bierkuhl BOS Cleantec IR duct inspection robot Operation And Maintenance Manual

Advertisement

Quick Links

®
BOS
IR duct inspection robot
Operation and maintenance manual
Operating instructions must be read carefully before using the device. This is
important for correct and safe operation of the device!
BOS® Cleantec
Bierkühl Oy
Pellonlaita 1, 50600 Mikkeli Finland
+358 440 178 111
www.boscleantec.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BOS Cleantec IR duct inspection robot and is the answer not in the manual?

Questions and answers

Summary of Contents for bierkuhl BOS Cleantec IR duct inspection robot

  • Page 1 BOS® Cleantec ® IR duct inspection robot Operation and maintenance manual Operating instructions must be read carefully before using the device. This is important for correct and safe operation of the device! Bierkühl Oy +358 440 178 111 Pellonlaita 1, 50600 Mikkeli Finland www.boscleantec.com...
  • Page 2 Operation and maintenance manual BOS® Cleantec ventilation duct inspection Ø READ ALL SAFETY AND OPERATING INSTRUCTIONS! Ø KEEP THE MANUAL FOR FUTURE USE! Failure to follow the warnings and instructions could result in electric shock, fire and / or serious injury! This manual only applies to BOS IR duct inspection robot.
  • Page 3: General Regulations

    Operation and maintenance manual BOS® Cleantec ventilation duct inspection GENERAL REGULATIONS Products covered by this manual have been manufactured in Finland to existing laws, decrees and regulations as stated in the Declaration of Conformity below. · The person who is in charge of machine operation must be acquainted with the construction and operation of the machine and must ensure safe operation.
  • Page 4: Technical Specifications

    Operation and maintenance manual BOS® Cleantec ventilation duct inspection TECHNICAL SPECIFICATIONS Case, Polypropylene Dimensions, mm 480*440*20 Camera cable reel Marine aluminium Control cable LIYY 12x0,25 25m Screen 7”inch LCD color screen, 12 V DC SD Recorder 1 CH mini dvr Memory card SD card max.
  • Page 5 Operation and maintenance manual BOS® Cleantec ventilation duct inspection PROPERLY USE BOS® IR Inspection robots are designed for professional use. The following safety instructions must be taken into account when working: Ø ONLY USE THE DEVICES IN DRY CONDITIONS WITHOUT ANY DANGER OF EXPLOSION! Ø...
  • Page 6 Operation and maintenance manual BOS® Cleantec ventilation duct inspection CONSTRUCTION AND CONTROLS BOS® IR Control Panel Remote contor plug in Robot plug in Audio reg. 7” TFT Colour Screen Battery charging indicator Fuse Indicator Light Charger Plug in Power on/off I/O Camera Switch (Front/Back) Microphone...
  • Page 7: Operating And Safety Instructions

    Operation and maintenance manual BOS® Cleantec ventilation duct inspection OPERATING AND SAFETY INSTRUCTIONS PLEASE CAREFULLY OBSERVE THE FOLLOWING BEFORE AND DURING OPERATION: · The machine user must ensure that the machine is fit for the intended purpose. · The user of the machine must ensure that the voltage and current correspond to the ratings on the CE plate.
  • Page 8 Operation and maintenance manual BOS® Cleantec ventilation duct inspection INSTRUCTIONS 1. Transport The machine must be protected against dirt and moisture during transport. The machine must not be stored outdoors unprotected. Exercise extreme care and caution when moving or lifting the machine. Avoid impacts and knocks during transport and handling.
  • Page 9: Maintenance

    Operation and maintenance manual BOS® Cleantec ventilation duct inspection MAINTENANCE Ø The equipment and cables must be cleaned of dirt and dust after each use! Ø Running water for cleaning is prohibited! Ø Before carrying out maintenance and cleaning work on the device , operating switch must be set to the off position! All maintenance and repair work that requires the protection of the robot, control unit or remote control to be opened must be carried out by an authorized customer service...
  • Page 10: Warranty

    For maintenance or warranty repair, the machine should be sent to the following address: Bierkühl Oy Pellonlaita 1, 50600 Mikkeli Puh. +358 440 178 111 Bierkuhl reserves the right to make changes. SIVU 10 Bierkühl Oy +358 440 178 111 Pellonlaita 1, 50600 Mikkeli Finland www.boscleantec.com...
  • Page 11 Operation and maintenance manual BOS® Cleantec ventilation duct inspection ENVIRONMENT / RECYCLING Ø Waste materials must be disposed of in compliance with the relevant legislative requirements and without harming the environment. Ø A discarded machine or any part of it must not be disposed of together with household waste! Ø...
  • Page 12: Declaration Of Conformity

    Operation and maintenance manual BOS® Cleantec ventilation duct inspection DECLARATION OF CONFORMITY Manufacturer: Bierkühl Oy, Pellonlaita 1 50600 MIKKELI FINLAND Tel.: +358 440 178 111 Website: www.boscleantec.com Product designation: Electric duct cleaning machine Product name: BOS® Clean Intended use: Duct description, inspection and recording Serial number: Year of manufacture:: We hereby declare that the product named above has been designed to comply with the Finnish...