Instruction Manual BC1-24V Sulfuryl Fluoride Battery Pack Charger Service Department (800) 458-6153 ext. 121 (818) 882-2331 ext. 121 FAX (818) 341-0642 E-mail: service@gasdetection.com 01/14/2014 120-00006 REV A PAGE 1 Proprietary and Confidential: This document is the sole property of Interscan Corp. The information contained in this document is confidential and is not to be used, reproduced, or discussed without prior written consent by Interscan Corp.
Page 2
This page intentionally left blank 01/14/2014 120-00006 REV A PAGE 2 Proprietary and Confidential: This document is the sole property of Interscan Corp. The information contained in this document is confidential and is not to be used, reproduced, or discussed without prior written consent by Interscan Corp.
TABLE OF CONTENTS SECTION TITLE PAGE Introduction Battery Charger Principles of Operation Precautions and Proper Care Operation Troubleshooting Determining Internal Impedance Warranty Return Authorization...
Introduction This manual covers the basic function, operation and precautions associated with the The manual should Interscan BC1-24V Sulfuryl Fluoride Battery Pack Charger. be read completely before using the charger! Battery Charger Principles of Operation The battery charger has the universal input range of 100 to 240 VAC (50/60 HZ). Output is 28.8 VDC maximum and 1.5 ADC maximum.
3.0 Operation Plug BC1-24V charger into AC outlet. The LED should come on and immediately have a green color. Connect the battery pack if there are no signs of corrosion. The LED should switch to an amber color. Consult troubleshooting if the LED turns back to green in less than 30 minutes. A fully discharged ("Lo Bat"...
4.1 Determining Internal Impedance Items needed to determine Internal Impedance: 2 - DVM (Digital Voltmeter) use one with a range capable of precisely measuring 27.6 VDC more or less, and the second with a range capable of precisely measuring 10.0 ADC or less. 1 - Stopwatch or timer 1 - 12Ω...
Page 7
Lift the flap on the battery pack case. Note the wiring colors connected to the batteries. Disconnect the two wires connected at the outside of the batteries. This will leave the batteries connected by one wire at the center. Wire the battery pack, DVMs and resistor as shown in Figure 1. Note: One lead from resistor is not connected until test is ready to perform.
Warranty INTERSCAN’s Warranty Policy INTERSCAN CORPORATION warrants portable analyzers of its manufacture (sensors, batteries, fuses, lamps, tubing, fittings, filters, and scrubbers excepted) to be free from defects in material and workmanship for a period of one year from date of shipment.
Should return of the analyzer or part be advised by the Service Department, the "RETURN AUTHORIZATION NUMBER" will expedite prompt return of the repaired unit. For service information, please contact: INTERSCAN CORPORATION Service Department (800) 458-6153 ext. 121 (818) 882-2331 ext. 121 FAX (818) 341-0642 E-mail: service@gasdetection.com...