Repair and Maintenance
PCB guarantees Total Customer Satisfaction through its
"Lifetime Warranty Plus" on all Platinum Stock Products
sold by PCB and through its limited warranties on all other
PCB Stock, Standard and Special products. Due to the
sophisticated nature of our sensors and associated
instrumentation, field servicing and repair is not
recommended and, if attempted, will void the factory
warranty.
Beyond routine calibration and battery replacements
where applicable, our products require no user
maintenance. Clean electrical connectors, housings, and
mounting surfaces with solutions and techniques that will
not harm the material of construction. Observe caution
when using liquids near devices that are not hermetically
sealed. Such devices should only be wiped with a
dampened cloth—never saturated or submerged.
In the event that equipment becomes damaged or ceases
to operate, our Application Engineers are here to support
your troubleshooting efforts 24 hours a day, 7 days a
week. Call or email with model and serial number as well
as a brief description of the problem.
Calibration
Routine
calibration
of
instrumentation is necessary to maintain measurement
accuracy. We recommend calibrating on an annual basis,
after exposure to any extreme environmental influence,
or prior to any critical test.
PCB Piezotronics is an ISO-9001 certified company whose
calibration services are accredited by A2LA to ISO/IEC
17025, with full traceability to SI through N.I.S.T. In
addition to our standard calibration services, we also offer
specialized tests, including: sensitivity at elevated or
cryogenic temperatures, phase response, extended high
or low frequency response, extended range, leak testing,
hydrostatic pressure testing, and others. For more
information, contact your local PCB Piezotronics
distributor, sales representative, or factory customer
service representative.
Manual 21354 Rev E
ECN 50523
sensors
and
associated
Returning Equipment
If factory repair is required, our representatives will
provide you with a Return Material Authorization (RMA)
number, which we use to reference any information you
have already provided and expedite the repair process.
This number should be clearly marked on the outside of
all returned package(s) and on any packing list(s)
accompanying the shipment.
Contact Information
PCB Piezotronics, Inc.
3425 Walden Ave.
Depew, NY14043 USA
Toll-free: (800) 828-8840
24-hour SensorLine: (716) 684-0001
General inquiries:
info@pcb.com
Repair inquiries:
rma@pcb.com
For a complete list of distributors, global offices and sales
representatives, visit our website, www.pcb.com.
Safety Considerations
This product is intended for use by qualified personnel
who recognize shock hazards and are familiar with the
precautions required to avoid injury. While our equipment
is designed with user safety in mind, the protection
provided by the equipment may be impaired if equipment
is used in a manner not specified by this manual.
Discontinue use and contact our 24-Hour Sensorline if:
Assistance is needed to safely operate equipment
Damage is visible or suspected
Equipment fails or malfunctions
For complete equipment ratings, refer to the enclosed
specification sheet for your product.
Definition of Terms and Symbols
The following symbols may be used in this manual:
DANGER
Indicates an immediate hazardous
situation, which, if not avoided, may
result in death or serious injury.

Advertisement

Table of Contents
loading

Summary of Contents for PCB Piezotronics 261B03

  • Page 1  Assistance is needed to safely operate equipment  PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected  calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
  • Page 2 CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
  • Page 3 PCB工业监视和测量设备 - 中国RoHS2公布表 PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 有害物质 镉 汞 铅 (Pb) 六价铬 (Cr(VI)) 多溴联苯 (PBB) 多溴二苯醚 (PBDE) 部件名称 (Hg) (Cd) 住房 PCB板 电气连接器 压电晶体 环氧 铁氟龙 电子 厚膜基板 电线 电缆 塑料 焊接...
  • Page 4 Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
  • Page 5: Table Of Contents

    3-COMPONENT FORCE LINK OPERATION MANUAL  Table of Contents Section Page Introduction Description Installation Operation Polarity Low Frequency Monitoring Discharge Time Constant Calibration Troubleshooting 10.0 Maintenance Figure Page 3-Component Force Link Axis Definition ICP® 3-Component Force Link Cable Strain Relief Characteristic Discharge Time Constant Curve Step Function Response MANUAL NUMBER:...
  • Page 6: Introduction

    1.0 INTRODUCTION If this should occur, refer to the service and repair document for proper information. PCB Piezotronics 3-component force link sensors are Measurements along the z-axis are proportional to designed to simultaneously measure dynamic and quasi- applied compression, tension, and impact forces.
  • Page 7: Operation

    3-COMPONENT FORCE LINK OPERATION MANUAL  The condition of the mating surfaces can adversely 30 VDC, while the constant current required ranges affect the sensitivity of the sensor. It is essential that all from 2 to 20 surfaces be clean, rigid and perfectly flat to avoid erroneous data.
  • Page 8: Discharge Time Constant

    3-COMPONENT FORCE LINK OPERATION MANUAL  features or zero "clamped" output often necessary in decay. Approximately five DTC intervals are needed repetitive, positive polarity pulse train applications. for a peak signal to naturally decay back to zero. If you wish to learn more about ICP® sensors, consult The rule of thumb for signal discharge, as outlined in PCB's General Signal Conditioning Guide (G-000lE), a Figure 4, is this: for the first 10% of the DTC, the signal...
  • Page 9: Troubleshooting

    3-COMPONENT FORCE LINK OPERATION MANUAL  9.0 TROUBLESHOOTING When a PCB signal conditioner with any of the 10.0 MAINTENANCE following indicators are used, tum the power on and observe the voltmeter ( or LED's) on the front panel. The sensor connector must be kept clean, especially if it is operating in a dusty and/or wet environment.
  • Page 10 All specifications are at room temperature unless otherwise specified. 3425 Walden Avenue, Depew, NY 14043 In the interest of constant product improvement, we reserve the right to change specifications without notice. ® is a registered trademark of PCB Piezotronics, Inc.
  • Page 11 Neither it nor any    reproduction thereof will be disclosed to others 3.150 .001 80.01 DESCRIPTION without the written consent of PCB Piezotronics Inc. UPDATED FOR METRIC & REFERENCE DIMENSIONS 52939    2.362 .001 59.99...

Table of Contents