CONTENTS – DV-340N 12 CFM PLATINUM BEAST VACUUM PUMP
Introduction
Motor Specifications
Operation
Pump Maintenance
Repair
Troubleshooting
Return for Repair
Warranty
Lift ring for easier hoisting
Angled easy access 1/4", 3/8" or 1/2" intake tee
Gas ballast for extended oil life
Illuminated low profile
rocker switch
1 HP DC motor with
broad operating
voltage range
Four point stable base
WARNING: UNIT DRAINED OF OIL
FOR SHIPMENT. DO NOT OPERATE
WITHOUT ADDING OIL.
2
2
2
2
3
4
4
4
All metal construction with finned aluminum
housing for heat dissipation, brass fittings and
stainless steel valving
Ergonomic 1/2" NPT break resistant handle
Oil mist filter
controls exhaust
DV-340N PLATINUM
OPERATING MANUAL
Large diameter oil fill opening
Large oil level sight glass
O-ring sealed oil drain
valve to prevent leaks
BEAST 12 CFM VACUUM PUMP
®
CFM 12 CFM (340 l/m)
MOTOR 1 HP, DC
VOLTAGE 115v/230v
INTAKE PORT 1/2" x 1/4" x 3/8"
OIL CAPACITY 32 oz
WEIGHT 34 lb

Advertisement

Table of Contents
loading

Summary of Contents for JB PLATINUM BEAST DV-340N

  • Page 1 CONTENTS – DV-340N 12 CFM PLATINUM BEAST VACUUM PUMP Introduction Motor Specifications Operation Pump Maintenance Repair Troubleshooting Return for Repair Warranty Ergonomic 1/2" NPT break resistant handle Lift ring for easier hoisting Angled easy access 1/4", 3/8" or 1/2" intake tee Oil mist filter controls exhaust Gas ballast for extended oil life...
  • Page 2: Motor Specifications

    If oil level is too low, you will hear air out of the exhaust Figure 2 If oil level is too high, excess oil will be blown out of the exhaust JB INDUSTRIES • 12 CFM PLATINUM BEAST OPERATING MANUAL • 800.323.0811 • SALES@JBIND.COM • JBIND.COM...
  • Page 3 ; use w/PR-208 flexible coupler* PR-41 Splash Guard PR-59 Base PR-307 Filter PR-306 Spacer PR-607 Motor PR-7 Gas ballast valve w/o-ring P90009 O-ring, gas ballast valve JB INDUSTRIES • 12 CFM PLATINUM BEAST OPERATING MANUAL • 800.323.0811 • SALES@JBIND.COM • JBIND.COM...
  • Page 4: Troubleshooting

    PLATINUM Premium, Dual Voltage, and Spark-Proof pumps are warrantied against defects in materials and In the event your pump requires repair, please contact JB Customer Service Department to obtain a ® workmanship for two years OTC—not changing oil will void warranty Return Goods Authorization (RGA) number Ensure that all returned products are packed to avoid any damage in shipment Paperwork should be placed in a separate plastic bag and should include JB’s...
  • Page 5 CONTENIDO – BOMBA DE VACÍO PLATINUM BEAST 12 CFM DV-340N Introducción Especificaciones del motor Funcionamiento Mantenimiento de la bomba Reparación Solución de problemas Devolución para reparación Garantía Mango ergonómico de 1/2" NPT resistente a la rotura Cáncamo de elevación que facilita el levantamiento Pieza de admisión en T angular de acceso El filtro de neblina de aceite fácil de 1/4", 3/8"...
  • Page 6: Especificaciones Del Motor

    Fig. 2 Si el nivel de aceite es demasiado alto, el exceso de aceite saldrá expulsado por el escape JB INDUSTRIES • MANUAL DE INSTRUCCIONES DE PLATINUM BEAST 12 CFM• 800.323.0811 • SALES@JBIND.COM • JBIND.COM...
  • Page 7 Base PR-307 Filtro PR-306 Espaciador PR-607 Motor PR-7 Válvula de lastre de gas con junta tórica P90009 Junta tórica, válvula de lastre de gas JB INDUSTRIES • MANUAL DE INSTRUCCIONES DE PLATINUM BEAST 12 CFM • 800.323.0811 • SALES@JBIND.COM • JBIND.COM...
  • Page 8: Solución De Problemas

    OTC por defectos En caso de que su bomba requiera reparación, contáctese con el servicio de atención al cliente de JB para obtener un ®...
  • Page 9: Manuel D'utilisation

    SOMMAIRE – POMPE À VIDE DV-340N 12 CFM PLATINUM BEAST Introduction Spécifications du moteur Utilisation Maintenance de la pompe Réparation Dépannage Envoi en réparation Garantie Poignée résistante aux chocs 1/2" NPT ergonomique Bague de levage pour faciliter le levage Raccord d’admission en T coudé facile Le filtre à...
  • Page 10: Spécifications Du Moteur

    Si le niveau d’huile est trop bas, vous entendrez l’air sortir de l’échappement Si le niveau d’huile est trop haut, l’huile excédentaire sera chassée par l’échappement JB INDUSTRIES • MANUEL D’UTILISATION 12 CFM PLATINUM BEAST • 800.323.0811 • SALES@JBIND.COM • JBIND.COM...
  • Page 11 PR-59 Socle PR-307 Filtre PR-306 Entretoise PR-607 Moteur PR-7 Vanne de lest de gaz avec joint torique P90009 Joint torique, vanne de lest de gaz JB INDUSTRIES • MANUEL D’UTILISATION 12 CFM PLATINUM BEAST • 800.323.0811 • SALES@JBIND.COM • JBIND.COM...
  • Page 12: Dépannage

    ® devront inclure le numéro RGA spécifié par JB, une description du problème et, s’il y a lieu, tout numéro de commande de de la garantie est perdu si l’huile n’est pas changée La batterie, le chargeur et l’adaptateur CA PLATINUM FLEX sont garantis un ®...

Table of Contents