NOTE: (When Installing)
Make sure to confirm the following points when installing:
• The screw is tightened enough.
• Installing conditions are fine. (No distortion, no abnormal-
space.)
• No dust and/or dirt on lens surfaces.
• LCD image is fine. (No dust and/or dirt on it, and no gradient
images.)
(Fig. D32)
9.4.

Lens Disassembly Procedure

Precaution:
1. Do not remove the MOS Unit when disassembling or
reassembling the lens in order to maintain it clean.
When remove it, refer to item "9.6.".
2. Keep dust or dirt away from the lens.
To remove dirt or dust from the lens, blow with dry air.
3. Do not touch the lens surface.
4. Use Lens Cleaning Kit (VFK1900BK).
9.4.1.
Removal of the Zoom Motor and
Lens FPC Unit
1. Peel the FPC Tape A and FPC Tape B.
2. Unscrew the 2 screws (A).
3. Unscrew the screw (B).
4. Remove the Photo Sensor.
5. Disconnect 2 connectors.
6. Unlock the locking tab and remove connector portion.
7. Remove the 2 convexes.