Fig. 57: Fitting Wall Insert; Table 46: Tightening Torque (72011) - ABB HT597151 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-M axial
8 Disassembly and assembly / 8.11 Installing the compressor casing
Fitting wall insert
Fig. 57: Fitting wall insert
Product
A170-M
A175-M
Table 46: Tightening torque (72011)
1. Remove lifting device (90190/90195).
2. Slide wall insert (77000) into compressor casing up to stop and remove guide stud
(90319).
3. Secure wall insert with screws (72011) and washers (72008).
For assembly of the alternative air inlet, see section Lufteintritte anbauen.
See also
2 Installing the air inlets [} 87]
© Copyright 2020 ABB. All rights reserved.
Size
Tightening torque [Nm]
M20
M24
HZTL4033_EN
580
1000
Rev.E
May 2020