 holes on each side. (Fig. 7) 9. Insert four screws with washers into these holes. And then fasten them. (Fig. 7) Evaporator Fig. 4 6. Remove the two filters by pulling the tabs to release. (Fig. 5) Heat Strip Fig. 7 NOTE: Use ST4 x 9mm screws (provided) only.
  • Page 6 12. Install the top cover of the rooftop unit back and fasten the 10 screws removed in step 1. Wire Connection White Wires DANGER Electrical Shock Hazard ● Disconnect power before servicing. Fig. 11 ● Failure to obey this warning could 16.
  • Page 7: Operation

    Fig. 15 For those already with silk screen Fig. 14 HEAT(OPTIONAL), omit this step. (Fig.16) 19. When the heat strip is connected to the control box, reverse above steps to install the electrical box, refer to your trim kit for final installation of your AC, or reverse the steps taken to dissemble your trim kit body.
  • Page 8: Specifications

    Avoid excessively long usage periods to prevent overheating. Consider using the furnace to bring the temperature up first, then maintain with the HEAT mode. Specifications Model C-FACR15SA-A02 Heating Capacity 1,500W Operation Ambient 19°F~86°F (-7°C~30°C)
  • Page 9 • 52567 Independence Ct., Elkhart, IN 46514, USA • Toll free:1-800-789-3341 • Email: support@furrion.com ©2007-2020 Furrion Ltd. Furrion and the Furrion logo are trademarks licensed for use by Furrion Ltd. and ® registered in the U.S. and other countries. IM-FHA00075 V1.0...