Download Print this page

Advertisement

Quick Links

User Manual for
Laser Scaler

Advertisement

loading

Summary of Contents for QYSEA V6 Series

  • Page 1 User Manual for Laser Scaler...
  • Page 2: Table Of Contents

    Contents Packing list·······································································································································01 Safety Rules·····································································································································02 Product specification······················································································································03 Usage instructions··························································································································04 Installation······································································································································05 Operation········································································································································10 Maintenance and after-sales support···························································································· 14 Disclaimer········································································································································15...
  • Page 3: Packing List

    / Introduction and Packing List Serial Item Name Quantity Unit Number Laser Scaler Bracket M3*8 Hex Socket Head Cap Screws User manual...
  • Page 4: Safety Rules

    /Safety Rules Before operating FIFISH products, please be sure to receive relevant training and take practices, and read this document thoroughly before performing underwater operations. Operations in violation of QY safety rules may result in the consequence that your safety and interests cannot be guaranteed. 1.Regarding the damages to accessories and underwater vehicle caused by unauthorized modification, disassembly or opening in violation of regulations, or damages to accessories and underwater vehicle caused by improper installation, improper use or operations not in accordance with official regulations, QY doesn’t...
  • Page 5: Product Specification

    / Product Specification Item Specification Laser Tube Type Spot Laser Wavelength 650nm(Red) Scale Length 10cm Wave beam 100 meters Work temperature -5℃~45℃...
  • Page 6: Usage Instructions

    7. Check whether the underwater robot and the remote control are working normally when connected to the connector on the underwater vehicle. 8. Check the batteries of mobile phones, tablet PCs and laptops. 9.After-sales mailbox: support@qysea.com...
  • Page 7: Installation

    /Installation 1. Remove the protective cover of the accessory port at the bottom of the ROV’s body...
  • Page 8 /Installation 1. Remove the protective cover of the accessory port at the bottom of the ROV’s body 1.1 Install bracket into the accessory port and fix it with four M3 screws Laser Scaler Bracket M3*8 Hex Socket Head Cap Screws...
  • Page 9 /Installation 2. Install the Laser Scaler onto the bracket (Please note: the slot of the Laser Scaler must be facing downward to be inserted into the latch of the bracket)
  • Page 10 /Installation 2. Install the Laser Scaler onto the bracket (Please note: the slot of the Laser Scaler must be facing downward to be inserted into the latch of the bracket) 2.1 Fix the Laser Scaler to the bracket with two M3 screws M3*8 Hex Socket Head Cap Screws...
  • Page 11 /Installation 3. Remove the cover of the accessory port under the FIFISH V6 EXPERT, connect the to the cable of the Laser Scaler, and tighten its cap...
  • Page 12: Operation

    /Operation 1. Following integration with the ROV, open the toolbox icon in the APP interface and select the Laser Scaler widget Laser Transmitter Laser Transmitter...
  • Page 13 /Operation 2. The distance between the two points of the laser is 10 cm, which can be used as a reference point for measurements 3. Please ensure the laser points are perpendicular to the object being measured...
  • Page 14 /Operation 4.When then ROV is switched to ‘S’ mode, it will be able to measure objects in multiple angles...
  • Page 15 /Operation 4.When then ROV is switched to ‘S’ mode, it will be able to measure objects in multiple angles...
  • Page 16: Maintenance And After-Sales Support

    WeChat official account (FIFISH Underwater Robot) and the official website. 2. Contact number: +86-755-2266-2313 Working hours: Monday to Friday, 9:00-22:30 (GMT+8) 3. Email: support@qysea.com 4. If there is a machine malfunction, please record the malfunction video in advance, as well as providing the machine SN number and purchase invoice, so that we can provide you with a solution faster.
  • Page 17: Disclaimer

    Failures or damages caused by any third-party products (including products that QYSEA may provide or integrate into QYSEA products at the request of users). Any damage caused by non-QYSEA technology or other support (for example, the support for solving the "operation method" problem or incorrect product settings, installation and firmware upgrades).