Cooper Wiring Devices AD130 Quick Start Manual

Cooper Wiring Devices AD130 Quick Start Manual

Rfldm lamp module

Advertisement

Quick Links

RFLDM
LAMP MODULE
This plug-in Lamp Module is designed to work with our Passive Infrared Detectors
SP103 and Door/Window Detectors SM103, serving as a receiver. The AD130
plug-in Lamp Module is a Z-Wave
TM
any Z-Wave
enabled network. Z-Wave
TM
Z-Wave
logo can also be used with it regardless of the manufacturer, and ours
can also be used in other manufacturer's Z-Wave
of the Lamp module on other manufacturer's Wireless Controller menu allows
remote On/Off control and dimming of lamps connected.
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure
that the signal is received by its intended destination by routing the signal around
obstacles and radio dead spots.
TM
Adding to Z-Wave
Network
In the side of the casing, there is an On/Off/Dim knob which is used to carry out
inclusion, exclusion or association. Put a Z-Wave
inclusion/exclusion mode, press the knob on the module to complete the
inclusion/exclusion process.
Installation
1. Plug this Lamp module into a wall outlet near the lamp to be controlled.
2. Plug the lamp into the Lamp module. Make sure the lamp to be controlled
cannot exceed 200 watts.
3. Turn the knob or switch on the lamp to the ON position.
4. To manually turn ON the AD130 Lamp Module, press and release the On/Off
knob. The red indicator LED will turn ON, and the lamp plugged into the AD130
TM
enabled device and is fully compatible with
TM
enabled devices displaying the
TM
enabled networks. Inclusion
Each module is
TM
Wireless Controller into
Lamp module will also turn ON.
5. To manually turn OFF the AD130 Lamp Module, simply press and release the
On/Off knob. The red indicator LED will turn OFF and the lamp plugged into
the AD130 Lamp Module will also turn OFF.
6. To manually dim the AD130 Lamp Module, press and hold the On/Off knob
until the desired lighting level has been reached.
7. If Passive Infrared Detector SP103 or Door/Window Detector SM103 has been
removed from the wall by triggering the tamper switch, the Detector (SP103 or
SM103) will send an alarm command (ALARM_REPORT, Alarm Type ==
0x01, Alarm Level == 0x11) to the AD130 Lamp Module, of which red
indicator LED and the lamp plugged into the AD130 Lamp module will flash for
10 seconds simultaneously.
Programming
The On/Off/Dim knob allows the user
-
Turn on, off or dim the lamp attached
-
Include or exclude the module from the Z-Wave
TM
-
Control other Z-Wave
See the instructions for SP103 Passive Infrared Detector or SM103 Door/Window
Detector.
Troubleshooting
Symptom
The Module not working and
LED off
The Module LED illuminating,
but cannot control the ON/OFF
Switch of the lamp attached
The Module LED illuminating,
but the Detector cannot control
the Module
1
TM
system
enabled devices
Cause of Failure
Recommendation
1. The Module is not
1. Check power connections
plugged into the
2. Don't open up the Module and
electrical outlet
send it for repair.
properly
2. The Module is out of
order
Check if the lamp plugged
Replace a new lamp
into the Module has
burned out
1. Not carry out
1. Carry out association
association
2. Wait for a while to re-try
2. Frequency interference

Advertisement

loading

Summary of Contents for Cooper Wiring Devices AD130

  • Page 1 3. Turn the knob or switch on the lamp to the ON position. the Module 2. Frequency interference 4. To manually turn ON the AD130 Lamp Module, press and release the On/Off knob. The red indicator LED will turn ON, and the lamp plugged into the AD130...
  • Page 2 Specification this equipment. This transmitter must not be co-located or operating in conjunction with Operating Voltage 120V/60Hz Maximum Load 300W, for incandescent lamps only any other antenna or transmitter. Minimum Load 25W, for incandescent lamps only Range Minimum 100 feet line of sight IMPORTANT NOTE: Frequency Range 908.42 MHz...