Summary of Contents for FLTR Tekleen GB6-B

  • Page 2 ☐The filter should be oriented so that the unfiltered media source is directed to the inlet, the manifold closest to the cover. The outlet, the manifold closest to the flush line is the source of filtered media. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 3 GB6-B USERS’ MANUAL For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 4: Table Of Contents

    Controller Configuration/Flush Cycle Counter Differential Pressure Setting SECTION V: USER CONNCECTIONS 5.1 PD 5.2 Valves SECTION VI: GENERAL NOTES 6.1 Installation 6.2 Battery Power Supply Warranty For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 5: Section I: Introduction

    Note: The 'RESET' button on the front panel must be pushed for the change to take effect. Use a blunt object to press the button recessed under the front panel. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 6: Section Iv: Front Panel Controls & Settings

    Button (Scrolls through (Starts a manual function screens) flush/Decreases values) Adjust+ Button Select Button (Increases values) (Selects values in a function) Figure 2 Controller Front Panel For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 7: Status Screen

    2nd filter begins flushing. Press SEL. and then ADJ+ or ADJ- to set the value. It is recommended that the user set this value in a range of 5 to 10 seconds. DWELL 5 SECONDS For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 8: Periodic Time

    Displayed when Jumper 000000 CYCLES is installed across A-B. TWO STATIONS Displayed when Jumper 000000 CYCLES is installed across B-C. CLEAR COUNT Y N 000000 CYCLES For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 9: Differential Pressure Setting

    You may cover the contact points with silicone or any water sealant to prevent shorting. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 10: Valves

    It is recommend that batteries be replaced annually to prevent unexpected usage disruptions. Note: Changing the batteries or pressing the reset button will clear backwash cycle counter and user settings. For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...
  • Page 11: Warranty

    For more information: WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: info@FLTR.com.au SKYPE: Purple.Engineering...