Advertisement

Quick Links

SPLIT-TYPE ROOM AIR CONDITIONER
Owner's Manual &
Installation Manual
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.
Please check the applicable models, technical
data, F-GAS(if any) and manufacturer information
from the "Owner's Manual - Product Fiche "
in the packaging of the outdoor unit.
(European Union products only)

Advertisement

Table of Contents
loading

Summary of Contents for LAMINOX FSHQUADRI28HFN8

  • Page 1 SPLIT-TYPE ROOM AIR CONDITIONER Owner’s Manual & Installation Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. Please check the applicable models, technical data, F-GAS(if any) and manufacturer information from the “Owner's Manual - Product Fiche ”...
  • Page 2: Table Of Contents

    Table of Contents Safety Precautions ................03 Owner’s Manual Unit Specifications and Features ............07 1. Indoor unit display.........................07 2. Operating temperature........................08 3. Other features ..........................09 4. Setting angle of airflow.........................10 5. Manual operation (without Remote)....................10 Care and Maintenance ..............11 Troubleshooting .................13...
  • Page 3 Installation Manual Accessories ..................16 Installation Summary - Indoor Unit ..........17 Unit Parts .....................18 Indoor Unit Installation ..............19 1. Select installation location......................19 2. Attach mounting plate to wall......................19 3. Drill wall hole for connective piping....................20 4. Prepare refrigerant piping.......................21 5. Connect drain hose........................21 6.
  • Page 4: Safety Precautions

    Safety Precautions Read Safety Precautions Before Operation and Installation Incorrect installation due to ignoring instructions can cause serious damage or injury. The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION. WARNING CAUTION This symbol indicates the possibility of This symbol indicates the possibility property damage or serious consequences.
  • Page 5 CLEANING AND MAINTENANCE WARNINGS Turn off the device and disconnect the power before cleaning. Failure to do so can cause • electrical shock. Do not clean the air conditioner with excessive amounts of water. • Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents •...
  • Page 6: Owner's Manual

    WARNINGS FOR PRODUCT INSTALLATION 1. Installation must be performed by an authorized dealer or specialist. Defective installation can cause water leakage, electrical shock, or fire. 2. Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire. (In North America,installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only.) 3.
  • Page 7 WARNING for Using R32/R290 Refrigerant When flammable refrigerant are employed, appliance shall be stored in a well -ventilated area where the room size corresponds to the room area as specifiec for operation. For R32 frigerant models: Appliance shall be installed, operated and stored in a room with a floor area larger than 4m . Appliance shall not be installed in an unvertilated space, if that space is smaller than 4m .
  • Page 8: Unit Specifications And Features

    Unit Specifications and Features Indoor unit display NOTE: Different models have different front panel and display window. Not all the indicators describing below are available for the air conditioner you purchased. Please check the indoor display window of the unit you purchased. Illustrations in this manual are for explanatory purposes.
  • Page 9: Operating Temperature

    Operating temperature When your air conditioner is used outside of the following temperature ranges, certain safety protection features may activate and cause the unit to disable. Inverter Split Type FOR OUTDOOR UNITS COOL mode HEAT mode DRY mode WITH AUXILIARY 17°C - 32°C 0°C - 30°C 10°C - 32°C...
  • Page 10: Other Features

    Sleep Operation • A guide on using the infrared remote is not The SLEEP function is used to decrease included in this literature package. Not all energy use while you sleep (and don’t the functions are available for the air need the same temperature settings to conditioner, please check the indoor display stay comfortable).
  • Page 11: Setting Angle Of Airflow

    Setting Angle of Air Flow • Setting vertical angle of air flow While the unit is on, use the SWING/DIRECT button on remote control to set the direction (vertical angle) of airflow. Please refer to the Remote Control Manual for details. NOTE ON LOUVER ANGLES When using COOL or DRY mode, do not set louver at too vertical an angle for long periods...
  • Page 12: Care And Maintenance

    Care and Maintenance Rinse the filter with fresh water, then shake Cleaning Your Indoor Unit off excess water. BEFORE CLEANING OR Dry it in a cool, dry place, and refrain from MAINTENANCE exposing it to direct sunlight. ALWAYS TURN OFF YOUR AIR CONDITIONER When dry, re-clip the air freshening filter to the larger filter, then slide it back into the SYSTEM AND DISCONNECT ITS POWER SUPPLY...
  • Page 13 Maintenance – CAUTION Long Periods of Non-Use Before changing the filter or cleaning, • If you plan not to use your air conditioner for an turn off the unit and disconnect its power extended period of time, do the following: supply.
  • Page 14: Troubleshooting

    Troubleshooting SAFETY PRECAUTIONS If ANY of the following conditions occurs, turn off your unit immediately! The power cord is damaged or abnormally warm • You smell a burning odor • The unit emits loud or abnormal sounds • A power fuse blows or the circuit breaker frequently trips •...
  • Page 15 Issue Possible Causes The outdoor unit The unit will make different sounds based on its current operating mode. makes noises Dust is emitted from The unit may accumulate dust during extended periods of non-use, which will be either the indoor or emitted when the unit is turned on.
  • Page 16 Problem Possible Causes Solution Wait for the power to be restored Power failure The power is turned off Turn on the power The unit is not The fuse is burned out Replace the fuse working Replace batteries Remote control batteries are dead The Unit’s 3-minute protection Wait three minutes after restarting has been activated...
  • Page 17: Accessories

    Accessories The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock and fire, or cause the equipment to fail. The items are not included with the air conditioner must be purchased separately.
  • Page 18: Installation Summary - Indoor Unit

    Installation Summary - Indoor Unit 15cm (5.9in) 12cm 12cm (4.75in) (4.75in) 2.3m (90.55in) Attach Mounting Plate Select Installation Location Determine Wall Hole Position Drill Wall Hole Connect Piping Connect Wiring (not applicable for some locations in the US ) Wrap Piping and Cable Prepare Drain Hose (not applicable for some locations in the US ) STEP...
  • Page 19: Unit Parts

    Unit Parts NOTE: The installation must be performed in accordance with the requirement of local and national standards. The installation may be slightly different in different areas. Air-break switch (1) (2) Functional Filter (On Back of Remote Controller Wall Mounting Plate Main Filter - Some Units) Remote controller Holder Front Panel...
  • Page 20: Indoor Unit Installation

    Indoor Unit Installation NOTE ABOUT WALL HOLE: Installation Instructions – Indoor unit If there is no fixed refrigerant piping: PRIOR TO INSTALLATION While choosing a location, be aware that you Before installing the indoor unit, refer to the should leave ample room for a wall hole (see label on the product box to make sure that the Drill wall hole for connective piping step) model number of the indoor unit matches the...
  • Page 21: Drill Wall Hole For Connective Piping

    Step 3: Drill wall hole for connective piping 1. Determine the location of the wall hole based on the position of the mounting plate. Refer to Mounting Plate Dimensions. 2. Using a 65mm (2.5in) or 90mm(3.54in) Type A (depending on models )core drill, drill a Type B hole in the wall.
  • Page 22: Prepare Refrigerant Piping

    Step 5: Connect drain hose Step 4: Prepare refrigerant piping By default, the drain hose is attached to the left- The refrigerant piping is inside an insulating hand side of unit (when you’re facing the back sleeve attached to the back of the unit. You of the unit).
  • Page 23: Connect Signal Cable

    WARNING BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE BEFORE PERFORMING ANY ELECTRICAL REGULATIONS OR WIRING WORK, TURN OFF THE MAIN POWER TO THE SYSTEM. 1. All wiring must comply with local and national electrical codes, regulations and must be Step 6: Connect signal cable installed by a licensed electrician.
  • Page 24: Wrap Piping And Cables

    pen front panel of the indoor unit. 1. O NOTE ABOUT WIRING Using a screwdriver, open the wire box cover THE WIRING CONNECTION PROCESS MAY on the right side of the unit. This will reveal DIFFER SLIGHTLY BETWEEN UNITS AND the terminal block.
  • Page 25: Mount Indoor Unit

    Step 8: Mount indoor unit Connect drain hose and refrigerant piping (refer to Refrigerant Piping Connection If you installed new connective piping to the section of this manual for instructions). outdoor unit, do the following: Keep pipe connection point exposed to If you have already passed the refrigerant perform the leak test (refer to Electrical piping through the hole in the wall, proceed...
  • Page 26: Outdoor Unit Installation

    Outdoor Unit Installation Install the unit by following local codes and install unit in the following locations: DO NOT regulations , there may be differ slightly between different regions. Near an obstacle that will block air inlets and outlets Near a public street, crowded areas, or where noise from the unit will disturb others Near animals or plants that will be harmed by hot air discharge...
  • Page 27: Install Drain Joint

    Step 2: Install drain joint(Heat pump unit only) Step 3: Anchor outdoor unit Before bolting the outdoor unit in place, you must The outdoor unit can be anchored to the install the drain joint at the bottom of the unit. ground or to a wall-mounted bracket with Note that there are two different types of drain bolt(M10).
  • Page 28 Outdoor Unit Dimensions (mm) Mounting Dimensions Distance A (mm) Distance B (mm) W x H x D 681x434x285 (26.8”x17.1”x11.2”) 460 (18.1”) 292 (11.5”) 700x550x270 (27.5”x21.6”x10.6”) 450 (17.7”) 260 (10.2”) 450 (17.7”) 260 (10.2”) 700x550x275 (27.5”x21.6”x10.8”) 255 (10.0”) 720x495x270 (28.3”x19.5”x10.6”) 452 (17.7”) 452 (17.8”) 302(11.9”) 728x555x300 (28.7”x21.8”x11.8”)
  • Page 29: Connect Signal And Power Cables

    Step 4: Connect signal and power cables 2. Unscrew the electrical wiring cover and remove it. The outside unit’s terminal block is protected by 3. Unscrew the cable clamp below the terminal an electrical wiring cover on the side of the unit. block and place it to the side.
  • Page 30: Refrigerant Piping Connection

    Refrigerant Piping Connection When connecting refrigerant piping, do not let substances or gases other than the specified refrigerant enter the unit. The presence of other gases or substances will lower the unit’s capacity, and can cause abnormally high pressure in the refrigeration cycle. This can cause explosion and injury.
  • Page 31: Remove Burrs

    Step 2: Remove burrs PIPING EXTENSION BEYOND FLARE FORM Burrs can affect the air-tight seal of refrigerant Outer Diameter of A (mm) piping connection. They must be completely Max. Pipe (mm) Min. Max. removed. Ø 6.35 (Ø 0.25”) 0.7 (0.0275”) 1.3 (0.05”) Hold the pipe at a downward angle to prevent Ø...
  • Page 32 Tighten the flare nut as tightly as possible by hand. Using a spanner, grip the nut on the unit tubing. While firmly gripping the nut on the unit tubing, use a torque wrench to tighten the flare nut according to the torque values in the Torque Requirements table below.
  • Page 33: Air Evacuation

    Air Evacuation If there is a change in system pressure, refer Preparations and Precautions to Gas Leak Check section for information Air and foreign matter in the refrigerant circuit can on how to check for leaks. If there is no cause abnormal rises in pressure, which can damage change in system pressure, unscrew the cap from the packed valve (high pressure valve).
  • Page 34: Note On Adding Refrigerant

    Note on Adding Refrigerant Some systems require additional charging depending on pipe lengths. The standard pipe length varies according to local regulations. For example, in North America, the standard pipe length is 7.5m (25’). In other areas, the standard pipe length is 5m (16‘). The refrigerant should be charged from the service port on the outdoor unit’s low pressure valve.
  • Page 35: Electrical And Gas Leak Checks

    Electrical and Gas Leak Checks Before Test Run WARNING – RISK OF ELECTRIC SHOCK Only perform test run after you have completed ALL WIRING MUST COMPLY WITH LOCAL the following steps: AND NATIONAL ELECTRICAL CODES, Electrical Safety Checks – Confirm that •...
  • Page 36: Test Run

    Test Run DOUBLE-CHECK PIPE CONNECTIONS Test Run Instructions During operation, the pressure of the You should perform the Test Run for at least 30 refrigerant circuit will increase. This may minutes. reveal leaks that were not present during your Connect power to the unit. initial leak check.
  • Page 37 Impedance Information (Applicable to the following units only) This appliance MSAFB-12HRN1-QC6 can be connected only to a supply with system impedance no more than 0.373 . In case necessary, please consult your supply authority for system impedance information. This appliance MSAFD-17HRN1-QC5 can be connected only to a supply with system impedance no more than 0.210 .
  • Page 38 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version.
  • Page 39 AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION Thank you very much for purchasing our air conditioner. Please read this owner's manual carefully before using your air conditioner. Make sure to save this manual for future reference.
  • Page 40 CONTENTS Remote controller Specifications........... Operation buttons ................Indicators on LCD ................How to use the buttons ..............Auto operation................. Cooling/Heating/Fan operation............Dehumidifying operation ............... Adjusting air flow direction............Timer operation................Handling the remote controller ............NOTE: Buttons design is based on typical model and might be slightly different from the actual one you purchased,the actual shape shall prevail.
  • Page 41: Remote Controller Specifications

    Remote Controller Specifications Model RG57A3/BGEF, RG57A2/BGEF, RG57B/BGE,RG57D/BGE 3.0V(Dry batteries R03/LR03×2) Rated Voltage Signal Receiving Range Environment -5 C~60 C ON/OFF ON/OFF SHORT SHORT TIMER TIMER MODE MODE TEMP TEMP TIMER TIMER SLEEP FRESH SLEEP FRESH SWING DIRECT TURBO TURBO SELF CLEAN LED FOLLOW ME RG57A2/BGEF RG57B/BGE...
  • Page 42: Operation Buttons

    Operation of buttons ON/OFF Button This button turns the air conditioner ON and OFF. MODE Button Press this button to modify the air conditioner mode in a sequence of following: HEAT AUTO COOL NOTE:Please do not select HEAT mode if the machine you purchased is cooling only type.
  • Page 43 Operation of buttons UP Button( Push this button to increase the indoor temperature setting in 1 C increments to 30 C. DOWN Button( Push this button to decrease the indoor temperature setting in 1 C increments to 17 C. NOTE:Temperature contol is not available in Fan mode.
  • Page 44 Operation of buttons Swing Button (applicable to RG57(A2)A3/BGEF) Used to stop or start vertical louver movement and set the desired left/right air flow direction. The vertical louver changes 6 degree in angle for each press. And the temperature display area of indoor unit displays for one second.
  • Page 45: Indicators On Lcd

    Indicators on LCD Information are displayed when Mode display the remote controller is powered AUTO COOL HEAT Displayed when data transmitted. Displayed when remote controller is ON. Battery display(low battery detection) Not available for this unit Displayed when TIMER ON time is set. Displayed when TIMER OFF time is set.
  • Page 46: How To Use The Buttons

    How to use the buttons Auto operation Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing. 1. Press the MODE button to select Auto. 2. Press the UP/DOWN button to set the desired temperature.
  • Page 47: Dehumidifying Operation

    How to use the buttons Dehumidifying operation Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing. 1. Press the MODE button to select DRY mode. 2. Press the UP/DOWN buttons to set the desired temperature.
  • Page 48: Timer Operation

    Timer operation Press the TIMER ON button can set the auto-on time of the unit. Press the TIMER OFF button can set the auto-off time of the unit. To set the Auto-on time. 1. Press the TIMER ON button. The remote controller shows TIMER ON, the last Auto-on setting time and the signal "H"...
  • Page 49 CAUTION When you select the timer operation, the remote controller automatically transmits the timer signal to the indoor unit for the specified time. Therefore, keep the remote controller in a location where it can transmit the signal to the indoor unit properly. The effective operation time set by the remote controller for the timer function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13, 14, 15,16,17, 18, 19, 20,...
  • Page 50 TIMER OFF (Auto-off Operation) The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed. The air conditioner will stop automatically at the set time. Example: Stop To stop the air conditioner in 10 hours. 1.
  • Page 51 TIMER ON → TIMER OFF (Off → Start → Stop operation) This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house. Example: Start To start the air conditioner 2 hours after setting, Stop and stop it 5 hours after setting.
  • Page 52: Handling The Remote Controller

    Handling the remote controller Location of the remote controller. Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep. CAUTIONS The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit.
  • Page 53 Replacing batteries The following cases signify exhausted batteries. Replace old batteries with new ones. Receiving beep is not emitted when a signal is transmitted. Indicator fades away. The remote controller is powed by two dry batteries (R03/LR03X2) housed in the back rear part and protected by a cover.
  • Page 54 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

This manual is also suitable for:

Fshm30-27nf818hfn8

Table of Contents