North American Stinson RCF 2.4 Device Manual

Automated flagger

Advertisement

Quick Links

RCF 2.4
Automated Flagger Assistance
Device Manual
TM
THE LEADER IN TRAFFIC CONTROL SYSTEMS
REV 01 08.29.19

Advertisement

Table of Contents
loading

Summary of Contents for North American Stinson RCF 2.4

  • Page 1 RCF 2.4 Automated Flagger Assistance Device Manual THE LEADER IN TRAFFIC CONTROL SYSTEMS REV 01 08.29.19...
  • Page 2 LIMITED RIGHTS DISCLAIMER REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS 7 Petersburg Circle Port Colborne, Ontario, Canada L3K 5V5 Toll free: 1-877-352-4626 (USA and Canada) Phone: 905-835-0800 Fax: 905-835-0453...
  • Page 4: Safety Precautions

    ECTION • • • • • • • • Safety Precautions...
  • Page 5: Acid Burns

    ECTION Gas Explosion or Fire Acid Burns Electrical Burns...
  • Page 6: Radio Remote Control

    ECTION AFAD – Radio Remote Control – MUTCD – Cycle – Gate Arm – Phase –...
  • Page 7: Solar Panel

    ECTION 1. Solar Panel • • • 2. LED Signal Lamps and Housing • • • • •...
  • Page 8 ECTION 3. Communication Link (Radio Transceiver) • • • Folding Gate Arm • • • • • • 5. Power Supply • • • Solar Panel ECTION 6. Trailer Section Components • •...
  • Page 9 ECTION 1. Auxiliary Holder: 2. Gate Arm Holder: 3. STOP HERE ON RED Sign Holder: Spare Tire Mount (Optional add-on item): 5. Running Light Cable:...
  • Page 10 ECTION 1. Controller 2. Wiring Conduit 3. Terminal Block Main Power On/Off Switch 5. Battery Charger 6. Solar Controller/Regulator 7. Fuse Block 8. Isolated Power Distribution Studs...
  • Page 11 ECTION WARNING The jacks must be lowered as outlined CAUTION...
  • Page 12 ECTION CAUTION Ensure all jacks are deployed and the unit is WARNING WARNING The jacks must be lowered as outlined ALWAYS check for overhead power lines or utility lines in the immediate area to avoid CAUTION Use care when removing the tongue as it is...
  • Page 13 ECTION WARNING to do so may result in injury or death due to WARNING to do so may result in injury or death due to...
  • Page 14 ECTION...
  • Page 15 ECTION CAUTION • • • • •...
  • Page 16: Soft Buttons

    ECTION Gen 3 Controller 1. Soft Buttons 2. BACK Button ALERT BACK ENTER ALERT BUSY BUSY www.NorthAmericaTra c.com ENTER Button 5. Directional Buttons 6. USB Port 7. J-Plugs (J1/J2) 8. Serial Port (J0) 9. Speaker...
  • Page 17: Radio Channel

    ECTION DEFAULT ALL RED FEB/01/17 09:53AM PRESS START TO RESUME PROGRAM: MODEL V## BATTERY: 24.0 VOLTS HOME UNIT: PRIMARY RADIO CHANNEL: 03 RADIO SIGNAL: 1. System Feedback 2. Battery Voltage Radio Channel 5. Radio Signal Strength 6. Menu Path 7. Program Version 8.
  • Page 18: Radio Signal

    ECTION DEFAULT FLASH RED FEB/01/17 09:53AM PRESS START TO RESUME PROGRAM: AFAD V## BATTERY: 24.0 VOLTS HOME > OPTIONS PG 1 UNIT: PRIMARY RADIO CHANNEL: 03 RADIO SIGNAL: UNIT ID PRIMARY RADIO CHANNEL ONE-WAY ZONE SITE LAYOUT TWO UNITS LOCK GATE ARM SOFTWARE INTRUSION...
  • Page 19: Intrusion Alarm

    ECTION DEFAULT ALL RED DEFAULT ALL RED FEB/01/17 09:53AM FEB/01/17 09:53AM PRESS START TO RESUME PRESS START TO RESUME PROGRAM: AFAD V## PROGRAM: AFAD V## BATTERY: 24.0 VOLTS HOME BATTERY: 24.0 VOLTS HOME UNIT: PRIMARY RADIO CHANNEL: 03 RADIO SIGNAL: UNIT: SECONDARY 1 RADIO CHANNEL: 03 RADIO SIGNAL:...
  • Page 20: Communication Settings

    ECTION Lamp Outputs – Back Lamp – DEFAULT FLASH RED FEB/01/17 09:53AM PRESS START TO RESUME PROGRAM: AFAD V## BATTERY: 24.0 VOLTS HOME > OPTIONS PG 2 UNIT: PRIMARY RADIO CHANNEL: 03 RADIO SIGNAL: PREV CONTROL MODE MANUAL PAGE FAULT LOGS LAMP OUTPUTS COMMUNICATION LOCK...
  • Page 21: Factory Settings

    ECTION Factory Settings – Set Model – Display Dimming – Start Program – DEFAULT ALL RED FEB/01/17 09:53AM PRESS START TO RESUME PROGRAM: AFAD V## BATTERY: 24.0 VOLTS HOME UNIT: PRIMARY RADIO CHANNEL: 03 RADIO SIGNAL: OPERATOR SHALL BE FULLY TRAINED OPERATOR SHALL B Sync Radio Remote –...
  • Page 22: Primary Setup

    ECTION Secondary Setup DEFAULT ALL RED DEFAULT FLASH RED FEB/01/17 09:53AM FEB/01/17 09:53AM PRESS START TO RESUME PRESS START TO RESUME PROGRAM: AFAD V## PROGRAM: AFAD V## BATTERY: 24.0 VOLTS HOME BATTERY: 24.0 VOLTS HOME > OPTIONS PG 1 UNIT: SECONDARY 1 RADIO CHANNEL: 03 RADIO SIGNAL: UNIT: SECONDARY 1...
  • Page 23: Control Mode

    ECTION Layout Units Required Control Mode One-Way Zone - Single Unit One-Way Zone - Two Unit Two-Way Zone (Manual Mode)
  • Page 24 ECTION...
  • Page 25 ECTION...
  • Page 26 ECTION Radio Remote Push Buttons: Radio Remote Push Buttons Functions: • • • • Radio Remote Power supply: Weak Battery Indicator:...
  • Page 27: Setting The Radio Channel

    ECTION Setting the Radio Channel: DEFAULT FLASH RED FEB/01/17 09:53AM PRESS START TO RESUME PROGRAM: AFAD V ## BATTERY: 24.0 VOLTS HOME UNIT: PRIMARY RADIO CHANNEL: 03 RADIO SIGNAL: CHANGE TIMING START SYNC RADIO REMOTE 1.) Press and hold the RED and BLACK buttons on the radio remote.
  • Page 28 ECTION Gen 1 - Portable Traffic Signal Controller STOP FLASH MENU DISTANCE GREEN MASTER (SEC) (SEC) (VOLTS) MODE 12.4 12.5 TIME CONTROL AMBER PH 2/3 PH 2/3 SECONDARY (VOLTS) TIME GREEN (SEC) (SEC) (SEC) ENTER FULL START SENSOR BACK STATUS LIGHTS POWER LIGHT...
  • Page 29 ECTION 6. Refer to S ECTION ETTING GEN 3 SETUP GEN 1 Secondary Unit ID's SITE LAYOUT ONE-WAY ZONE - TWO UNITS TWO-WAY ZONE (MANUAL MODE) TWO-WAY 1 SIDE ROAD TWO-WAY 1 CROSS ROAD TWO-WAY 2 SIDE ROADS TWO-WAY 2 CROSS ROADS TWO-WAY 3 SIDE TWO-WAY 4 SIDE...
  • Page 30: Exporting Logs

    ECTION 10.1 15 T ECTION ROUBLESHOOTING DEFAULT FLASH RED FEB/01/17 09:53AM PRESS START TO RESUME PROGRAM: MODEL V## • BATTERY: 24.0 VOLTS HOME > OPTIONS 1 > FAULT LOGS UNIT: PRIMARY RADIO CHANNEL: 03 RADIO SIGNAL: • PREV CLEAR FAULT PAGE •...
  • Page 31: Diagnostic Screen

    ECTION Viewing Exported Fault and Data Logs in a Spreadsheet: • • • 10.2 OPTIONS HELP SEC1 Diagnostic Screen: DEFAULT FLASH RED FEB/01/17 09:53AM PRESS START TO RESUME PROGRAM: AFAD V## BATTERY: 24.0 VOLTS HOME > DIAGNOSTIC UNIT: PRIMARY RADIO CHANNEL: 03 RADIO SIGNAL: •...
  • Page 32 ECTION Phase Status (PHZ): DEFAULT FLASH RED CURRENT PHASE FEB/01/17 09:53AM PRESS START TO RESUME PROGRAM: MODEL V## BATTERY: 24.0 VOLTS HOME > PHZ STATUS UNIT: PRIMARY RADIO CHANNEL: 03 RADIO SIGNAL: TIME PHASE STATUS CURRENT PHASE PRIMARY NEXT PHASE TIME 3 SECONDS NEXT PHASE...
  • Page 33 ECTION 11.1 • • • • • • Cellular Satellite & Coverage (Geo-Fencing) 11.2 • • •...
  • Page 34 ECTION Application...
  • Page 35: Dip Switch Settings

    ECTION 12.1 Best Practices: • • Common Interference: • • • • Dip Switch Settings: 12.2 Where it is required: • • Cable Requirements: • • • •...
  • Page 36 ECTION 13.1 Importance of Sun Exposure Cleaning 13.2 Autonomy Flooded Lead Acid (FLA): Sealed Lead Acid (AGM): Temperature High...
  • Page 37: Section 13.4 Generator

    ECTION Over Discharge Inactivity to S 13.4 G ECTION ENERATOR Battery Threshold states: Dead Blackout 13.3 13.4 G ECTION ENERATOR 13.4 Connection and Operation...
  • Page 38 ECTION...
  • Page 39 ECTION...
  • Page 40 ECTION...
  • Page 41 ECTION...
  • Page 42 ECTION...
  • Page 43 ECTION...
  • Page 44 ECTION Part Name Part Number 500-0676 500-0691 500-0692 500-0737 500-0064 500-0070 500-0182 800-0480 500-0003 400-0146 400-0416 500-0092 500-0995 500-0782 500-0673 500-0149 500-0731 400-0419 500-0377 500-0119 100-0076 500-0262 500-0235 800-0227 800-0226 500-0981 500-0055 500-0608 300-0095 300-0093 100-0086 100-0085 500-0168 400-0212 400-0213 500-0990 500-0001 400-0272...